Dual-channel capillary electrophoresis for simultaneous determination of cations and anions

被引:30
|
作者
Opekar, Frantisek [1 ]
Tuma, Petr [2 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, Albertov 2030, Prague 12843 2, Czech Republic
[2] Charles Univ Prague, Fac Med 3, Inst Biochem Cell & Mol Biol, Ruska 87, Prague 10000 10, Czech Republic
关键词
Dual-channel electrophoresis; Short capillary separation; Inorganic ions; Mineral fertiliser; Piezoelectric micropump; CONTACTLESS CONDUCTIVITY DETECTION; INJECTION-ANALYSIS MANIFOLD; SIMULTANEOUS SEPARATION; CONCURRENT DETERMINATION; ZONE-ELECTROPHORESIS; INORGANIC ANIONS; DETECTOR; SAMPLES; SYSTEM;
D O I
10.1016/j.chroma.2016.04.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An original electrophoresis apparatus for simultaneous rapid determination of cations and anions has been designed and tested. The separation part of the apparatus consists of two identical fused-silica capillaries, each with a length of 10.5 cm and inner diameter of 25 mu m. The injection space is formed by the crossing of four channels in a plexiglass cross-piece. The capillaries pass through two opposing channels and their injection ends are located opposite one another at a distance of approx. 0.5 mm in the centre of the crossing point. The exit ends of the capillaries are placed in vessels containing the background electrolyte in which are immersed the electrodes of a high-voltage source. Contactless conductivity detectors with semi-cylindrical electrodes are located 2 cm from the exit ends of the capillaries. The injection part of the apparatus consists of two piezoelectric micro-pumps bringing the solution through another channel in the cross-piece to the injection ends of the capillary. During the injection, the sample is brought through one of them and is injected electrokinetically for a defined time. Then the sample zone is forced out of the injection space by a stream of background electrolyte from the second micro-pump. The timing of the injection process is computer-controlled. Thus the equipment can be considered to constitute electrophoresis in one capillary with injection into its centre. The use of short capillaries and miniature micro-pumps without other mechanical components enabled the construction of the apparatus on a board with dimensions of 20 x 25 cm. The proposed equipment was used to test simultaneous separation of a mixture of cations and anions, NH4+, K+, Ca2+, Mg2+, Sr2+, Ba2+, Cl-, NO3-, SO42-, ClO3- and F-, in BGE with composition 500mM HAc + 20 mM Tris + 2 mM 18-crown-6 (pH 3.3). Baseline separation of all the components was achieved in time less than 1 min. Quantification of the content of nitrate nitrogen (determined as NO3-), ammoniacal nitrogen (determined as NH4+),K2O (determined as K+) and SO3 (determined as SO42-) was performed on a real-world sample of mineral fertiliser. The determined compositions differed from the declared contents by an amount of 0.5-5.6%; the RSD value expressing the repeatability of the determination was in the range 3.4-7.5%. The LOD values were in the range from 6.9 mu M (K+) to 10.6 mu M (NH4+). (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 50 条
  • [1] Simultaneous separation of cations and anions in capillary electrophoresis
    Saiz, Jorge
    Koenka, Israel Joel
    Thanh Duc Mai
    Hauser, Peter C.
    Garcia-Ruiz, Carmen
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 62 : 162 - 172
  • [2] Concurrent determination of anions and cations in consumer fireworks with a portable dual-capillary electrophoresis system
    Saiz, Jorge
    Duc, Mai Thanh
    Koenka, Israel Joel
    Martin-Alberca, Carlos
    Hauser, Peter C.
    Garcia-Ruiz, Carmen
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1372 : 245 - 252
  • [3] Thermostatted dual-channel portable capillary electrophoresis instrument
    Koenka, Israel Joel
    Kung, Nina
    Kuban, Pavel
    Chwalek, Thomas
    Furrer, Gerhard
    Wehrli, Bernhard
    Muller, Beat
    Hauser, Peter C.
    ELECTROPHORESIS, 2016, 37 (17-18) : 2368 - 2375
  • [4] Simultaneous determination of inorganic anions and cations in waters by capillary electrophoresis
    Padarauskas, A
    Olsauskaité, V
    Paliulionyté, V
    JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) : 359 - 365
  • [5] Simultaneous separation of cations and anions in capillary electrophoresis - recent applications
    Koenka, Israel Joel
    Mai, Thanh Duc
    Hauser, Peter C.
    Saiz, Jorge
    ANALYTICAL METHODS, 2016, 8 (07) : 1452 - 1456
  • [6] Polymeric Microchip for the Simultaneous Determination of Anions and Cations by Hydrodynamic Injection Using a Dual-Channel Sequential Injection Microchip Electrophoresis System
    Gaudry, Adam J.
    Nai, Yi Heng
    Guij, Rosanne M.
    Breadmore, Michael C.
    ANALYTICAL CHEMISTRY, 2014, 86 (07) : 3380 - 3388
  • [7] Automated dual capillary electrophoresis system with hydrodynamic injection for the concurrent determination of cations and anions
    Thi Thanh Thuy Pham
    Thanh Duc Mai
    Thanh Dam Nguyen
    Saiz, Jorge
    Hung Viet Pham
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2014, 841 : 77 - 83
  • [8] Simultaneous determination of inorganic anions and cations by capillary electrophoresis with indirect UV detection
    Haumann, I
    Boden, J
    Mainka, A
    Jegle, U
    JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) : 269 - 277
  • [9] Simultaneous determination of inorganic anions, organic acids and metal cations by capillary electrophoresis
    Tomoyoshi, S
    Ross, GA
    JOURNAL OF CHROMATOGRAPHY A, 1999, 834 (1-2) : 65 - 71
  • [10] Application of a contactless conductometric detector for the simultaneous determination of small anions and cations by capillary electrophoresis with dual-opposite end injection
    Kubán, P
    Karlberg, B
    Kubán, P
    Kubán, V
    JOURNAL OF CHROMATOGRAPHY A, 2002, 964 (1-2) : 227 - 241