Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: A comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges

被引:71
作者
Duszak, R
Haskal, ZJ
Thomas-Hawkins, C
Soulen, MC
Baum, RA
Shlansky-Goldberg, RD
Cope, C
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Hosp Univ Penn, Dept Med Nursing, Philadelphia, PA 19104 USA
关键词
catheters and catheterization; complications; dialysis;
D O I
10.1016/S1051-0443(98)70275-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Tunneled hemodialysis catheter dysfunction often occurs from fibrin sheath formation, As a way to preserve existing catheter venous access sites, the authors evaluated over-the-wire exchange of catheters through pre-existing subcutaneous tunnels as an alternative to catheter removal and de novo catheter replacement. PATIENTS AND METHODS: One hundred nineteen catheters were placed in 68 patients, Seventy-seven catheters were placed de novo and 42 catheters were placed through the pre-existing subcutaneous tunnels of failing catheters, Technical success, short-term complications, infection rates, and functional catheter longevity were evaluated. RESULTS: Technical success for catheter exchange was 93%, Infection rates were comparable to those of de novo catheter placement: 0.15 and 0.11 infections per 100 catheter days for de novo and exchanged catheters, respectively, Catheter duration of function was not significantly different for de novo versus exchanged catheters: 63% and 51% at 3 months, 51% and 37% at 6 months, and 35% and 30% at 12 months, respectively. CONCLUSIONS: Over-the-wire exchange of tunneled hemodialysis catheters is safe and easily performed, It causes no increase in infectious complications and provides similar catheter longevity to de novo catheter placement, The procedure is an important option for prolonging tunneled hemodialysis catheter access sites.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 25 条
  • [1] SEPTICEMIA IN LONG-TERM JUGULAR HEMODIALYSIS CATHETERS - ERADICATING INFECTION BY CHANGING THE CATHETER OVER A GUIDEWIRE
    CARLISLE, EJF
    BLAKE, P
    MCCARTHY, F
    VAS, S
    ULDALL, R
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (03) : 150 - 153
  • [2] SUPERIORITY OF THE INTERNAL JUGULAR OVER THE SUBCLAVIAN ACCESS FOR TEMPORARY DIALYSIS
    CIMOCHOWSKI, GE
    WORLEY, E
    RUTHERFORD, WE
    SARTAIN, J
    BLONDIN, J
    HARTER, H
    [J]. NEPHRON, 1990, 54 (02): : 154 - 161
  • [3] Fibrin sleeve stripping for salvage of failing hemodialysis catheters: Technique and initial results
    Crain, MR
    Mewissen, MW
    Ostrowski, GJ
    PazFumagalli, R
    Beres, RA
    Wertz, RA
    [J]. RADIOLOGY, 1996, 198 (01) : 41 - 44
  • [4] CRAIN MR, 1994, J AM SOC NEPHROL, V5, P412
  • [5] DECICCO M, 1989, LANCET, V2, P1258, DOI 10.1016/S0140-6736(89)91861-8
  • [6] PLACEMENT AND MANAGEMENT OF LONG-TERM CENTRAL VENOUS ACCESS CATHETERS AND PORTS
    DENNY, DF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (02) : 385 - 393
  • [7] Replacement of accidentally removed tunneled venous catheters through existing subcutaneous tracts
    Egglin, TKP
    Rosenblatt, M
    Dickey, KW
    Houston, JP
    Pollak, JS
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (02) : 197 - 202
  • [8] THERAPY FOR THROMBOTIC OCCLUSION OF LONG-TERM INTRAVENOUS ALIMENTATION CATHETERS
    GLYNN, MFX
    LANGER, B
    JEEJEEBHOY, KN
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1980, 4 (04) : 387 - 390
  • [9] HAIRE WD, 1990, CANCER, V66, P2279, DOI 10.1002/1097-0142(19901201)66:11<2279::AID-CNCR2820661105>3.0.CO
  • [10] 2-O