Clinical and radiological results of hydroxyapatite-coated acetabular cups

被引:3
|
作者
Blacha, J [1 ]
Gagala, J [1 ]
机构
[1] Univ Hosp Nr 4, Med Acad Lublin, Orthopaed & Traumatol Dept, PL-20951 Lublin, Poland
关键词
D O I
10.1007/s00264-004-0563-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We prospectively studied a consecutive series of 60 primary total hip arthroplasties in 52 patients. All patients had a hydroxyapatite-coated hemispherical acetabular cup (OCTOFIT). Mean patient age was 52.5 (34-73) years. In 38 hips, a 28-mm and in 22 hips a 32-mm diameter cobalt-chrome femoral head was used. We could follow 53 hips for a mean of 81 (28-125) months. Four cups were revised because of osteolysis, and in another six cups, slight osteolysis without migration was seen. The average annual linear wear rate was 0.05 mm ( +/- 0.05) for 28-mm heads and 0.16 mm ( +/- 0.09) for 32-mm heads (p<0.000 1). Survivorship analysis predicted a survival rate of 86 +/- 6.7% at 10 years.
引用
收藏
页码:362 / 365
页数:4
相关论文
共 50 条
  • [1] Clinical and radiological results of hydroxyapatite-coated acetabular cups
    J. Blacha
    J. Gągała
    International Orthopaedics, 2004, 28 : 362 - 365
  • [2] Retrieval study on hydroxyapatite-coated acetabular cups
    Hu, WP
    Lai, KA
    Lin, CH
    Yang, CY
    Chang, GL
    PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 5 - 6
  • [3] Failure of dual radius hydroxyapatite-coated acetabular cups
    D'Angelo F.
    Molina M.
    Riva G.
    Zatti G.
    Cherubino P.
    Journal of Orthopaedic Surgery and Research, 3 (1)
  • [4] Early failure of hemispheric hydroxyapatite-coated acetabular cups
    Kim, Shin-Yoon
    Kim, Do-Heon
    Kim, Yong-Goo
    Oh, Chang-Wug
    Ihn, Joo-Chul
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (446) : 233 - 238
  • [5] Aseptic loosening of 2 rim-fix, hydroxyapatite-coated acetabular cups
    Benkö, TZ
    Santiago-Martin, A
    Ruddlesdin, C
    Selzer, G
    JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 519 - 523
  • [6] The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups -: From the Norwegian Arthroplasty Register
    Havelin, LI
    Espehaug, B
    Engesæter, LB
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (06): : 839 - 845
  • [7] Cementless hemispheric hydroxyapatite-coated sockets for acetabular revision
    Geerdink, Carel H.
    Schaafsma, Jelle
    Meyers, Will G. M.
    Grimm, Bernd
    Tonino, Alphons J.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (03): : 369 - 376
  • [8] Survival of hydroxyapatite-coated cups: acetabular screws involve a lower rate of revision surgery due to aseptic loosening
    Natera, Luis
    Valera, Marius
    Moya Gomez, Esther
    Ibanez, Natalia
    Crusi, Xavier
    Sancho, Rogelio
    HIP INTERNATIONAL, 2017, 27 (02) : 153 - 161
  • [9] Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty
    T. Gosens
    E. J. van Langelaan
    International Orthopaedics, 2005, 29 : 219 - 223
  • [10] Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty
    Gosens, T
    van Langelaan, EJ
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (04) : 219 - 223