Modelling the impact of multizone airleakage on ventilation performance and indoor air quality in low-energy homes

被引:8
|
作者
Guyot, Gaelle [1 ,2 ]
Geoffroy, Hugo [2 ]
Ondarts, Michel [2 ]
Migne, Lena [2 ]
Bobee, Mallory [2 ]
Gonze, Evelyne [2 ]
Woloszyn, Monika [2 ]
机构
[1] Cerema, Direct Ctr Est, 46 Rue St Theobald, F-38080 Lisle Dabeau, France
[2] Univ Grenoble Alpes, Univ Savoie Mt Blanc, CNRS, LOCIE, F-73000 Chambery, France
关键词
indoor air quality; ventilation; house; performance; airleakage; infiltration; formaldehyde; indicator; RATES; TRANSPORT; EXPOSURE; FRENCH; FLOW; FORMALDEHYDE; SIMULATION; POLLUTANTS; HUMIDITY;
D O I
10.1007/s12273-019-0557-x
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study examined the impacts of detailed envelope airleakage distribution and internal partition walls airleakage on the ventilation performance of a detached low-energy house. We used a multizone modelling approach based on CO2, humidity and formaldehyde to calculate indoor air quality (IAQ) performance indicators. Impacts of uneven envelope airleakage distribution on selected IAQ performance indicators are generally significant whatever ventilation system is present. Impacts of internal partition wall airleakage are considerably greater with exhaust-only ventilation but can be high on some IAQ performance indicators with balanced ventilation. We also conclude that it is relevant to use detailed data on envelope airleakage distribution and internal partition wall airleakage to precisely assess ventilation performance on IAQ. This work highlights the need of regulations or labels requiring performance-based approaches for ventilation at the design stage of buildings, calculating the relevant IAQ performance indicators. In such multizone modelling approaches, detailed airleakage distributions, on envelope and on internal partition walls, should be taken into account.
引用
收藏
页码:1141 / 1159
页数:19
相关论文
共 50 条
  • [1] Modelling the impact of multizone airleakage on ventilation performance and indoor air quality in low-energy homes
    Gaëlle Guyot
    Hugo Geoffroy
    Michel Ondarts
    Léna Migne
    Mallory Bobee
    Evelyne Gonze
    Monika Woloszyn
    Building Simulation, 2019, 12 : 1141 - 1159
  • [2] Multizone air leakage measurements and interactions with ventilation flows in low-energy homes
    Guyot, Gaelle
    Ferlay, Jeremy
    Gonze, Evelyne
    Woloszyn, Monika
    Planet, Pierre
    Bello, Thibaud
    BUILDING AND ENVIRONMENT, 2016, 107 : 52 - 63
  • [3] Indoor Air Quality Campaign in an Occupied Low-Energy House with a High Level of Spatial and Temporal Discretization
    Kanama, Najwa
    Ondarts, Michel
    Guyot, Gaelle
    Outin, Jonathan
    Gonze, Evelyne
    APPLIED SCIENCES-BASEL, 2021, 11 (24):
  • [4] Ventilation performance and indoor air pollutants diagnosis in 21 French low energy homes
    Guyot, Gaelle
    Melois, Adeline
    Bernard, Anne-Marie
    Coeudevez, Claire-Sophie
    Deoux, Suzanne
    Berlin, Sandra
    Parent, Enora
    Huet, Alexis
    Berthault, Sylvain
    Jobert, Romuald
    Labaume, Damien
    INTERNATIONAL JOURNAL OF VENTILATION, 2018, 17 (03) : 187 - 195
  • [5] Smart ventilation energy and indoor air quality performance in residential buildings: A review
    Guyot, Gaelle
    Sherman, Max H.
    Walker, Iain S.
    ENERGY AND BUILDINGS, 2018, 165 : 416 - 430
  • [6] Towards the definition of indicators for assessment of indoor air quality and energy performance in low-energy residential buildings
    Salis, Louis Cony Renaud
    Abadie, Marc
    Wargocki, Pawel
    Rode, Carsten
    ENERGY AND BUILDINGS, 2017, 152 : 492 - 502
  • [7] Ventilation, indoor air quality, and health in homes undergoing weatherization
    Francisco, P. W.
    Jacobs, D. E.
    Targos, L.
    Dixon, S. L.
    Breysse, J.
    Rose, W.
    Cali, S.
    INDOOR AIR, 2017, 27 (02) : 463 - 477
  • [8] Indoor air quality, ventilation and their associations with sick building syndrome in Chinese homes
    Sun, Yuexia
    Hou, Jing
    Cheng, Rongsai
    Sheng, Ying
    Zhang, Xinyu
    Sundell, Jan
    ENERGY AND BUILDINGS, 2019, 197 : 112 - 119
  • [9] The IVAIRE project - a randomized controlled study of the impact of ventilation on indoor air quality and the respiratory symptoms of asthmatic children in single family homes
    Lajoie, P.
    Aubin, D.
    Gingras, V.
    Daigneault, P.
    Ducharme, F.
    Gauvin, D.
    Fugler, D.
    Leclerc, J. -M.
    Won, D.
    Courteau, M.
    Gingras, S.
    Heroux, M. -E.
    Yang, W.
    Schleibinger, H.
    INDOOR AIR, 2015, 25 (06) : 582 - 597
  • [10] Ventilation for good indoor air quality and energy efficiency
    Awbi, Hazim B.
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 277 - 286