Energy and exergy analysis on hydrofluoroolefin/ hydrofluorocarbon (HFO/HFC) refrigerant mixtures in low and medium temperature small-scale refrigeration systems

被引:8
作者
Raveendran, P. Saji [1 ]
Sekhar, S. Joseph [2 ]
机构
[1] Kongu Engn Coll, Dept Mech Engn, Perundurai 638052, Erode, India
[2] Shinas Coll Technol, Dept Engn, Mech Sect, Shinas, Oman
关键词
HFO-1234yf; HFO-1234ze; refrigerant mixtures; exergy; MATLab; R134A; PERFORMANCE; R1234YF; REPLACEMENT; HFC134A;
D O I
10.1177/0954408919881306
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The new refrigerants such as HFO-1234yf and HFO-1234ze have been considered as long-term replacements for HFC-134a to comply with the Kyoto protocol. In small size refrigeration systems, these refrigerants have poor performance than HFC-134a besides their minor flammability. Previous studies reveal that the addition of HFC-134a in small quantity can improve the performance of a system without exceeding the global warming potential limit (150) prescribed by the European Union. However, this concept is not studied in small-scale refrigerators. Therefore, the performance of low and medium temperature systems of capacity 190 and 285 litre, respectively, working with different hydrofluoroolefin/ hydrofluorocarbon (HFO/HFC) mixtures, has been studied by mathematical simulation. The software tool 'MATLab' and the refrigerant property database 'REFPROP' have been used in the simulation. The results showed that the coefficient of performance (COP) of Hydrofluoroolefin (HFO) refrigerants and its mixtures decreases from 2.4 to 15.7% than that of HFC-134a. Among the mixtures, HFO-1234ze/HFC-134a (90/10) shows better performance and its predicted coefficient of performance (COP) and exergetic efficiency are 4-8.3% and 5.1-10.5%, respectively, higher than that of other mixtures considered in this study.
引用
收藏
页码:718 / 730
页数:13
相关论文
共 34 条
[21]   Experimental analysis of R1234yf as a drop-in replacement for R134a in a vapor compression system [J].
Navarro-Esbri, J. ;
Mendoza-Miranda, J. M. ;
Mota-Babiloni, A. ;
Barragan-Cervera, A. ;
Belman-Flores, J. M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03) :870-880
[22]   Atmospheric chemistry of CF3CF=CH2:: Kinetics and mechanisms of gas-phase reactions with Cl atoms, OH radicals, and O3 [J].
Nielsen, O. J. ;
Javadi, M. S. ;
Sulbaek Andersen, M. P. ;
Hurley, M. D. ;
Wallington, T. J. ;
Singh, R. .
CHEMICAL PHYSICS LETTERS, 2007, 439 (1-3) :18-22
[23]  
Padhy SK, 1992, P INT COMPR ENG C, P405
[24]  
Perry R H., 1984, PERRYS CHEM ENG HDB
[25]  
Qiu J, 2014, 15 INT REFR AIR COND
[26]   Investigation on the energy and exergy efficiencies of a domestic refrigerator retrofitted with water-cooled condensers of shell-and-coil and brazed-plate heat exchangers [J].
Raveendran, P. Saji ;
Sekhar, S. Joseph .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (01) :381-388
[27]   Exergy analysis of a domestic refrigerator with brazed plate heat exchanger as condenser [J].
Raveendran, P. Saji ;
Sekhar, S. Joseph .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2017, 127 (03) :2439-2446
[28]   Performance studies on a domestic refrigerators retrofitted with building-integrated water-cooled condenser [J].
Raveendran, P. Saji ;
Sekhar, S. Joseph .
ENERGY AND BUILDINGS, 2017, 134 :1-10
[29]   Exergetic analysis of a vapour compression refrigeration system with R134a, R143a, R152a, R404A, R407C, R410A, R502 and R507A [J].
Reddy, V. Siva ;
Panwar, N. L. ;
Kaushik, S. C. .
CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2012, 14 (01) :47-53
[30]   TFA from HFO-1234yf: Accumulation and aquatic risk in terminal water bodies [J].
Russell, Mark H. ;
Hoogeweg, Gerco ;
Webster, Eva M. ;
Ellis, David A. ;
Waterland, Robert L. ;
Hoke, Robert A. .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2012, 31 (09) :1957-1965