Benefit of replanning in MR-guided online adaptive radiation therapy in the treatment of liver metastasis

被引:32
|
作者
Mayinger, Michael [1 ]
Ludwig, Roman [1 ]
Christ, Sebastian M. [1 ]
Dal Bello, Riccardo [1 ]
Ryu, Alex [1 ]
Weitkamp, Nienke [1 ]
Pavic, Matea [1 ]
Schueler, Helena Garcia [1 ]
Wilke, Lotte [1 ]
Guckenberger, Matthias [1 ]
Unkelbach, Jan [1 ]
Tanadini-Lang, Stephanie [1 ]
Andratschke, Nicolaus [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Radiat Oncol, Raemistr 100, D-8091 Zurich, Switzerland
关键词
STEREOTACTIC BODY RADIOTHERAPY; CELL LUNG-CANCER; TRIAL; OUTCOMES;
D O I
10.1186/s13014-021-01813-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To assess the effects of daily adaptive MR-guided replanning in stereotactic body radiation therapy (SBRT) of liver metastases based on a patient individual longitudinal dosimetric analysis. Methods Fifteen patients assigned to SBRT for oligometastatic liver metastases underwent daily MR-guided target localization and on-table treatment plan re-optimization. Gross tumor volume (GTV) and organs at risk (OARs) were adapted to the anatomy-of-the-day. A reoptimized plan (RP) and a rigidly shifted baseline plan (sBP) without re-optimization were generated for each fraction. After extraction of DVH parameters for GTV, planning target volume (PTV), and OARs (stomach, duodenum, bowel, liver, heart) plans were compared on a per-patient basis. Results Median pre-treatment GTV and PTV were 14.9 cc (interquartile range (IQR): 7.7-32.9) and 62.7 cc (IQR: 42.4-105.5) respectively. SBRT with RP improved PTV coverage (V100%) for 47/75 of the fractions and reduced doses to the most proximal OARs (D1cc, Dmean) in 33/75 fractions compared to sBP. RP significantly improved PTV coverage (V100%) for metastases within close proximity to an OAR by 4.0% (<= 0.2 cm distance from the edge of the PTV to the edge of the OAR; n = 7; p = 0.01), but only by 0.2% for metastases farther away from OAR (> 2 cm distance; n = 7; p = 0.37). No acute grade 3 treatment-related toxicities were observed. Conclusions MR-guided online replanning SBRT improved target coverage and OAR sparing for liver metastases with a distance from the edge of the PTV to the nearest luminal OAR < 2 cm. Only marginal improvements in target coverage were observed for target distant to critical OARs, indicating that these patients do not benefit from daily adaptive replanning.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Retrospective study comparing MR-guided radiation therapy (MRgRT) setup strategies for prostate treatment: repositioning vs. replanning
    Kim, Jung-in
    Park, Jong Min
    Choi, Chang Heon
    An, Hyun Joon
    Kim, Yi-Jun
    Kim, Jin Ho
    RADIATION ONCOLOGY, 2019, 14 (01)
  • [22] Practical guidelines of online MR-guided adaptive radiotherapy
    Okamoto, Hiroyuki
    Igaki, Hiroshi
    Chiba, Takahito
    Shibuya, Keiko
    Sakasai, Tatsuya
    Jingu, Keiichi
    Inaba, Koji
    Kuroda, Kagayaki
    Aoki, Shigeki
    Tatsumi, Daisaku
    Nakamura, Mitsuhiro
    Kadoya, Noriyuki
    Furuyama, Yoshinobu
    Kumazaki, Yu
    Tohyama, Naoki
    Tsuneda, Masato
    Nishioka, Shie
    Itami, Jun
    Onishi, Hiroshi
    Shigematsu, Naoyuki
    Uno, Takashi
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (05) : 730 - 740
  • [23] A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac
    Chen, Xinfeng
    Ahunbay, Ergun
    Paulson, Eric S.
    Chen, Guangpei
    Li, X. Allen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 205 - 212
  • [24] Image-guided Radiation Therapy: Emergence of MR-Guided Radiation Treatment (MRgRT) Systems
    Jaffray, D. A.
    Carlone, M.
    Menard, C.
    Breen, S.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [25] Stereotactic MR-guided Online Adaptive Radiation Therapy with High Dose Rate (SMART-HDR) Brachytherapy
    Mittauer, K. E.
    Miller, J.
    Bradley, K. A.
    Bayouth, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S182 - S182
  • [26] Commissioning of an MR-Guided Radiation Therapy System
    Stanescu, T.
    Tadic, T.
    Jaffray, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S94 - S95
  • [27] Implementation of patient specific QA for daily adaptive MR-guided radiation therapy
    Palacios, M. A.
    Apicella, T.
    Hoffmans, D.
    Osario, T. R.
    Admiraal, M.
    Kawrakow, I.
    Cuijpers, J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S134 - S135
  • [28] Phase I trial of stereotactic MR-guided online adaptive radiation therapy (SMART) for the treatment of oligometastatic or unresectable primary malignancies of the abdomen
    Henke, Lauren
    Kashani, Rojano
    Robinson, Clifford
    Curcuru, Austen
    DeWees, Todd
    Bradley, Jeffrey
    Green, Olga
    Michalski, Jeff
    Mutic, Sasa
    Parikh, Parag
    Olsen, Jeffrey
    RADIOTHERAPY AND ONCOLOGY, 2018, 126 (03) : 519 - 526
  • [29] Standardization of Stereotactic MR-Guided Adaptive Radiation Therapy Planning for Prostate Cancer
    Drabble, J.
    Wai, P.
    Chauhan, J.
    Chinherende, E.
    Maungwe, P.
    Murray, D.
    Harford-Wright, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E379 - E380
  • [30] Clinical experience with stereotactic MR-guided adaptive radiation therapy for pancreatic tumors
    Bruynzeel, A.
    Lagerwaard, F.
    Bohoudi, O.
    Tetar, S.
    Haasbeek, N.
    Oei, S. S.
    Slotman, B.
    Meijerink, M.
    Senan, S.
    Palacios, M.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S224 - S225