Metabolic Profiling of Skeletal Muscle During Ex-Vivo Normothermic Limb Perfusion

被引:2
|
作者
Rohde, Elizabeth [1 ]
Goudarzi, Maryam [4 ]
Madajka, Maria [1 ]
Said, Sayf Al-Deen [1 ]
Ordenana, Carlos [1 ]
Rezaei, Majid [1 ]
Fahradyan, Vahe [1 ]
Pozza, Edoardo Dall [1 ]
Willard, Belinda [4 ]
Brunengraber, Henri [2 ]
Dasarathy, Srinivasan [3 ]
Rampazzo, Antonio [1 ]
Gharb, Bahar Bassiri [1 ]
机构
[1] Cleveland Clin, Dept Plast Surg, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Sch Med, Dept Nutr & Biochem, Cleveland, OH 44106 USA
[3] Cleveland Clin, Dept Pathobiol, Lerner Res Inst, Cleveland, OH 44195 USA
[4] Cleveland Clin, Lerner Res Inst, Prote & Metabol Core, Cleveland, OH 44195 USA
关键词
D O I
10.1093/milmed/usaa268
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Ex vivo normothermic limb perfusion (EVNLP) provides several advantages for the preservation of limbs following amputation: the ability to maintain oxygenation and temperature of the limb close to physiological values, a perfusion solution providing all necessary nutrients at optimal concentrations, and the ability to maintain physiological pH and electrolytes. However, EVNLP cannot preserve the organ viability infinitely. We identified evidence of mitochondrial injury (swelling, elongation, and membrane disruption) after 24 hours of EVNLP of human upper extremities. The goal of this study was to identify metabolic derangements in the skeletal muscle during EVNLP. Materials and Methods: Fourteen human upper extremities were procured from organ donors after family consent. Seven limbs underwent EVNLP for an average of 41.6 +/- 9.4 hours, and seven contralateral limbs were preserved at 4.C for the same amount of time. Muscle biopsies were performed at 24 hours of perfusion, both from the EVNLP and control limbs. Perturbations in the metabolic profiles of the muscle during EVNLP were determined via untargeted liquid chromatography-mass spectrometry (MS) operated in positive and negative electrospray ionization modes, over a mass range of 50 to 750 Da. The data were deconvoluted using the XCMS software and further statistically analyzed using the in-house statistical package, MetaboLyzer. Putative identification of metabolites using exact mass within +/- 7 ppm mass error and MS/MS spectral matching to the mzCloud spectral library were performed via Compound Discoverer v.2.1 (Thermo Scientific, Fremont, CA, USA). We further validated the identity of candidate metabolites by matching the fragmentation pattern of these metabolites to those of their reference pure chemicals. A nonparametric Mann-Whitney U-test was used to compare EVNLP and control group spectral features. Differences were considered significantly different when P-value < 0.05. Results: We detected over 13,000 spectral features of which 58 met the significance criteria with biologically relevant putative identifications. Furthermore we were able to confirm the identities of the ions taurine (P-value: 0.002) and tryptophan (P-value: 0.002), which were among the most significantly perturbed ions at 24 hours between the experimental and control groups. Metabolites belonging to the following pathways were the most perturbed at 24 hours: neuroactive ligand-receptor interaction (P-values: 0.031 and 0.036) and amino acid metabolism, including tyrosine and tryptophan metabolism (P-values: 0.015, 0.002, and 0.017). Taurine abundance decreased and tryptophan abundance increased at 24 hours. Other metabolites also identified at 24 hours included phenylalanine, xanthosine, and citric acid (P-values: 0.002, 0.002, and 0.0152). Discussion: This study showed presence of active metabolism during EVNLP and metabolic derangement toward the end of perfusion, which correlated with detection of altered mitochondrial structure, swelling, and elongation.
