Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data

被引:125
作者
Kallemeyn, Nicole [1 ,3 ]
Gandhi, Anup [1 ,3 ]
Kode, Swathi [1 ,3 ]
Shivanna, Kiran [3 ]
Smucker, Joseph [2 ]
Grosland, Nicole [1 ,2 ,3 ]
机构
[1] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[2] Univ Iowa Hosp & Clin, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
[3] Univ Iowa, Ctr Comp Aided Design, Iowa City, IA 52242 USA
关键词
Finite element analysis; Cervical spine; Patient-specific modeling; LUMBAR SPINE; MECHANICAL-PROPERTIES; SEGMENT; DISC; BIOMECHANICS; CORRIDORS; LIGAMENTS; ROTATION; FACETS; STABILITY;
D O I
10.1016/j.medengphy.2010.03.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continuous moments up to +/- 1.0 N m in flexion, extension, lateral bending, and axial rotation, and the motions at each level were obtained. Additionally, the specimen was divided into C2-C3, C4-C5, and C6-C7 functional spinal units (FSUs) which were tested in the intact state as well as after sequential removal of the interspinous, ligamentum flavum, and capsular ligaments. The finite element model was initially assigned baseline material properties based on the literature, but was calibrated using the experimental motion data which was obtained in-house, while utlizing the ranges of material property values as reported in the literature. The calibrated model provided good agreement with the nonlinear experimental loading curves, and can be used to further study the response of the cervical spine to various biomechanical investigations. (C) 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:482 / 489
页数:8
相关论文
共 45 条
[1]  
BASA S, 2006, INT C BIOM PHARM ENG
[2]   Biomechanics of the cervical spine. I: Normal kinematics [J].
Bogduk, N ;
Mercer, S .
CLINICAL BIOMECHANICS, 2000, 15 (09) :633-648
[3]  
Bowden A.E., 2006, Spine Technology Handbook
[4]   Quality of motion considerations in numerical analysis of motion restoring implants of the spine [J].
Bowden, Anton E. ;
Guerin, Heather L. ;
Villarraga, Marta L. ;
Patwardhan, Avinash G. ;
Ochoa, Jorge A. .
CLINICAL BIOMECHANICS, 2008, 23 (05) :536-544
[5]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[6]   BIOMECHANICAL PROPERTIES OF SPINAL LIGAMENTS AND A HISTOLOGICAL STUDY OF THE SUPRASPINAL LIGAMENT IN TRACTION [J].
CHAZAL, J ;
TANGUY, A ;
BOURGES, M ;
GAUREL, G ;
ESCANDE, G ;
GUILLOT, M ;
VANNEUVILLE, G .
JOURNAL OF BIOMECHANICS, 1985, 18 (03) :167-176
[7]   Biomechanical comparison between lumbar disc arthroplasty and fusion [J].
Chen, Shih-Hao ;
Zhong, Zheng-Cheng ;
Chen, Chen-Sheng ;
Chen, Wen-Jer ;
Hung, Chinghua .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (02) :244-253
[8]  
Clausen J., 1996, EXPT THEORETICAL INV
[9]   Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5-C6 segment [J].
Clausen, JD ;
Goel, VK ;
Traynelis, VC ;
Scifert, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) :342-347
[10]   An accurate finite element model of the cervical spine under quasi-static loading [J].
del Palomar, A. Perez ;
Calvo, B. ;
Doblare, M. .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :523-531