Factors affecting accuracy and precision in ultrasound guided radiotherapy

被引:4
|
作者
Grimwood, Alexander [1 ,2 ,3 ]
Thomas, Karen [2 ,4 ]
Kember, Sally [1 ,2 ]
Aldis, Georgina [1 ,2 ]
Lawes, Rebekah [1 ,2 ]
Brigden, Beverley [1 ,2 ]
Francis, Jane [1 ,2 ]
Henegan, Emer [1 ,2 ]
Kerner, Melanie [1 ,2 ]
Delacroix, Louise [1 ,2 ]
Gordon, Alexandra [1 ,2 ]
Tree, Alison [1 ,2 ]
Harris, Emma J. [1 ,2 ,3 ]
McNair, Helen A. [1 ,2 ]
机构
[1] Royal Marsden NHS Fdn Trust, Dept Radiotherapy, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Fdn Trust, Radiotherapy Dept, Inst Canc Res, Sutton SM2 5PT, Surrey, England
[3] Royal Marsden NHS Fdn Trust, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[4] Royal Marsden NHS Fdn Trust, Dept Stat & Comp, Sutton SM2 5PT, Surrey, England
关键词
Prostate cancer; Inter observer error; Ultrasound; Treatment margins; Image guidance; EXTERNAL-BEAM RADIOTHERAPY; LOCALIZED PROSTATE-CANCER; TRANSPERINEAL ULTRASOUND; RADIATION-THERAPY; MOTION; ONLINE; VERIFICATION; MARKERS; ERRORS; IRRADIATION;
D O I
10.1016/j.phro.2021.05.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Transperineal ultrasound (TPUS) is used clinically for directly assessing prostate motion. Factors affecting accuracy and precision in TPUS motion estimation must be assessed to realise its full potential. Methods and materials: Patients were imaged using volumetric TPUS during the Clarity-Pm trial (NCT02388308). Prostate motion was measured online at patient set-up and offline by experienced observers. Cone beam CT with markers was used as a comparator and observer performance was also quantified. The influence of different clinical factors was examined to establish specific recommendations towards efficacious ultrasound guided radiotherapy. Results: From 330 fractions in 22 patients, offline observer random errors were 1.5 mm, 1.3 mm, 1.9 mm (left-right, superior-inferior, anteroposterior respectively). Errors increased in fractions exhibiting poor image quality to 3.3 mm, 3.3 mm and 6.8 mm. Poor image quality was associated with inconsistent probe placement, large anatomical changes and unfavourable imaging conditions within the patient. Online matching exhibited increased observer errors of: 3.2 mm, 2.9 mm and 4.7 mm. Four patients exhibited large systematic residual errors, of which three had poor quality images. Patient habitus showed no correlation with observer error, residual error, or image quality. Conclusions: TPUS offers the unique potential to directly assess inter- and intra-fraction motion on conventional linacs. Inconsistent image quality, inexperienced operators and the pressures of the clinical environment may degrade precision and accuracy. Experienced operators are essential and cross-centre standards for training and QA should be established that build upon current guidance. Greater use of automation technologies may further minimise uncertainties.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 50 条
  • [1] FACTORS AFFECTING ACCURACY AND PRECISION IN PET VOLUME IMAGING
    KARP, JS
    DAUBEWITHERSPOON, ME
    MUEHLLEHNER, G
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (02): : A38 - A44
  • [2] PRECISION AND ACCURACY IN RADIOTHERAPY
    BRENNER, DJ
    RADIOTHERAPY AND ONCOLOGY, 1989, 14 (02) : 159 - 162
  • [3] Factors affecting the accuracy and precision of quantitative description of materials microstructure
    Cwajna, J
    BULK AND GRADED NANOMETALS, 2005, 101-102 : 297 - 306
  • [4] FACTORS AFFECTING PRECISION AND ACCURACY IN AUTOMATED GPC DATA REDUCTION
    CLEMOW, TH
    LIMPERT, RJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (SEP): : 90 - 90
  • [5] Factors affecting the outcome of transrectal ultrasound guided prostate biopsy
    Fones, D.
    Chia, S. J.
    BJU INTERNATIONAL, 2017, 119 : 33 - 33
  • [6] PRECISION AND ACCURACY IN RADIOTHERAPY - REPLY
    MIJNHEER, BJ
    BATTERMANN, JJ
    WAMBERSIE, A
    RADIOTHERAPY AND ONCOLOGY, 1989, 14 (02) : 163 - 167
  • [7] The analysis of affecting factors on the application accuracy of interactive image guided surgery
    Li, QH
    Jiang, ZW
    Zamorano, L
    Buciuc, R
    Gong, JX
    Diaz, F
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 757 - 760
  • [8] ACCURACY OF ENDOSCOPIC ULTRASOUND FOR SUPERFICIAL ESOPHAGEAL CANCER AND FACTORS AFFECTING OVERSTAGING
    Choi, Jinju
    Chung, Hyunsoo
    Lee, Ayoung
    Kim, Jue L.
    Cho, Soo-Jeong
    Kim, Sang Gyun
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB325 - AB326
  • [10] A STUDY OF FACTORS AFFECTING PRECISION AND ACCURACY OF THYROXINE (T4) DETERMINATIONS
    HANOK, A
    KUO, J
    KUHN, J
    TRIVELLI, L
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1970, 54 (04) : 542 - &