引用
收藏
页码:358 / 363
页数:6
相关论文
共 50 条
  • [1] Metabolic Profiling of Steatotic Human Livers during Ex-Vivo Normothermic Machine Perfusion.
    Raigani, S.
    Karimian, N.
    Huang, V.
    Geerts, S.
    Nagpal, S.
    Uygun, K.
    Yarmush, M.
    Yeh, H.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2019, 19 : 746 - 746
  • [2] Ex-vivo liver splitting during normothermic machine perfusion
    Lau, N. -S.
    Ly, M.
    Ewenson, K.
    Ly, H.
    Huang, J. L.
    Chanda, S.
    Wang, C.
    Liu, K.
    McCaughan, G.
    Crawford, M.
    Pulitano, C.
    TRANSPLANTATION, 2022, 106 (8S) : 63 - 63
  • [3] Ex-vivo normothermic liver perfusion: an update
    Vogel, Thomas
    Brockmann, Jens G.
    Friend, Peter J.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2010, 15 (02) : 167 - 172
  • [4] HEPATIC ARTERY RECONSTRUCTION DURING EX-VIVO NORMOTHERMIC LIVER PERFUSION
    Nasralla, David
    Muiesan, Paolo
    Mergental, Hynek
    Butler, Andrew
    Watson, Chris
    Jassem, Wayel
    Imber, Charles
    Ploeg, Rutger
    Friend, Peter
    Perera, Thamara
    TRANSPLANT INTERNATIONAL, 2017, 30 : 257 - 257
  • [5] HEPATIC ARTERY RECONSTRUCTION DURING EX-VIVO NORMOTHERMIC LIVER PERFUSION
    Nasralla, David
    Muiesan, Paolo
    Mergental, Hynek
    Butler, Andrew
    Watson, Chris
    Jassem, Wayel
    Imber, Charles
    Ploeg, Rutger
    Friend, Peter
    Perera, Thamara
    TRANSPLANT INTERNATIONAL, 2017, 30 : 349 - 349
  • [6] Ex-Vivo Normothermic Limb Perfusion With a Hemoglobin-Based Oxygen Carrier Perfusate
    Said, Sayf A.
    Ordenana, Carlos X.
    Rezaei, Majid
    Figueroa, Brian A.
    Dasarathy, Srinivasan
    Brunengraber, Henri
    Rampazzo, Antonio
    Gharb, Bahar Bassiri
    MILITARY MEDICINE, 2020, 185 : 110 - 120
  • [7] The assessment of different oxygen tensions during ex-vivo normothermic kidney perfusion
    Adams, T. D.
    Hosgood, S. A.
    Nicholson, M. L.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 8 - 8
  • [8] LPotential of mitochondrial dysfunction biomarkers during ex-vivo normothermic liver perfusion
    Ali, K.
    Liu, Q.
    Cazzaniga, B.
    Raj, R.
    Tuul, M.
    Uso, T. Diago
    Fujiki, M.
    Aucejo, F.
    Eghtesad, B.
    D'Amico, G.
    Kwon, C. H. D.
    Chaudhry, S.
    Pita, A.
    Kim, J.
    Fairchild, R.
    Doi, J.
    Khalil, M.
    Fernandes, E.
    Kusakabe, J.
    Calderon, E.
    Miller, C.
    Schlegel, A.
    Hashimoto, K.
    Quintini, C.
    TRANSPLANTATION, 2023, 107 (09) : 90 - 90
  • [9] THE PHYSIOLOGICAL EFFECTS OF ALTERING OXYGENATION DURING EX-VIVO NORMOTHERMIC KIDNEY PERFUSION
    Adams, T.
    Hosgood, S.
    Nicholson, M.
    TRANSPLANT INTERNATIONAL, 2018, 31 : 6 - 6
  • [10] Ex-vivo Normothermic Perfusion in Marginal Donor Kidney Transplantation
    Hosgood, S.
    Barlow, A.
    Nicholson, M.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 104 - 105