Dual-channel capillary electrophoresis for simultaneous determination of cations and anions

被引:30
|
作者
Opekar, Frantisek [1 ]
Tuma, Petr [2 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, Albertov 2030, Prague 12843 2, Czech Republic
[2] Charles Univ Prague, Fac Med 3, Inst Biochem Cell & Mol Biol, Ruska 87, Prague 10000 10, Czech Republic
关键词
Dual-channel electrophoresis; Short capillary separation; Inorganic ions; Mineral fertiliser; Piezoelectric micropump; CONTACTLESS CONDUCTIVITY DETECTION; INJECTION-ANALYSIS MANIFOLD; SIMULTANEOUS SEPARATION; CONCURRENT DETERMINATION; ZONE-ELECTROPHORESIS; INORGANIC ANIONS; DETECTOR; SAMPLES; SYSTEM;
D O I
10.1016/j.chroma.2016.04.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An original electrophoresis apparatus for simultaneous rapid determination of cations and anions has been designed and tested. The separation part of the apparatus consists of two identical fused-silica capillaries, each with a length of 10.5 cm and inner diameter of 25 mu m. The injection space is formed by the crossing of four channels in a plexiglass cross-piece. The capillaries pass through two opposing channels and their injection ends are located opposite one another at a distance of approx. 0.5 mm in the centre of the crossing point. The exit ends of the capillaries are placed in vessels containing the background electrolyte in which are immersed the electrodes of a high-voltage source. Contactless conductivity detectors with semi-cylindrical electrodes are located 2 cm from the exit ends of the capillaries. The injection part of the apparatus consists of two piezoelectric micro-pumps bringing the solution through another channel in the cross-piece to the injection ends of the capillary. During the injection, the sample is brought through one of them and is injected electrokinetically for a defined time. Then the sample zone is forced out of the injection space by a stream of background electrolyte from the second micro-pump. The timing of the injection process is computer-controlled. Thus the equipment can be considered to constitute electrophoresis in one capillary with injection into its centre. The use of short capillaries and miniature micro-pumps without other mechanical components enabled the construction of the apparatus on a board with dimensions of 20 x 25 cm. The proposed equipment was used to test simultaneous separation of a mixture of cations and anions, NH4+, K+, Ca2+, Mg2+, Sr2+, Ba2+, Cl-, NO3-, SO42-, ClO3- and F-, in BGE with composition 500mM HAc + 20 mM Tris + 2 mM 18-crown-6 (pH 3.3). Baseline separation of all the components was achieved in time less than 1 min. Quantification of the content of nitrate nitrogen (determined as NO3-), ammoniacal nitrogen (determined as NH4+),K2O (determined as K+) and SO3 (determined as SO42-) was performed on a real-world sample of mineral fertiliser. The determined compositions differed from the declared contents by an amount of 0.5-5.6%; the RSD value expressing the repeatability of the determination was in the range 3.4-7.5%. The LOD values were in the range from 6.9 mu M (K+) to 10.6 mu M (NH4+). (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 50 条
  • [21] Simultaneous determination of inorganic anions and cations in wine by capillary electrophoresis-indirect ultraviolet detection with ionic liquid as background electrolyte
    Tian Miaomiao
    Liu Xin
    Yang Li
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (03) : 356 - 361
  • [22] Simultaneous capillary electrophoresis of anions and cations in a single injection using an anion exchanger-modified capillary for determination of salivary ions in combination with statistical analyses
    Mori, Masanobu
    Aoyagi, Keisuke
    Tomoda, Toshihiro
    Ishikawara, Fumi
    Sakamoto, Shou
    Myochin, Hironori
    Kuga, Midori
    Kozaki, Daisuke
    Ohshima, Noriyasu
    Izumi, Takashi
    Itabashi, Hideyuki
    Shoho, Yoshifumi
    Yoshida, Akihiro
    Tsunekawa, Katsuhiko
    Kimura, Takao
    Murakami, Masami
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1635
  • [23] Enhanced aminophenols monitoring using in-channel amperometric detection with dual-channel microchip capillary electrophoresis
    Chen, Chuanpin
    Hahn, Jong Hoon
    ENVIRONMENTAL CHEMISTRY LETTERS, 2011, 9 (04) : 491 - 497
  • [25] Application of capillary electrophoresis to determine metal cations, anions, organic acids, and carbohydrates in some Pinot Noir red wines
    Rovio, Stella
    Siren, Kimmo
    Siren, Heli
    FOOD CHEMISTRY, 2011, 124 (03) : 1194 - 1200
  • [26] Application of Capillary Electrophoresis for Determination of Inorganic Analytes in Waters
    Pobozy, Ewa
    Trojanowicz, Marek
    MOLECULES, 2021, 26 (22):
  • [27] Simultaneous determination of inorganic anions, organic acids, amino acids and carbohydrates by capillary electrophoresis
    Soga, T
    Ross, GA
    JOURNAL OF CHROMATOGRAPHY A, 1999, 837 (1-2) : 231 - 239
  • [28] Screening determination of pharmaceutical pollutants in different water matrices using dual-channel capillary electrophoresis coupled with contactless conductivity detection
    Minh Duc Le
    Hong Anh Duong
    Manh Huy Nguyen
    Saiz, Jorge
    Hung Viet Pham
    Thanh Duc Mai
    TALANTA, 2016, 160 : 512 - 520
  • [29] Simultaneous Determination of Inorganic Cations and Anions in Microchip Electrophoresis Using High-voltage Relays
    Huang, Zhe
    Yang, Mingpeng
    You, Hui
    Xie, Yang
    ANALYTICAL SCIENCES, 2018, 34 (07) : 801 - 805
  • [30] Simultaneous separation and determination of four uncaria alkaloids by capillary electrophoresis using dual cyclodextrin system
    Li, Lou
    Xu, Liying
    Chen, Meng
    Zhang, Guangbin
    Zhang, Hongfen
    Chen, Anjia