Incisional hernia: challenge of re-operations after mesh repair

被引:31
作者
Conze, Joachim [1 ]
Krones, Carsten J. [1 ]
Schumpelick, Volker [1 ]
Klinge, Uwe [1 ]
机构
[1] Rhein Westfal TH Aachen, Surg Dept, D-52074 Aachen, Germany
关键词
incisional hernia; surgical mesh; recurrence; overlap; adhesion; shrinkage;
D O I
10.1007/s00423-006-0065-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background and aims The widespread use of meshes for the repair of incisional hernia is currently followed by an increasing number of re-operations. The incidence of incisional hernia recurrence after mesh repair varies between 3 and 32%. The problem of mesh failure and options for another surgical intervention seem rather unattended. Methods We present our experience of 77 re-operations after previous mesh repair that were performed between 1995 and 2004 out of a total of 1,070 operations for incisional hernia. The retrospective analysis focused on recurrence in relation to location, material of the previous mesh repair and the surgical procedure to resolve the problem. Results The locations of the preceding meshes were epifascial as onlays (n=23), retromuscular as sublays (n=46), within the defect as inlays (n=6) or intraperitoneally (n=2). The direction of the incision was vertical medial (n=41) or horizontal crossing the linea semilunaris (n=36). Recurrences after median incisional hernia mesh repair mainly occurred at the cranial border of the mesh subxiphoidal. Except for two patients, all recurrences manifested at the margin of the enclosed mesh. Conclusions Re-operation after previous mesh repair is a surgical challenge. The type of revision procedure has to consider the position and material of the previous mesh. In our clinic recurrences, heavyweight polypropylene meshes were mostly treated with mesh exchange and lightweight polypropylene meshes could be treated by extension with a second mesh. In contrast to suture techniques, deficient mesh repairs are more evidently related to technical problems.
引用
收藏
页码:453 / 457
页数:5
相关论文
共 16 条
  • [1] Burger JWA, 2004, ANN SURG, V240, P578
  • [2] Burger JWA, 2004, ANN SURG, V240, P583
  • [3] Conze J, 2004, Hernia, V8, P255
  • [4] Technical consideration for subxiphoidal incisional hernia repair
    Conze J.
    Prescher A.
    Kisielinski K.
    Klinge U.
    Schumpelick V.
    [J]. Hernia, 2005, 9 (1) : 84 - 87
  • [5] Have outcomes of incisional hernia repair improved with time? A population-based analysis
    Flum, DR
    Horvath, K
    Koepsell, T
    [J]. ANNALS OF SURGERY, 2003, 237 (01) : 129 - 135
  • [6] Höer J, 2002, CHIRURG, V73, P474, DOI 10.1007/s00104-002-0425-5
  • [7] The biology of hernia formation
    Jansen, PL
    Mertens, PR
    Klinge, U
    Schumpelick, V
    [J]. SURGERY, 2004, 136 (01) : 1 - 4
  • [8] Decreased collagen type I/III ratio in patients with recurring hernia after implantation of alloplastic prostheses
    Junge, K
    Klinge, U
    Rosch, R
    Mertens, PR
    Kirch, J
    Klosterhalfen, B
    Lynen, P
    Schumpelick, V
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2004, 389 (01) : 17 - 22
  • [9] Influence of implantation interval on the long-term biocompatibility of surgical mesh
    Klosterhalfen, B
    Junge, K
    Hermanns, B
    Klinge, U
    [J]. BRITISH JOURNAL OF SURGERY, 2002, 89 (08) : 1043 - 1048
  • [10] Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair
    Klosterhalfen, B
    Klinge, U
    Schumpelick, V
    [J]. BIOMATERIALS, 1998, 19 (24) : 2235 - 2246