Multi-center reproducibility of structural, diffusion tensor, and resting state functional magnetic resonance imaging measures

被引:13
作者
Deprez, S. [1 ,2 ]
de Ruiter, Michiel B. [3 ]
Bogaert, S. [4 ]
Peeters, R. [1 ,2 ]
Belderbos, J. [5 ]
De Ruysscher, D. [6 ,7 ]
Schagen, S. [3 ]
Sunaert, S. [1 ,2 ]
Pullens, P. [8 ,9 ]
Achten, E. [4 ]
机构
[1] Univ Hosp Leuven, Dept Radiol, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Imaging & Pathol, Leuven, Belgium
[3] Netherlands Canc Inst, Div Psychosocial Res & Epidemiol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[4] Ghent Univ Hosp, Dept Radiol, Ghent, Belgium
[5] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[6] Maastricht Univ, Med Ctr, GROW Sch, Dept Radiat Oncol,Maastro Clin, Maastricht, Netherlands
[7] Katholieke Univ Leuven, Radiat Oncol, Leuven, Belgium
[8] Univ Hosp Antwerp, Dept Radiol, Edegem, Belgium
[9] Antwerp Univ, Edegem, Belgium
关键词
Multi-center; Reproducibility; Structural MRI; Diffusion tensor imaging; Resting state fMRI; MRI; RELIABILITY; MULTISITE; PHANTOM; BRAIN; CONNECTIVITY; VARIABILITY; ASSURANCE; NOISE; WATER;
D O I
10.1007/s00234-018-2017-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The aim of this study is to assess multi-center reproducibility and longitudinal consistency of MRI imaging measurements, as part of a phase III longitudinal multi-center study comparing the neurotoxic effect following prophylactic cranial irradiation with hippocampal avoidance (HA-PCI), in comparison with conventional PCI in patients with small-cell lung cancer. Methods Harmonized MRI acquisition protocols from six participating sites and two different vendors were compared using both physical and human phantoms. We assessed variability across sites and time points by evaluating various phantoms and data including hippocampal volume, diffusion metrics, and resting-state fMRI, from two healthy volunteers. Results We report average coefficients of variation (CV) below 5% for intrascanner, intravendor, and intervendor reproducibility for both structural and diffusion imaging metrics, except for diffusion metrics obtained from tractography with average CVs ranging up to 7.8%. Additionally, resting-state fMRI showed stable temporal SNR and reliable generation of subjects DMN across vendors and time points. Conclusion These findings indicate that the presented multi-site MRI acquisition protocol can be used in a longitudinal study design and that pooling of the acquired data as part of the phase III longitudinal HA-PCI project is possible with careful monitoring of the results of the half-yearly QA assessment to follow-up on potential scanner-related longitudinal changes in image quality.
引用
收藏
页码:617 / 634
页数:18
相关论文
共 45 条
  • [11] Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain
    Grech-Sollars, Matthew
    Hales, Patrick W.
    Miyazaki, Keiko
    Raschke, Felix
    Rodriguez, Daniel
    Wilson, Martin
    Gill, Simrandip K.
    Banks, Tina
    Saunders, Dawn E.
    Clayden, Jonathan D.
    Gwilliam, Matt N.
    Barrick, Thomas R.
    Morgan, Paul S.
    Davies, Nigel P.
    Rossiter, James
    Auer, Dorothee P.
    Grundy, Richard
    Leach, Martin O.
    Howe, Franklyn A.
    Peet, Andrew C.
    Clark, Chris A.
    [J]. NMR IN BIOMEDICINE, 2015, 28 (04) : 468 - 485
  • [12] Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements
    Holz, M
    Heil, SR
    Sacco, A
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2000, 2 (20) : 4740 - 4742
  • [13] Reproducibility of Structural, Resting-State BOLD and DTI Data between Identical Scanners
    Huang, Lejian
    Wang, Xue
    Baliki, Marwan N.
    Wang, Lei
    Apkarian, A. Vania
    Parrish, Todd B.
    [J]. PLOS ONE, 2012, 7 (10):
  • [14] The Alzheimer's Disease Neuroimaging Initiative (ADNI): MRI methods
    Jack, Clifford R., Jr.
    Bernstein, Matt A.
    Fox, Nick C.
    Thompson, Paul
    Alexander, Gene
    Harvey, Danielle
    Borowski, Bret
    Britson, Paula J.
    Whitwell, Jennifer L.
    Ward, Chadwick
    Dale, Anders M.
    Felmlee, Joel P.
    Gunter, Jeffrey L.
    Hill, Derek L. G.
    Killiany, Ron
    Schuff, Norbert
    Fox-Bosetti, Sabrina
    Lin, Chen
    Studholme, Colin
    DeCarli, Charles S.
    Krueger, Gunnar
    Ward, Heidi A.
    Metzger, Gregory J.
    Scott, Katherine T.
