Flame spread over horizontal and vertical wires: The role of dripping and core

被引:80
|
作者
Kobayashi, Yoshinari [1 ]
Huang, Xinyan [2 ]
Nakaya, Shinji [1 ]
Tsue, Mitsuhiro [1 ]
Fernandez-Pello, Carlos [2 ]
机构
[1] Univ Tokyo, Dept Aeronaut & Astronaut, 7-3-1 Hongo, Tokyo 1138656, Japan
[2] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
关键词
Polyethylene (PE); Dripping fraction; Burning rate; Core temperature profile; ELECTRIC WIRE; POLYMERIC COATINGS; GLASS THREADS; COPPER WIRES; FIRE; MECHANISMS; INSULATION;
D O I
10.1016/j.firesaf.2017.03.047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dripping of polymer insulations in wire fire has a potential risk of igniting nearby objects and expanding the size of fire, but has not been well studied so far. In this experimental study, dripping behaviors during the flame spread over horizontal and vertical polyethylene (PE) insulated wires were investigated without external airflow. Two different wire dimensions - core/wire diameter of 3.5/8.0 and 5.5/9.0 mm and three different PE insulations were tested. To identify effects of the core, wires with solid copper (Cu) core, hollow stainless steel (SS) core, and without core were tested, and both core and insulation temperatures were also measured during the flame spread. Experimental results showed that the high-conductance copper core acted as a heat source downstream to increase the flame-spread rate. However, in the upstream burning zone, the copper core also acted as a heat sink to cool the molten insulation and reduce its mobility. Thus, the copper core extended the residence time of molten insulation inside the flame to facilitate the burning while reducing the dripping. Moreover, for the downward flame spread, the heating by the dripping flow of hot molten insulation dominated over the heating by the core. The downward dripping flow is driven by gravity while limited by the viscous and surface tension forces. Therefore, the limited dripping flow along the cooler copper core reduced the downward flame spread. The trend of results was also found to be insensitive to the type of PE insulation. This is the first time that within a single flame, the simultaneous dual effect of the heat source and heat sink for the wire core was observed, and the influence of dripping on the flame spread over the wire was discovered.
引用
收藏
页码:112 / 122
页数:11
相关论文
共 50 条
  • [1] Concurrent Flame Spread and Blow-Off Over Horizontal Thin Electrical Wires
    Lu, Yong
    Hu, Longhua
    Huang, Xinyan
    Fernandez-Pello, Carlos
    FIRE TECHNOLOGY, 2019, 55 (01) : 193 - 209
  • [2] Effect of insulation melting and dripping on opposed flame spread over laboratory simulated electrical wires
    Kobayashi, Yoshinari
    Konno, Yusuke
    Huang, Xinyan
    Nakaya, Shinji
    Tsue, Mitsuhiro
    Hashimoto, Nozomu
    Fujita, Osamu
    Fernandez-Pello, Carlos
    FIRE SAFETY JOURNAL, 2018, 95 : 1 - 10
  • [3] Role of wire core in extinction of opposed flame spread over thin electric wires
    Konno, Yusuke
    Hashimoto, Nozomu
    Fujita, Osamu
    COMBUSTION AND FLAME, 2020, 220 : 7 - 15
  • [4] Modelling of opposed flame spread over thin electric wires: estimation of flame spread rates and limiting oxygen concentrations
    Konno, Yusuke
    Hashimoto, Nozomu
    Fujita, Osamu
    COMBUSTION THEORY AND MODELLING, 2024, 28 (04) : 459 - 490
  • [5] Effect of copper core diameter on heat transfer and horizontal flame spread behaviors over electrical wire
    Huang, Xinjie
    Zhou, Zhijie
    Gao, Jinda
    Hu, Junjie
    Wang, Changlong
    Zhang, Xiaofeng
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [6] Fire safety in space - Investigating flame spread interaction over wires
    Citerne, Jean-Marie
    Dutilleul, Hugo
    Kizawa, Koki
    Nagachi, Masashi
    Fujita, Osamu
    Kikuchi, Masao
    Jomaas, Grunde
    Rouvreau, Sebastien
    Torero, Jose L.
    Legros, Guillaume
    ACTA ASTRONAUTICA, 2016, 126 : 500 - 509
  • [7] Flame spread over twin electrical wires with applied DC electric fields
    Park, Sun Ho
    Kang, Min Seong
    Cha, Min Suk
    Park, Jeong
    Chung, Suk Ho
    COMBUSTION AND FLAME, 2019, 210 : 350 - 359
  • [8] Effect of reduced ambient pressures and opposed airflows on the flame spread and dripping of LDPE insulated copper wires
    Gagnon, Lauren
    Fernandez-Pello, Carlos
    Urban, James L.
    Carey, Van P.
    Konno, Yusuke
    Fujita, Osamu
    FIRE SAFETY JOURNAL, 2021, 120
  • [9] Effects of confined distance and wire spacing on flame spread over double electrical wires for the layout design in buildings
    Huang, Xinjie
    Zhang, Meng
    Ding, Hailong
    Xu, Peng
    Zhang, Xinyi
    Li, Xinyi
    Wang, Miaomiao
    Zhang, Pengyuan
    JOURNAL OF BUILDING ENGINEERING, 2024, 92
  • [10] Flame spread over inclined wires: The effect of molten flow behavior
    Liang, Yuntao
    Li, Shihao
    Chen, Yue
    Liu, Zhiyang
    Tian, Fuchao
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 58