Long term reliability of EMG measurements in adults with cystic fibrosis

被引:12
作者
Gruet, M. [3 ]
Vallier, J. M. [3 ]
Mely, L. [2 ]
Brisswalter, J. [1 ,3 ]
机构
[1] Univ Nice Sophia Antipolis, LAHMES, F-06205 Nice 3, France
[2] Hosp Civils Lyon, Hop Renee Sabran, Ctr Ressources & Competences Mucoviscidose, Lyon, France
[3] Univ Toulon Var, EA 4322, Sport Ergon & Performance Lab, Toulon, France
关键词
Electromyography; Spectrum analysis; Cystic fibrosis; Reliability; Muscle fatigue; PERIPHERAL MUSCLE DYSFUNCTION; QUADRICEPS MUSCLES; SURFACE EMG; VOLUNTARY CONTRACTIONS; CONDUCTION-VELOCITY; MEDIALIS OBLIQUUS; SPECTRAL-ANALYSIS; EXERCISE; FATIGUE; PARAMETERS;
D O I
10.1016/j.jelekin.2009.05.001
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of this study was to investigate the long term reliability of surface electromyography (sEMG) measurements in adults with cystic fibrosis (CF). Eighteen healthy subjects (CO) and sixteen adults with CF were tested on two occasions, six weeks apart. sEMG was recorded from the rectus femoris, vastus lateralis and vastus medialis obliquus muscles during maximal voluntary contraction (MVC) and 50% MVC until exhaustion. Quadriceps muscle activity during 50% MVC was described using four measures (initial, final, normalized and slope values) for both frequency and time domain. Relative (ICC) and absolute (SEM) reliabilities were applied to asses test-retest reliability. In CF group, median frequency (MDF) values for 100% MVC and initial, final and normalized final MDF for 50% MVC demonstrated moderate to very high relative reliability (ICC = 0.60-0.91) and low variability (SEM = 5.5-13%). MDF slope showed large variability in both groups. Root mean square (RMS) values were not reproducible in both groups whatever the intensity of exercise and can not be recommended as outcomes parameters. In conclusion, sEMG measurements during maximal and submaximal isometric contractions could be valid and reliable tools for clinical applications in cystic fibrosis patients but mainly in the frequency domain and from rectus femoris. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:305 / 312
页数:8
相关论文
共 66 条
  • [1] Systemic effects of chronic obstructive pulmonary disease
    Agustí, AGN
    Noguera, A
    Sauleda, J
    Sala, E
    Pons, J
    Busquets, X
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2003, 21 (02) : 347 - 360
  • [2] [Anonymous], 1997, CLIN PRACTICE GUIDEL
  • [3] Changes in intracellular action potential profile affect parameters used in turns/amplitude analysis
    Arabadzhiev, Todor I.
    Dimitrov, George V.
    Chakarov, Vichren E.
    Dimitrov, Alexander G.
    Dimitrova, Nonna A.
    [J]. MUSCLE & NERVE, 2008, 37 (06) : 713 - 720
  • [4] Basmajian J., 1985, MUSCLE ALIVE THEIR F, V5th ed.
  • [5] Assessing reproducibility of data obtained with instruments based on continuous measurements
    Bédard, M
    Martin, NJ
    Krueger, P
    Brazil, K
    [J]. EXPERIMENTAL AGING RESEARCH, 2000, 26 (04) : 353 - 365
  • [6] MOTOR UNIT RECRUITMENT STRATEGY OF KNEE ANTAGONIST MUSCLES IN A STEP-WISE, INCREASING ISOMETRIC CONTRACTION
    BERNARDI, M
    SOLOMONOW, M
    SANCHEZ, JH
    BARATTA, RV
    NGUYEN, G
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 70 (06): : 493 - 501
  • [7] Bernardi M, 1997, Electromyogr Clin Neurophysiol, V37, P3
  • [8] CHANGES IN MUSCLE CONTRACTILE PROPERTIES AND NEURAL CONTROL DURING HUMAN MUSCULAR FATIGUE
    BIGLANDRITCHIE, B
    WOODS, JJ
    [J]. MUSCLE & NERVE, 1984, 7 (09) : 691 - 699
  • [9] FATIGUE OF INTERMITTENT SUBMAXIMAL VOLUNTARY CONTRACTIONS - CENTRAL AND PERIPHERAL FACTORS
    BIGLANDRITCHIE, B
    FURBUSH, F
    WOODS, JJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) : 421 - 429
  • [10] Bilodeau M, 1994, Electromyogr Clin Neurophysiol, V34, P149