Experimental analysis of R744 parallel compression cycle

被引:70
|
作者
Chesi, Andrea [1 ]
Esposito, Fabio [1 ]
Ferrara, Giovanni [1 ]
Ferrari, Lorenzo [2 ]
机构
[1] Univ Florence, Dept Ind Engn, I-50139 Florence, Italy
[2] Natl Council Res Italy, CNR ICCOM, I-50019 Sesto Fiorentino, FI, Italy
关键词
Experimentation; R744; Parallel compression; Flash tank; Separation effectiveness; CARBON-DIOXIDE; CO2; CYCLE; OPTIMIZATION; PERFORMANCE;
D O I
10.1016/j.apenergy.2014.08.087
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A diffuse interest on cycle modifications for R744 applications that allow to achieve better CO2 cycles performance can be inferred from the literature. The parallel compression cycle in flash tank configuration seems to be an interesting solution and the authors conducted an experimental campaign to estimate the critical parameters that influence its performance in an actual cycle. Previous to that a thermodynamic analysis was lead to investigate the expectable performance of the cycle and the influence of key parameters such as compressors volumetric flow ratio and separator efficiency. The thermodynamic model designed also allowed the definition of the limit conditions for an optimal operability of the cycle of interest. The experiments showed that the theoretically reachable improvements in terms of refrigerating capacity and coefficient of performance are threatened by several phenomena which may occur in a real system. These detrimental effects are described and commented in the paper. The paper also includes experimental data obtained during the experimental activity for operating conditions typical of commercial refrigeration applications. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:274 / 285
页数:12
相关论文
共 50 条
  • [1] Advanced exergy analysis of a R744 booster refrigeration system with parallel compression
    Gullo, Paride
    Elmegaard, Brian
    Cortella, Giovanni
    ENERGY, 2016, 107 : 562 - 571
  • [2] Performance study on a vapour compression refrigeration cycle using R744/R290, R744/R600 or R744/R600a as refrigerant
    Zhang, Xianping
    Qin, Guimian
    Wang, Fengkun
    Fan, Xiaowei
    Shen, Henggen
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1609 - 1615
  • [3] R744 EJECTOR SUPPORTED PARALLEL VAPOUR COMPRESSION SYSTEM
    Hafner, A.
    Schoenenberger, J.
    Banasiak, K.
    Girotto, S.
    3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 134 - 141
  • [4] INTEGRATED R744 EJECTOR SUPPORTED PARALLEL COMPRESSION RACKS FOR SUPERMARKETS. EXPERIMENTAL RESULTS
    Pardinas, Angel A.
    Hafner, Armin
    Banasiak, Krzysztof
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 1173 - 1180
  • [5] Experimental and computational analysis of a R744 flashing ejector
    Giacomelli, Francesco
    Mazzelli, Federico
    Banasiak, Krzysztof
    Hafner, Armin
    Milazzo, Adriano
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 107 : 326 - 343
  • [6] Experimental Analysis and Optimization of an R744 Transcritical Cycle Working with a Mechanical Subcooling System
    Sanchez, Daniel
    Catalan-Gil, Jesus
    Cabello, Ramon
    Calleja-Anta, Daniel
    Llopis, Rodrigo
    Nebot-Andres, Laura
    ENERGIES, 2020, 13 (12)
  • [7] Experimental evaluation of a cascade refrigeration system with the natural refrigerants R290/R744, R1270/R744 and R600a/R744
    Cabello, R.
    Sanchez, D.
    Andreu-Nacher, A.
    Llopis, R.
    Nebot-Andres, L.
    Calleja-Anta, D.
    Vidan-Falomir, F.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 616 - 626
  • [8] Experimental study of the refrigeration cycle performance for the R744/R290 mixtures
    Niu, Baolian
    Zhang, Yufeng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01): : 37 - 42
  • [9] INFLUENCE FACTORS IN PERFORMANCE OF THE TWO-STAGE COMPRESSION TRANSCRITICAL R744 CYCLE
    Almeida, I. M. G.
    Barbosa, C. R. F.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 782 - +
  • [10] Analysis of an R744 typical booster configuration, an R744 parallel-compressor booster configuration and an R717/R744 cascade refrigeration system for retail food applications. Part 1: Thermodynamic analysis
    Amaris, Carlos
    Tsamos, Konstantinos M.
    Tassou, Savvas A.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS INCLUDING WORKSHOP ON ENERGY RECOVERY CONVERSION AND MANAGEMENT;ICSEF 2018, 2019, 161 : 259 - 267