Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis

被引:4
|
作者
Edmund, Jens M. [1 ,2 ]
Andreasen, Daniel [3 ]
Van Leemput, Koen [3 ,4 ]
机构
[1] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Oncol, Radiotherapy Res Unit, DK-2730 Herlev, Denmark
[2] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2021年 / 18卷
关键词
MRI-only RT; IGRT; Synthetic CT; Pseudo CT; Magnetic resonance imaging; Radiotherapy; Cone beam CT; SYNTHETIC CT GENERATION; RADIATION-THERAPY; NEURAL-NETWORK; MRI SEQUENCES; PSEUDO-CT;
D O I
10.1016/j.phro.2021.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Radiotherapy (RT) based on magentic resonance imaging (MRI) only is currently used clinically in the pelvis. A synthetic computed tomography (sCT) is needed for dose planning. Here, we investigate the accuracy of cone beam CT (CBCT) based MRI-only image guided RT (IGRT) and sCT image quality. Materials and methods: CT, MRI and CBCT scans of ten prostate cancer patients were included. The MRI was converted to a sCT using a multi-atlas approach. The sCT, CT and MR images were auto-matched with the CBCT on the bony anatomy. Paired sCT-CT and sCT-CBCT data were created. CT numbers were converted to relative electron (RED) and mass densities (DES) using a standard calibration curve for the CT and sCT. For the CBCT RED/DES conversion, a phantom and paired CT-CBCT population based calibration curve was used. For the latter, the CBCT numbers were averaged in 100 HU bins and the known RED/DES of the CT were assigned. The paired sCT-CT and sCT-CBCT data were averaged in bins of 10 HU or 0.01 RED/DES. The median absolute error (MeAE) between the sCT-CT and sCT-CBCT bins was calculated. Wilcoxon rank-sum tests were carried out for the IGRT and MeAE study. Results: The mean sCT or MR IGRT difference from CT was <= 2 mm but significant differences were observed. A CBCT HU or phantom-based RED/DES MeAE did not estimate the sCT quality similar to a CT based MeAE but the CBCT population-based RED/DES MeAE did. Conclusions: MRI-only CBCT-based IGRT seems feasible but caution is advised. A MeAE around 0.1 DES could call for sCT quality inspection.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [21] Dosimetric Comparison of Image Guidance by Megavoltage Computed Tomography versus Bone Alignment for Prostate Cancer Radiotherapy
    Kalz, Joern
    Sterzing, Florian
    Schubert, Kai
    Sroka-Perez, Gabriele
    Debus, Juergen
    Herfarth, Klaus
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (04) : 241 - 247
  • [22] Dosimetric Comparison of Image Guidance by Megavoltage Computed Tomography versus Bone Alignment for Prostate Cancer Radiotherapy
    Kalz, Joern
    Sterzing, Florian
    Schubert, Kai
    Sroka-Perez, Gabriele
    Debus, Juergen
    Herfarth, Klaus
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (04) : 241 - 247
  • [23] Magnetic Resonance Imaging only Workflow for Radiotherapy Simulation and Planning in Prostate Cancer
    Kerkmeijer, L. G. W.
    Maspero, M.
    Meijer, G. J.
    van Zyp, J. R. N. van der Voort
    de Boer, C. J.
    van den Berg, C. A. T.
    CLINICAL ONCOLOGY, 2018, 30 (11) : 692 - 701
  • [24] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [25] Computed Tomography/Magnetic Resonance Imaging (CT/MRI) Image Registration and Fusion Assessment for Accurate Glioblastoma Radiotherapy Treatment Planning
    Touabti, Khalil Mohamed Mokhtar
    Kharfi, Faycal
    Benkahila, Karim
    Merouane, Sid-Ali
    INTERNATIONAL JOURNAL OF CANCER MANAGEMENT, 2020, 13 (09) : 1 - 8
  • [26] Cone-beam computed tomography (CBCT) dose optimization technique and image quality assessment scoring
    Trivedi, Gaurav
    Singh, Pushpendra P.
    Oinam, Arun S.
    Singh, Ranjit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (01) : 71 - 78
  • [27] Intrafractional motion in stereotactic body radiotherapy of spinal metastases utilizing cone beam computed tomography image guidance
    Svestad, Jorund Graadal
    Ramberg, Christina
    Skar, Birgitte
    Hellebust, Taran Paulsen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 12 : 1 - 6
  • [28] Personalized Assessment of kV Cone Beam Computed Tomography Doses in Image-guided Radiotherapy of Pediatric Cancer Patients
    Zhang, Yibao
    Yan, Yulong
    Nath, Ravinder
    Bao, Shanglian
    Deng, Jun
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05): : 1649 - 1654
  • [29] Imaging Aspects of Palatal Torus in Cone Beam Computed Tomography and Magnetic Resonance: Case Report
    El Achkar, Vivian Narana Ribeiro
    Lopes, Sergio Lucio Pereira De Castro
    Pinto, Antonione Santos Bezerra
    Do Prado, Renata Falchete
    Kaminagakura, Estela
    ACTA STOMATOLOGICA CROATICA, 2016, 50 (04) : 359 - 364
  • [30] Geometric impact and dose estimation of on-patient placement of a lightweight receiver coil in a clinical magnetic resonance imaging-only radiotherapy workflow for prostate cancer
    Scherman, Jonas
    af Wetterstedt, Sacha
    Persson, Emilia
    Olsson, Lars E.
    Gustafsson, Christian Jamtheim
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26