Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis

被引:4
|
作者
Edmund, Jens M. [1 ,2 ]
Andreasen, Daniel [3 ]
Van Leemput, Koen [3 ,4 ]
机构
[1] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Oncol, Radiotherapy Res Unit, DK-2730 Herlev, Denmark
[2] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2021年 / 18卷
关键词
MRI-only RT; IGRT; Synthetic CT; Pseudo CT; Magnetic resonance imaging; Radiotherapy; Cone beam CT; SYNTHETIC CT GENERATION; RADIATION-THERAPY; NEURAL-NETWORK; MRI SEQUENCES; PSEUDO-CT;
D O I
10.1016/j.phro.2021.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Radiotherapy (RT) based on magentic resonance imaging (MRI) only is currently used clinically in the pelvis. A synthetic computed tomography (sCT) is needed for dose planning. Here, we investigate the accuracy of cone beam CT (CBCT) based MRI-only image guided RT (IGRT) and sCT image quality. Materials and methods: CT, MRI and CBCT scans of ten prostate cancer patients were included. The MRI was converted to a sCT using a multi-atlas approach. The sCT, CT and MR images were auto-matched with the CBCT on the bony anatomy. Paired sCT-CT and sCT-CBCT data were created. CT numbers were converted to relative electron (RED) and mass densities (DES) using a standard calibration curve for the CT and sCT. For the CBCT RED/DES conversion, a phantom and paired CT-CBCT population based calibration curve was used. For the latter, the CBCT numbers were averaged in 100 HU bins and the known RED/DES of the CT were assigned. The paired sCT-CT and sCT-CBCT data were averaged in bins of 10 HU or 0.01 RED/DES. The median absolute error (MeAE) between the sCT-CT and sCT-CBCT bins was calculated. Wilcoxon rank-sum tests were carried out for the IGRT and MeAE study. Results: The mean sCT or MR IGRT difference from CT was <= 2 mm but significant differences were observed. A CBCT HU or phantom-based RED/DES MeAE did not estimate the sCT quality similar to a CT based MeAE but the CBCT population-based RED/DES MeAE did. Conclusions: MRI-only CBCT-based IGRT seems feasible but caution is advised. A MeAE around 0.1 DES could call for sCT quality inspection.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [31] PRETREATMENT ENDORECTAL MAGNETIC RESONANCE IMAGING AND MAGNETIC RESONANCE SPECTROSCOPIC IMAGING FEATURES OF PROSTATE CANCER AS PREDICTORS OF RESPONSE TO EXTERNAL BEAM RADIOTHERAPY
    Joseph, Tim
    McKenna, David A.
    Westphalen, Antonio C.
    Coakley, Fergus V.
    Zhao, Shoujun
    Lu, Ying
    Hsu, I-Chow
    Roach, Mack, III
    Kurhanewicz, John
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (03): : 665 - 671
  • [32] Evaluation of a deep learning magnetic resonance imaging reconstruction method for synthetic computed tomography generation in prostate radiotherapy
    Olsson, Lars E.
    af Wetterstedt, Sacha
    Scherman, Jonas
    Gunnlaugsson, Adalsteinn
    Persson, Emilia
    Gustafsson, Christian Jamtheim
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [33] Accuracy of Image Guidance Using Free-Breathing Cone-Beam Computed Tomography for Stereotactic Lung Radiotherapy
    Kamomae, Takeshi
    Monzen, Hajime
    Nakayama, Shinichi
    Mizote, Rika
    Oonishi, Yuuichi
    Kaneshige, Soichiro
    Sakamoto, Takashi
    PLOS ONE, 2015, 10 (05):
  • [34] DAILY IMAGE GUIDANCE WITH CONE-BEAM COMPUTED TOMOGRAPHY FOR HEAD-AND-NECK CANCER INTENSITY-MODULATED RADIOTHERAPY: A PROSPECTIVE STUDY
    Den, Robert B.
    Doemer, Anthony
    Kubicek, Greg
    Bednarz, Greg
    Galvin, James M.
    Keane, William M.
    Xiao, Ying
    Machtay, Mitchell
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1353 - 1359
  • [35] Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen
    Dal Bello, Riccardo
    Lapaeva, Mariia
    La Greca Saint-Esteven, Agustina
    Wallimann, Philipp
    Gunther, Manuel
    Konukoglu, Ender
    Andratschke, Nicolaus
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [36] Magnetic resonance imaging versus cone beam computed tomography in diagnosis of periapical pathosis - A systematic review
    Kumar, Kiran N.
    Merwade, Seema
    Prabakaran, Pavithra
    Priya, Laxmi C. H.
    Annapoorna, B. S.
    Guruprasad, C. N.
    SAUDI DENTAL JOURNAL, 2021, 33 (08) : 784 - 794
  • [37] Evaluation of magnetic resonance imaging derived synthetic computed tomography for proton therapy planning in prostate cancer
    Fridstrom, Kajsa M. L.
    Winter, Rene M.
    Hornik, Natalie
    Almberg, Sigrun S.
    Danielsen, Signe
    Redalen, Kathrine R.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [38] DOSIMETRIC EFFECT OF INTRAFRACTION MOTION AND RESIDUAL SETUP ERROR FOR HYPOFRACTIONATED PROSTATE INTENSITY-MODULATED RADIOTHERAPY WITH ONLINE CONE BEAM COMPUTED TOMOGRAPHY IMAGE GUIDANCE
    Adamson, Justus
    Wu, Qiuwen
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (02): : 453 - 461
  • [39] Cone-beam computed tomography-guided online adaptive radiotherapy is feasible for prostate cancer patients
    Zwart, Lisanne G. M.
    Ong, Francisca
    Asbroek, Liselotte A. ten
    van Dieren, Erik B.
    Koch, Siete A.
    Bhawanie, Anand
    de Wit, Elisabeth
    Dasselaar, Judith J.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 98 - 103
  • [40] Cone beam computed tomography for imaging orbital trauma-image quality and radiation dose compared with conventional multislice computed tomography
    Brisco, Jessica
    Fuller, Karen
    Lee, Nicholas
    Andrew, David
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (01) : 76 - 80