Simultaneous fingerprint and high-wavenumber fiber-optic Raman spectroscopy enhances real-time in vivo diagnosis of adenomatous polyps during colonoscopy

被引:75
|
作者
Bergholt, Mads Sylvest [1 ]
Lin, Kan [1 ]
Wang, Jianfeng [1 ]
Zheng, Wei [1 ]
Xu, Hongzhi [2 ]
Huang, Qingwen [2 ]
Ren, Jian-lin [2 ]
Ho, Khek Yu [3 ,4 ]
Teh, Ming [5 ,6 ]
Srivastava, Supriya [5 ,6 ]
Wong, Benjamin [5 ,6 ]
Yeoh, Khay Guan [3 ,4 ]
Huang, Zhiwei [1 ]
机构
[1] Natl Univ Singapore, Fac Engn, Dept Biomed Engn, Opt Bioimaging Lab, 9 Engn Dr 1, Singapore 117576, Singapore
[2] Xiamen Univ, Zhongshan Hosp, Dept Gastroenterol, Inst Digest Dis, Xiamen 361004, Peoples R China
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Med, Singapore 119260, Singapore
[4] Natl Univ Hlth Syst, Singapore 119260, Singapore
[5] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Pathol, Singapore 119074, Singapore
[6] Natl Univ Hlth Syst, Singapore 119074, Singapore
基金
新加坡国家研究基金会; 英国医学研究理事会;
关键词
Raman spectroscopy; adenomatous polyp; colon; colonoscopy; in vivo optical diagnosis; OPTICAL DIAGNOSIS; CLASSIFICATION; TISSUE;
D O I
10.1002/jbio.201400141
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Colorectal cancer can be prevented if detected early (e.g., precancerous polyps-adenoma). Endoscopic differential diagnosis of hyperplastic polyps (that have little or no risk of malignant transformation) and adenomas (that have prominent malignant latency) remains an unambiguous clinical challenge. Raman spectroscopy is an optical vibrational technique capable of probing biomolecular changes of tissue associated with neoplastic transformation. This work aims to apply a fiber-optic simultaneous fingerprint (FP) and high wavenumber (HW) Raman spectroscopy technique for real-time in vivo assessment of adenomatous polyps during clinical colonoscopy. We have developed a fiber-optic Raman endoscopic technique capable of simultaneously acquiring both the FP (i.e., 800-1800 cm(-1)) and HW (i.e., 2800-3600 cm(-1)) Raman spectra from colorectal tissue subsurface (< 200 mu m) for real-time assessment of colorectal carcinogenesis. In vivo FP/HW Raman spectra were acquired from 50 patients with 17 colorectal polyps during clinical colonoscopy. Prominent Raman spectral differences (p < 0.001) were found between hyperplastic (n = 118 spectra), adenoma (n = 184 spectra) that could be attributed to changes in inter- and [GRAPHICS] intra-cellular proteins, lipids, DNA and water structures and conformations. Simultaneous FP/HW Raman endoscopy provides a diagnostic sensitivity of 90.9% and specificity of 83.3% for differentiating adenoma from hyperplastic polyps, which is superior to either the FP or HW Raman technique alone. This study shows that simultaneous FP/HW Raman spectroscopy technique has the potential to be a clinically powerful tool for improving early diagnosis of adenomatous polyps in vivo during colonoscopic examination.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 11 条
  • [1] Simultaneous fingerprint and high-wavenumber fiber-optic Raman endoscopy for in vivo diagnosis of laryngeal cancer
    Lin, Kan
    Zheng, Wei
    Wang, Jianfeng
    Lim, Chwee Ming
    Huang, Zhiwei
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [2] Simultaneous fingerprint and high-wavenumber fiber-optic Raman spectroscopy improves in vivo diagnosis of esophageal squamous cell carcinoma at endoscopy
    Wang, Jianfeng
    Lin, Kan
    Zheng, Wei
    Ho, Khek Yu
    Teh, Ming
    Yeoh, Khay Guan
    Huang, Zhiwei
    SCIENTIFIC REPORTS, 2015, 5
  • [3] Simultaneous fingerprint and high-wavenumber Raman endoscopy for in vivo diagnosis of colorectal precancer
    Lin, Kan
    Wang, Jianfeng
    Bergholt, Mads Sylvest
    Zheng, Wei
    Xu, Hongzhi
    Ren, Jian-lin
    Ho, Khek Yu
    Teh, Ming
    Yeoh, Khay Guan
    Huang, Zhiwei
    ENDOSCOPIC MICROSCOPY X; AND OPTICAL TECHNIQUES IN PULMONARY MEDICINE II, 2015, 9304
  • [4] Simultaneous Fingerprint and High-Wavenumber Confocal Raman Spectroscopy Enhances Early Detection of Cervical Precancer In Vivo
    Duraipandian, Shiyamala
    Zheng, Wei
    Ng, Joseph
    Low, Jeffrey J. H.
    Ilancheran, A.
    Huang, Zhiwei
    ANALYTICAL CHEMISTRY, 2012, 84 (14) : 5913 - 5919
  • [5] Real-time In vivo Diagnosis of Nasopharyngeal Carcinoma Using Rapid Fiber-Optic Raman Spectroscopy
    Lin, Kan
    Zheng, Wei
    Lim, Chwee Ming
    Huang, Zhiwei
    THERANOSTICS, 2017, 7 (14): : 3517 - 3526
  • [6] Real-time in vivo diagnosis of laryngeal carcinoma with rapid fiber-optic Raman spectroscopy
    Lin, Kan
    Zheng, Wei
    Lim, Chwee Ming
    Huang, Zhiwei
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (09): : 3705 - 3715
  • [7] Fiber-Optic Raman Spectroscopy with Nature-Inspired Genetic Algorithms Enhances Real-Time in Vivo Detection and Diagnosis of Nasopharyngeal Carcinoma
    Zuvela, Petar
    Liu, Kan
    Shu, Chi
    Zheng, Wei
    Lim, Chwee Ming
    Huang, Zhiwei
    ANALYTICAL CHEMISTRY, 2019, 91 (13) : 8101 - 8108
  • [8] Rapid Fiber-optic Raman Spectroscopy for Real-Time In Vivo Detection of Gastric Intestinal Metaplasia during Clinical Gastroscopy
    Lin, Kan
    Wang, Jianfeng
    Zheng, Wei
    Ho, Khek Yu
    Teh, Ming
    Yeoh, Khay Guan
    Huang, Zhiwei
    CANCER PREVENTION RESEARCH, 2016, 9 (06) : 476 - 483
  • [9] Development of a multiplexing fingerprint and high wavenumber Raman spectroscopy technique for real-time in vivo tissue Raman measurements at endoscopy
    Bergholt, Mads Sylvest
    Zheng, Wei
    Huang, Zhiwei
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (03)
  • [10] Real-time Raman spectroscopy for in vivo, online gastric cancer diagnosis during clinical endoscopic examination
    Duraipandian, Shiyamala
    Bergholt, Mads Sylvest
    Zheng, Wei
    Ho, Khek Yu
    Teh, Ming
    Yeoh, Khay Guan
    So, Jimmy Bok Yan
    Shabbir, Asim
    Huang, Zhiwei
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (08)