Multi-center reproducibility of structural, diffusion tensor, and resting state functional magnetic resonance imaging measures

被引:13
作者
Deprez, S. [1 ,2 ]
de Ruiter, Michiel B. [3 ]
Bogaert, S. [4 ]
Peeters, R. [1 ,2 ]
Belderbos, J. [5 ]
De Ruysscher, D. [6 ,7 ]
Schagen, S. [3 ]
Sunaert, S. [1 ,2 ]
Pullens, P. [8 ,9 ]
Achten, E. [4 ]
机构
[1] Univ Hosp Leuven, Dept Radiol, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Imaging & Pathol, Leuven, Belgium
[3] Netherlands Canc Inst, Div Psychosocial Res & Epidemiol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[4] Ghent Univ Hosp, Dept Radiol, Ghent, Belgium
[5] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[6] Maastricht Univ, Med Ctr, GROW Sch, Dept Radiat Oncol,Maastro Clin, Maastricht, Netherlands
[7] Katholieke Univ Leuven, Radiat Oncol, Leuven, Belgium
[8] Univ Hosp Antwerp, Dept Radiol, Edegem, Belgium
[9] Antwerp Univ, Edegem, Belgium
关键词
Multi-center; Reproducibility; Structural MRI; Diffusion tensor imaging; Resting state fMRI; MRI; RELIABILITY; MULTISITE; PHANTOM; BRAIN; CONNECTIVITY; VARIABILITY; ASSURANCE; NOISE; WATER;
D O I
10.1007/s00234-018-2017-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The aim of this study is to assess multi-center reproducibility and longitudinal consistency of MRI imaging measurements, as part of a phase III longitudinal multi-center study comparing the neurotoxic effect following prophylactic cranial irradiation with hippocampal avoidance (HA-PCI), in comparison with conventional PCI in patients with small-cell lung cancer. Methods Harmonized MRI acquisition protocols from six participating sites and two different vendors were compared using both physical and human phantoms. We assessed variability across sites and time points by evaluating various phantoms and data including hippocampal volume, diffusion metrics, and resting-state fMRI, from two healthy volunteers. Results We report average coefficients of variation (CV) below 5% for intrascanner, intravendor, and intervendor reproducibility for both structural and diffusion imaging metrics, except for diffusion metrics obtained from tractography with average CVs ranging up to 7.8%. Additionally, resting-state fMRI showed stable temporal SNR and reliable generation of subjects DMN across vendors and time points. Conclusion These findings indicate that the presented multi-site MRI acquisition protocol can be used in a longitudinal study design and that pooling of the acquired data as part of the phase III longitudinal HA-PCI project is possible with careful monitoring of the results of the half-yearly QA assessment to follow-up on potential scanner-related longitudinal changes in image quality.
引用
收藏
页码:617 / 634
页数:18
相关论文
共 45 条
  • [41] Reproducibility of quantitative tractography methods applied to cerebral white matter
    Wakana, Setsu
    Caprihan, Arvind
    Panzenboeck, Martina M.
    Fallon, James H.
    Perry, Michele
    Gollub, Randy L.
    Hua, Kegang
    Zhang, Jiangyang
    Jiang, Hangyi
    Dubey, Prachi
    Blitz, Ari
    van Zijl, Peter
    Mori, Susumu
    [J]. NEUROIMAGE, 2007, 36 (03) : 630 - 644
  • [42] Quantitative multi-parameter mapping of R1 PD* MT, and R2*at 3T: a multi-center validation
    Weiskopf, Nikolaus
    Suckling, John
    Williams, Guy
    Correia, Marta M.
    Inkster, Becky
    Tait, Roger
    Ooi, Cinly
    Bullmore, Edward T.
    Lutti, Antoine
    [J]. FRONTIERS IN NEUROSCIENCE, 2013, 7
  • [43] Comparing Manual and Automatic Segmentation of Hippocampal Volumes: Reliability and Validity Issues in Younger and Older Brains
    Wenger, Elisabeth
    Martensson, Johan
    Noack, Hannes
    Bodammer, Nils Christian
    Kuehn, Simone
    Schaefer, Sabine
    Heinze, Hans-Jochen
    Duezel, Emrah
    Backman, Lars
    Lindenberger, Ulman
    Lovden, Martin
    [J]. HUMAN BRAIN MAPPING, 2014, 35 (08) : 4236 - 4248
  • [44] A method for calibrating diffusion gradients in diffusion tensor imaging
    Wu, Yu-Chien
    Alexander, Andrew L.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (06) : 984 - 993
  • [45] Quantification of accuracy and precision of multi-center DTI measurements: A diffusion phantom and human brain study
    Zhu, Tong
    Hu, Rui
    Qiu, Xing
    Taylor, Michael
    Tso, Yuen
    Yiannoutsos, Constantin
    Navia, Bradford
    Mori, Susumu
    Ekholm, Sven
    Schifitto, Giovanni
    Zhong, Jianhui
    [J]. NEUROIMAGE, 2011, 56 (03) : 1398 - 1411