Characteristics and outcomes of patients undergoing paraesophageal hernia repair with selective use of biologic mesh

被引:8
|
作者
Inaba, Colette S. [1 ]
Oelschlager, Brant K. [1 ]
Yates, Robert B. [1 ]
Khandelwal, Saurabh [1 ]
Chen, Judy Y. [1 ]
Wright, Andrew S. [1 ]
机构
[1] Univ Washington, Dept Surg, 1959 NE Pacific St,POB 356410, Seattle, WA 98195 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2022年 / 36卷 / 02期
关键词
Paraesophageal hernia; Hiatal hernia; Mesh; Recurrence; Reoperation; CRURAL RELAXING INCISIONS; LAPAROSCOPIC REPAIR; RECURRENCE; REINFORCEMENT; MULTICENTER; PROSTHESIS;
D O I
10.1007/s00464-021-08399-w
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The use of biologic mesh in paraesophageal hernia repair (PEHR) has been associated with decreased short-term recurrence but no statistically significant difference in long-term recurrence. Because of this, we transitioned from routine to selective use of mesh for PEHR. The aim of this study was to examine our indications for selective mesh use and to evaluate patient outcomes in this population. Methods We queried a prospectively maintained database for patients who underwent laparoscopic PEHR with biologic mesh from October 2015 to October 2018, then performed a retrospective chart review. The decision to use mesh was made intraoperatively by the surgeon. Recurrence was defined as the presence of > 2 cm intrathoracic stomach on postoperative upper gastrointestinal (UGI) series. Results Mesh was used in 61/169 (36%) of first-time PEHRs, and in 47/82 (57%) of redo PEHRs. Among first-time PEHRs, the indications for mesh included hiatal tension (85%), poor crural tissue quality (11%), or both (5%). Radiographic recurrence occurred in 15% of first-time patients (symptomatic N = 2, asymptomatic N = 3). There were no reoperations for recurrence. Among redo PEHRs, the indication for mesh was most commonly the redo nature of the repair itself (55%), but also hiatal tension (51%), poor crural tissue quality (13%), or both (4%). Radiographic recurrence occurred in 21% of patients (symptomatic N = 4, asymptomatic N = 1). There was 1 reoperation for recurrence in the redo-repair group. Conclusions We selectively use biologic mesh in a third of our first-time repair patients and in over half of our redo-repair patients when there is a perceived high risk of recurrence based on hiatal tension, poor tissue quality, or prior recurrence. Despite the high risk for radiologic recurrence, there was only 1 reoperation for recurrence in the entire cohort.
引用
收藏
页码:1627 / 1632
页数:6
相关论文
共 50 条
  • [31] Use of Mesh in Laparoscopic Paraesophageal Hernia Repair: A Meta-Analysis and Risk-Benefit Analysis
    Mueller-Stich, Beat P.
    Kenngott, Hannes G.
    Gondan, Matthias
    Stock, Christian
    Linke, Georg R.
    Fritz, Franziska
    Nickel, Felix
    Diener, Markus K.
    Gutt, Carsten N.
    Wente, Moritz
    Buechler, Markus W.
    Fischer, Lars
    PLOS ONE, 2015, 10 (10):
  • [32] PROsthetic MEsh Reinforcement in elective minimally invasive paraesophageal hernia repair (PROMER): an international survey
    Aiolfi, Alberto
    Bona, Davide
    Sozzi, Andrea
    Bonavina, Luigi
    UPDATES IN SURGERY, 2024, 76 (07) : 2675 - 2682
  • [33] Combination of Surgical Technique and Bioresorbable Mesh Reinforcement of the Crural Repair Leads to Low Early Hernia Recurrence Rates with Laparoscopic Paraesophageal Hernia Repair
    Abdelmoaty, Walaa F.
    Dunst, Christy M.
    Filicori, Filippo
    Zihni, Ahmed M.
    Davila-Bradley, Daniel
    Reavis, Kevin M.
    Swanstrom, Lee L.
    DeMeester, Steven R.
    JOURNAL OF GASTROINTESTINAL SURGERY, 2020, 24 (07) : 1477 - 1481
  • [34] Use of Polypropylene Strips for Reinforcement of the Cruroplasty in Laparoscopic Paraesophageal Hernia Repair: A Retrospective Cohort Study
    Van den Dop, L. Matthijs
    De Smet, Gijs H. J.
    Mamound, Aziz
    Lange, Johan
    Wijnhoven, Bas P. L.
    Hueting, Willem
    DIGESTIVE SURGERY, 2021, 38 (04) : 290 - 299
  • [35] Five-Year Outcomes from a Prospective Study on Safety and Efficacy of Phasix ST Mesh Use at the Hiatus During Paraesophageal Hernia Repair
    Mckay, Sarah C.
    Dunst, Christy M.
    Davila-Bradley, Daniel
    Reavis, Kevin M.
    Demeester, Steven R.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2024, 239 (04) : 333 - 338
  • [36] Revisional paraesophageal hernia repair outcomes compare favorably to initial operations
    John Wennergren
    Salomon Levy
    Curtis Bower
    Michael Miller
    Daniel Borman
    Daniel Davenport
    Margaret Plymale
    J. Scott Roth
    Surgical Endoscopy, 2016, 30 : 3854 - 3860
  • [37] Functional results after repair of large hiatal hernia by Use of a Biologic Mesh
    Antonakis, Filimon
    Koeckerling, Ferdinand
    Kallinowski, Friedrich
    FRONTIERS IN SURGERY, 2016, 3
  • [38] One More Time: Redo Paraesophageal Hernia Repair Results in Safe, Durable Outcomes Compared with Primary Repairs
    Kao, Angela M.
    Otero, Javier
    Schlosser, Kathryn A.
    Marx, Julia E.
    Prasad, Tanushree
    Colavita, Paul D.
    Heniford, B. Todd
    AMERICAN SURGEON, 2018, 84 (07) : 1138 - 1145
  • [39] The use of synthetic mesh in patients undergoing ventral hernia repair during colorectal resection: Risk of infection and recurrence
    El-Gazzaz, Galal H.
    Farag, Sherif H.
    El-Sayd, Mohamed A.
    Mohamed, Hatem H.
    ASIAN JOURNAL OF SURGERY, 2012, 35 (04) : 149 - 153
  • [40] A 13-year experience with biologic and biosynthetic absorbable mesh reinforced laparoscopic paraesophageal hernia repair
    Julia R. Amundson
    Kristine Kuchta
    Hoover Wu
    Vanessa N. VanDruff
    Stephen P. Haggerty
    John Linn
    Michael B. Ujiki
    Surgical Endoscopy, 2023, 37 : 7271 - 7279