Characteristics and outcomes of patients undergoing paraesophageal hernia repair with selective use of biologic mesh

被引:8
|
作者
Inaba, Colette S. [1 ]
Oelschlager, Brant K. [1 ]
Yates, Robert B. [1 ]
Khandelwal, Saurabh [1 ]
Chen, Judy Y. [1 ]
Wright, Andrew S. [1 ]
机构
[1] Univ Washington, Dept Surg, 1959 NE Pacific St,POB 356410, Seattle, WA 98195 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2022年 / 36卷 / 02期
关键词
Paraesophageal hernia; Hiatal hernia; Mesh; Recurrence; Reoperation; CRURAL RELAXING INCISIONS; LAPAROSCOPIC REPAIR; RECURRENCE; REINFORCEMENT; MULTICENTER; PROSTHESIS;
D O I
10.1007/s00464-021-08399-w
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The use of biologic mesh in paraesophageal hernia repair (PEHR) has been associated with decreased short-term recurrence but no statistically significant difference in long-term recurrence. Because of this, we transitioned from routine to selective use of mesh for PEHR. The aim of this study was to examine our indications for selective mesh use and to evaluate patient outcomes in this population. Methods We queried a prospectively maintained database for patients who underwent laparoscopic PEHR with biologic mesh from October 2015 to October 2018, then performed a retrospective chart review. The decision to use mesh was made intraoperatively by the surgeon. Recurrence was defined as the presence of > 2 cm intrathoracic stomach on postoperative upper gastrointestinal (UGI) series. Results Mesh was used in 61/169 (36%) of first-time PEHRs, and in 47/82 (57%) of redo PEHRs. Among first-time PEHRs, the indications for mesh included hiatal tension (85%), poor crural tissue quality (11%), or both (5%). Radiographic recurrence occurred in 15% of first-time patients (symptomatic N = 2, asymptomatic N = 3). There were no reoperations for recurrence. Among redo PEHRs, the indication for mesh was most commonly the redo nature of the repair itself (55%), but also hiatal tension (51%), poor crural tissue quality (13%), or both (4%). Radiographic recurrence occurred in 21% of patients (symptomatic N = 4, asymptomatic N = 1). There was 1 reoperation for recurrence in the redo-repair group. Conclusions We selectively use biologic mesh in a third of our first-time repair patients and in over half of our redo-repair patients when there is a perceived high risk of recurrence based on hiatal tension, poor tissue quality, or prior recurrence. Despite the high risk for radiologic recurrence, there was only 1 reoperation for recurrence in the entire cohort.
引用
收藏
页码:1627 / 1632
页数:6
相关论文
共 50 条
  • [21] The Choice of Primary Repair or Mesh Repair for Paraesophageal Hernia A Decision Analysis Based on Utility Scores
    Obeid, Nadia M.
    Velanovich, Vic
    ANNALS OF SURGERY, 2013, 257 (04) : 655 - 664
  • [22] Risk factors for adverse outcomes following paraesophageal hernia repair among obese patients
    Kanagasegar, Nithya
    Alvarado, Christine E.
    Lyons, Joshua L.
    Rivero, Marco-Jose
    Vekstein, Carolyn
    Levine, Iris
    Towe, Christopher W.
    Worrell, Stephanie G.
    Marks, Jeffrey M.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (09): : 6791 - 6797
  • [23] LAPAROSCOPIC PARAESOPHAGEAL HERNIA REPAIR WITH MESH
    EDELMAN, DS
    SURGICAL LAPAROSCOPY & ENDOSCOPY, 1995, 5 (01) : 32 - 37
  • [24] Laparoscopic Paraesophageal Hernia Repair: Utilization Rates of Mesh in the USA and Short-Term Outcome Analysis
    Schlottmann, Francisco
    Strassle, Paula D.
    Patti, Marco G.
    JOURNAL OF GASTROINTESTINAL SURGERY, 2017, 21 (10) : 1571 - 1576
  • [25] Revisional paraesophageal hernia repair outcomes compare favorably to initial operations
    Wennergren, John
    Levy, Salomon
    Bower, Curtis
    Miller, Michael
    Borman, Daniel
    Davenport, Daniel
    Plymale, Margaret
    Roth, J. Scott
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (09): : 3854 - 3860
  • [26] The safety of biologic mesh for laparoscopic repair of large, complicated hiatal hernia
    Wassenaar, Eelco B.
    Mier, Fernando
    Sinan, Huseyin
    Petersen, Rebecca P.
    Martin, A. Valeria
    Pellegrini, Carlos A.
    Oelschlager, Brant K.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (05): : 1390 - 1396
  • [27] Use of biologic mesh for a complicated paracolostomy hernia
    Lo Menzo, Emanuele
    Martinez, Jose M.
    Spector, Seth A.
    Iglesias, Alberto
    DeGennaro, Vincent
    Cappellani, Alesssandro
    AMERICAN JOURNAL OF SURGERY, 2008, 196 (05) : 715 - 719
  • [28] Impact of Operative Times and Mesh Utilization on Paraesophageal Hernia Repair: Analysis of 30-Day Outcomes from the American College of Surgeons National Surgical Quality Improvement Project Database
    Skancke, Matthew
    Brody, Fred
    Haskins, Ivy N.
    Amdur, Richard
    Schoolfield, Clint
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2019, 29 (03): : 303 - 308
  • [29] Optimizing outcomes in paraesophageal hernia repair: a novel critical view
    Saleh, Zena
    Verchio, Vincent
    Ghanem, Yazid K.
    Lou, Johanna
    Hundley, Erin
    Rouhi, Armaun D.
    Joshi, Hansa
    Moccia, Mathew C.
    Scalia, Dominick M.
    Lenart, Austin M.
    Ladd, Zachary A.
    Minakata, Kenji
    Shersher, David D.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2024, 38 (09): : 5385 - 5393
  • [30] PROsthetic MEsh Reinforcement in elective minimally invasive paraesophageal hernia repair (PROMER): an international survey
    Alberto Aiolfi
    Davide Bona
    Andrea Sozzi
    Luigi Bonavina
    Updates in Surgery, 2024, 76 (7) : 2675 - 2682