Therapeutic monitoring of amiodarone and desethylamiodarone after surgical ablation of atrial fibrillation-evaluation of the relationship between clinical effect and the serum concentration

被引:1
|
作者
Hrudikova, Erika [1 ,2 ]
Grundmann, Milan [1 ]
Kolek, Martin [3 ,4 ]
Urinovska, Romana [1 ,2 ]
Kacirova, Ivana [1 ,2 ]
机构
[1] Univ Ostrava, Fac Med, Dept Clin Pharmacol, Syllabova 19, Ostrava 70300, Czech Republic
[2] Univ Hosp Ostrava, Dept Clin Pharmacol, Dept Lab Med, 17 Listopadu 1790, Ostrava 70852, Czech Republic
[3] Univ Ostrava, Fac Med, Dept Clin Subjects, Syllabova 19, Ostrava 70300, Czech Republic
[4] Univ Hosp Ostrava, Dept Cardiac Surg, 17 Listopadu 1790, Ostrava 70852, Czech Republic
关键词
Amiodarone; Atrial fibrillation; Desethylamiodarone; Maze procedure; Serum concentration; Sinus rhythm; EXPERT CONSENSUS STATEMENT; EFFICACY; SUPPRESSION; MANAGEMENT; CATHETER; PLASMA;
D O I
10.1016/j.jsps.2021.03.004
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Association between clinical effect and serum concentration of amiodarone (AMI) and its active metabolite desethylamidarone (DEA) in patients after surgical ablation (SA) of atrial fibrillation (AF) has not yet been studied. Aims: We wanted to find a correlation between AMI and DEA serum concentration and maintaining sinus rhythm (SR) after SA of AF. Methods: Sixty eight patients with AF who had undergone surgical ablation between 2014 and 2017 were included in a single-centre, prospective, observational study. Maintaining of SR was evaluated by standard 12-lead ECG and 24-hour Holter ECG monitoring at months 1, 3, 6 and 12 following surgery. Therapeutic monitoring of AMI and DEA concentrations was done to optimize therapy and adverse effects were followed up. Results: We have noticed a high success rate in maintaining of SR (overall 83%). The median of serum concentration of AMI was 0.81 mg/L (range 0.16-2.35 mg/L) and DEA 0.70 mg/l (range 0.19-2.63 mg/L). No significant differences were found in the serum concentratration of AMI, DEA or DEA/AMI concentratration ratios between patients with SR and persistent supraventricular tachyarrhythmia except on the second outpatient visit. We observed significant correlation between serum concentration of DEA and thyroid-stimulating hormone elevation. Conclusion: We confirmed the efficacy of AMI and DEA at the measured serum concentrations. However, analysis of these concentrations alone cannot replace assessment of the clinical response for treatment. Establishment of individual AMI (and DEA) concentrations at which the optimal therapeutic response is achieved seems to be advantageous. Therapeutic monitoring of AMI and DEA is helpful in personalised pharmacotherapy after SA of AF. (c) 2021 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:369 / 376
页数:8
相关论文
共 50 条
  • [41] Relationship between coronary blood flow and improvement of cardiac function after catheter ablation for persistent atrial fibrillation
    Masao Takahashi
    Tomoyuki Arai
    Takashi Kimura
    Rintaro Hojo
    Masayasu Hiraoka
    Seiji Fukamizu
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 2063 - 2070
  • [42] Close relationship between the bronchi and pulmonary veins: Implications for the prevention of atriobronchial fistula after atrial fibrillation ablation
    Wu, Mei-Han
    Wongcharoen, Wanwarang
    Tsao, Hsuan-Ming
    Tai, Ching-Tai
    Chang, Shih-Lin
    Lin, Yenn-Jiang
    Sheu, Ming-Huei
    Chang, Cheng-Yen
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (10) : 1056 - 1059
  • [43] Relationship between coronary blood flow and improvement of cardiac function after catheter ablation for persistent atrial fibrillation
    Takahashi, Masao
    Arai, Tomoyuki
    Kimura, Takashi
    Hojo, Rintaro
    Hiraoka, Masayasu
    Fukamizu, Seiji
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (09) : 2063 - 2070
  • [44] Recurrence rate of atrial fibrillation after the first clinical episode: A prospective evaluation using continuous cardiac rhythm monitoring
    Simantirakis, Emmanuel N.
    Papakonstantinou, Panteleimon E.
    Kanoupakis, Emmanuel
    Chlouverakis, Gregory I.
    Tzeis, Stylianos
    Vardas, Panos E.
    CLINICAL CARDIOLOGY, 2018, 41 (05) : 594 - 600
  • [45] Does the amount of atrial mass reduction improve clinical outcomes after radiofrequency catheter ablation for long-standing persistent atrial fibrillation? Comparison between linear ablation and defragmentation
    Han, Seong Woo
    Shin, Seung Yong
    Im, Sung Il
    Na, Jin Oh
    Choi, Cheol Ung
    Kim, Seong Hwan
    Kim, Jin Won
    Kim, Eung Ju
    Rha, Seung-Woon
    Park, Chang Gyu
    Seo, Hong Seog
    Oh, Dong Joo
    Hwang, Chun
    Lim, Hong Euy
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 171 (01) : 37 - 43
  • [46] Sinus node dysfunction after surgical atrial fibrillation ablation with concomitant mitral valve surgery: Determinants and clinical outcomes
    Kim, Darae
    Shim, Chi Young
    Hong, Geu-Ru
    Cho, In Jeong
    Lee, Seung Hyun
    Chang, Hyuk-Jae
    Lee, Sak
    Ha, Jong-Won
    Chang, Byung-Chul
    PLOS ONE, 2018, 13 (09):
  • [47] Total atrial conduction time as a possible predictor of atrial fibrillation recurrence after catheter ablation for paroxysmal atrial fibrillation: relationship between electrical atrial remodeling and structural atrial remodeling time courses
    Ryuichi Maenosono
    Naoko Mizukami
    Hitoshi Ichiki
    Naoya Oketani
    Fuminori Namino
    Izumi Masamoto
    Toshinori Yuasa
    Munekazu Yamakuchi
    Mitsuru Ohishi
    Teruto Hashiguchi
    Journal of Medical Ultrasonics, 2021, 48 : 295 - 306
  • [48] Longterm Follow-Up After Surgical Ablation Therapy for Atrial Fibrillation Using an Implantable Cardiac Rhythm Monitoring Device
    Kowert, Anke
    Reichart, Bruno
    Juchem, Gerd
    CIRCULATION, 2013, 128 (22)
  • [49] Meta-analysis of the correlation between recurrence of atrial fibrillation and serum uric acid level after radiofrequency ablation
    Chen, Yuan
    Wu, Yucheng
    Chu, Xin
    Wang, Meixiang
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (12): : 8793 - 8799
  • [50] Assessment of the relationship between semaphorin4D level and recurrence after catheter ablation in paroxysmal atrial fibrillation
    Can, Veysi
    Cakmak, Huseyin Altug
    Vatansever, Fahriye
    Kanat, Selcuk
    Ekizler, Firdevs Aysenur
    Huysal, Kagan
    Demir, Mehmet
    BIOMARKERS, 2021, 26 (05) : 468 - 476