    Mallozzi, Richard
    Blezek, Daniel
    Levy, Joshua
    Debbins, Josef P.
    Fleisher, Adam S.
    Albert, Marilyn
    Green, Robert
    Bartzokis, George
    Glover, Gary
    Mugler, John
    Weiner, Michael W.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 685 - 691
  • [15] Jones DK., 2011, DIFFUSION MRI THEORY
  • [16] Jones R.B. Payne., 1997, Clinical investigation and statistics in laboratory medicine
  • [17] Reliability in multi-site structural MRI studies: Effects of gradient non-linearity correction on phantom and human data
    Jovicich, J
    Czanner, S
    Greve, D
    Haley, E
    van der Kouwe, A
    Gollub, R
    Kennedy, D
    Schmitt, F
    Brown, G
    MacFall, J
    Fischl, B
    Dale, A
    [J]. NEUROIMAGE, 2006, 30 (02) : 436 - 443
  • [18] Longitudinal reproducibility of default-mode network connectivity in healthy elderly participants: A multicentric resting-state fMRI study
    Jovicich, Jorge
    Minati, Ludovico
    Marizzoni, Moira
    Marchitelli, Rocco
    Sala-Llonch, Roser
    Bartres-Faz, David
    Arnold, Jennifer
    Benninghoff, Jens
    Fiedler, Ute
    Roccatagliata, Luca
    Picco, Agnese
    Nobili, Flavio
    Blin, Oliver
    Bombois, Stephanie
    Lopes, Renaud
    Bordet, Regis
    Sein, Julien
    Ranjeva, Jean-Philippe
    Didic, Mira
    Gros-Dagnac, Helene
    Payoux, Pierre
    Zoccatelli, Giada
    Alessandrini, Franco
    Beltramello, Alberto
    Bargallo, Nuria
    Ferretti, Antonio
    Caulo, Massimo
    Aiello, Marco
    Cavaliere, Carlo
    Soricelli, Andrea
    Parnetti, Lucilla
    Tarducci, Roberto
    Floridi, Piero
    Tsolaki, Magda
    Constantinidis, Manos
    Drevelegas, Antonios
    Rossini, Paolo Maria
    Marra, Camillo
    Schoenknecht, Peter
    Hensch, Tilman
    Hoffmann, Karl-Titus
    Kuijer, Joost P.
    Visser, Pieter Jelle
    Barkhof, Frederik
    Frisoni, Giovanni B.
    [J]. NEUROIMAGE, 2016, 124 : 442 - 454
  • [19] Multisite longitudinal reliability of tract-based spatial statistics in diffusion tensor imaging of healthy elderly subjects
    Jovicich, Jorge
    Marizzoni, Moira
    Bosch, Beatriz
    Bartres-Faz, David
    Arnold, Jennifer
    Benninghoff, Jens
    Wiltfang, Jens
    Roccatagliata, Luca
    Picco, Agnese
    Nobili, Flavio
    Blini, Oliver
    Bombois, Stephanie
    Lopes, Renaud
    Bordet, Regis
    Chanoine, Valerie
    Ranjeva, Jean-Philippe
    Didic, Mira
    Gros-Dagnac, Helene
    Payoux, Pierre
    Zoccatelli, Giada
    Alessandrini, Franco
    Beltramello, Alberto
    Bargallo, Nria
    Ferretti, Antonio
    Caulo, Massimo
    Aiellou, Marco
    Ragucci, Monica
    Soricelli, Andrea
    Salvadori, Nicola
    Tarducci, Roberto
    Floridi, Piero
    Tsolaki, Magda
    Constantinidis, Manos
    Drevelegas, Antonios
    Rossini, Paolo Maria
    Marra, Camillo
    Otto, Josephin
    Reiss-Zimmermann, Martin
    Hoffmann, Karl-Titus
    Galluzzi, Samantha
    Frisoni, Giovanni B.
    [J]. NEUROIMAGE, 2014, 101 : 390 - 403
  • [20] Brain morphometry reproducibility in multi-center 3 T MRI studies: A comparison of cross-sectional and longitudinal segmentations
    Jovicich, Jorge
    Marizzoni, Moira
    Sala-Llonch, Roser
    Bosch, Beatriz
    Bartres-Faz, David
    Arnold, Jennifer
    Benninghoff, Jens
    Wiltfang, Jens
    Roccatagliata, Luca
    Nobili, Flavio
    Hensch, Tilman
    Traenkner, Anja
    Schoenknecht, Peter
    Leroy, Melanie
    Lopes, Renaud
    Bordet, Regis
    Chanoine, Valerie
    Ranjeva, Jean-Philippe
    Didic, Mira
    Gros-Dagnac, Helene
    Payoux, Pierre
    Zoccatelli, Giada
    Alessandrini, Franco
    Beltramello, Alberto
    Bargallo, Nurai
    Blin, Olivier
    Frisoni, Giovanni B.
    [J]. NEUROIMAGE, 2013, 83 : 472 - 484