Two-phase hollow fiber-liquid microextraction based on reverse micelle for the determination of quercetin in human plasma and vegetables samples

被引:53
作者
Banforuzi, Samereh Ranjbar [1 ]
Hadjmohammadi, Mohammad Reza [1 ]
机构
[1] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Niroo Havayii Blvd, Babol Sar 4741695447, Iran
关键词
Hallow fiber-liquid phase microextraction; High performance liquid chromatography; Human plasma; Quercetin; Reverse micelle; Vegetables; SOLID-PHASE EXTRACTION; ALLIUM-CEPA L; HUMAN URINE; FLAVONOIDS; ONION; HPLC; CHROMATOGRAPHY; GLUCOSIDES; ANTIOXIDANT; INHIBITION;
D O I
10.1016/j.talanta.2017.05.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new two-phase hollow fiber-liquid microextraction based on reverse micelle as sensitive and efficient method for the extraction of quercetin in human plasma, onion and tomato samples was developed for the first time. The extraction is based on the solubilization of analyte in the aqueous core of the reverse micelle of cationic cethyltrimethyl ammonium bromide surfactant, CTAB, which are present in the organic phase and are used as acceptor phase in hollow fiber-liquid phase microextraction. Experimental results show that the electrostatic interaction between the oppositely charged surfactant head group present in the reverse micelles and the analyte molecule has a key role in the extraction. Extraction parameters including the organic phase, pH, surfactant concentrations, stirring rate, extraction time, temperature and ionic strength were optimized. The optimum condition is obtained when the variables are set to: pH= 7.5, organic solvent= 1-octanol, CTAB concentration= 7 mmollrl, stirring rate= 900 rpm at room temperature and extraction time= 30 min. Under the mentioned condition, the calibration range was found to be linear over 0.5-1000 ng mL(-1) with the limit of detection of 0.1 ng mL(-1). The extraction recovery of 97.4%, with relative standard deviation of 3.5%, was obtained via tree replicated measurements on a 15 ng L-1 quercetin standard solution. Finally, the newly developed method was successfully used for the preconcentration and determination of quercetin in plasma, onion and tomato samples.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 38 条
  • [1] SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS
    ARTHUR, CL
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (19) : 2145 - 2148
  • [2] Separation/preconcentration and determination of quercetin in food samples by dispersive liquid-liquid microextraction based on solidification of floating organic drop -flow injection spectrophotometry
    Asadollahi, Tahereh
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    Amirkavei, Mooud
    [J]. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2015, 52 (02): : 1103 - 1109
  • [3] Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
  • [4] 2-4
  • [5] Flavonoids as potential protective agents against photo-oxidative skin damage
    Bonina, F
    Lanza, M
    Montenegro, L
    Puglisi, C
    Tomaino, A
    Trombetta, D
    Castelli, F
    Saija, A
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 145 (1-2) : 87 - 94
  • [6] Health effects of quercetin: From antioxidant to nutraceutical
    Boots, Agnes W.
    Haenen, Guido R. M. M.
    Bast, Aalt
    [J]. EUROPEAN JOURNAL OF PHARMACOLOGY, 2008, 585 (2-3) : 325 - 337
  • [7] Profiling and quantifying quercetin glucosides in onion (Allium cepa L.) varieties using capillary zone electrophoresis and high performance liquid chromatography
    Caridi, Domenico
    Trenerry, V. Craige
    Rochfort, Simone
    Duong, Samantha
    Laugher, Dianne
    Jones, Rod
    [J]. FOOD CHEMISTRY, 2007, 105 (02) : 691 - 699
  • [8] INHIBITION OF HUMAN LENS ALDOSE REDUCTASE BY FLAVONOIDS, SULINDAC AND INDOMETHACIN
    CHAUDHRY, PS
    CABRERA, J
    JULIANI, HR
    VARMA, SD
    [J]. BIOCHEMICAL PHARMACOLOGY, 1983, 32 (13) : 1995 - 1998
  • [9] DELALASTRA CA, 1994, PHARMACOLOGY, V48, P56
  • [10] Validated method for the quantitation of quercetin from human plasma using high-performance liquid chromatography with electrochemical detection
    Erlund, I
    Alfthan, G
    Siren, H
    Ariniemi, K
    Aro, A
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2): : 179 - 189