Therapeutic monitoring of amiodarone and desethylamiodarone after surgical ablation of atrial fibrillation-evaluation of the relationship between clinical effect and the serum concentration

被引:1
|
作者
Hrudikova, Erika [1 ,2 ]
Grundmann, Milan [1 ]
Kolek, Martin [3 ,4 ]
Urinovska, Romana [1 ,2 ]
Kacirova, Ivana [1 ,2 ]
机构
[1] Univ Ostrava, Fac Med, Dept Clin Pharmacol, Syllabova 19, Ostrava 70300, Czech Republic
[2] Univ Hosp Ostrava, Dept Clin Pharmacol, Dept Lab Med, 17 Listopadu 1790, Ostrava 70852, Czech Republic
[3] Univ Ostrava, Fac Med, Dept Clin Subjects, Syllabova 19, Ostrava 70300, Czech Republic
[4] Univ Hosp Ostrava, Dept Cardiac Surg, 17 Listopadu 1790, Ostrava 70852, Czech Republic
关键词
Amiodarone; Atrial fibrillation; Desethylamiodarone; Maze procedure; Serum concentration; Sinus rhythm; EXPERT CONSENSUS STATEMENT; EFFICACY; SUPPRESSION; MANAGEMENT; CATHETER; PLASMA;
D O I
10.1016/j.jsps.2021.03.004
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Association between clinical effect and serum concentration of amiodarone (AMI) and its active metabolite desethylamidarone (DEA) in patients after surgical ablation (SA) of atrial fibrillation (AF) has not yet been studied. Aims: We wanted to find a correlation between AMI and DEA serum concentration and maintaining sinus rhythm (SR) after SA of AF. Methods: Sixty eight patients with AF who had undergone surgical ablation between 2014 and 2017 were included in a single-centre, prospective, observational study. Maintaining of SR was evaluated by standard 12-lead ECG and 24-hour Holter ECG monitoring at months 1, 3, 6 and 12 following surgery. Therapeutic monitoring of AMI and DEA concentrations was done to optimize therapy and adverse effects were followed up. Results: We have noticed a high success rate in maintaining of SR (overall 83%). The median of serum concentration of AMI was 0.81 mg/L (range 0.16-2.35 mg/L) and DEA 0.70 mg/l (range 0.19-2.63 mg/L). No significant differences were found in the serum concentratration of AMI, DEA or DEA/AMI concentratration ratios between patients with SR and persistent supraventricular tachyarrhythmia except on the second outpatient visit. We observed significant correlation between serum concentration of DEA and thyroid-stimulating hormone elevation. Conclusion: We confirmed the efficacy of AMI and DEA at the measured serum concentrations. However, analysis of these concentrations alone cannot replace assessment of the clinical response for treatment. Establishment of individual AMI (and DEA) concentrations at which the optimal therapeutic response is achieved seems to be advantageous. Therapeutic monitoring of AMI and DEA is helpful in personalised pharmacotherapy after SA of AF. (c) 2021 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:369 / 376
页数:8
相关论文
共 50 条
  • [21] Relationship Between Complex Fractionated Atrial Electrograms During Atrial Fibrillation and the Critical Site of Atrial Tachycardia That Develops After Catheter Ablation for Atrial Fibrillation
    Ban, Ji-Eun
    Chen, Yung-Lung
    Park, Hwan-Cheol
    Lee, Hyun-Soo
    Lee, Dae-In
    Choi, Jong-Il
    Lim, Hong-Euy
    Park, Sang-Weon
    Kim, Young-Hoon
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (02) : 146 - 153
  • [22] The relationship between serum indoxyl sulfate and the renal function after catheter ablation of atrial fibrillation in patients with mild renal dysfunction
    Koike, Hideki
    Morita, Toshisuke
    Tatebe, Junko
    Watanabe, Ippei
    Koike, Makiko
    Yao, Shintaro
    Shinohara, Masaya
    Yuzawa, Hitomi
    Suzuki, Takeya
    Fujino, Tadashi
    Ikeda, Takanori
    HEART AND VESSELS, 2019, 34 (04) : 641 - 649
  • [23] The relationship between serum indoxyl sulfate and the renal function after catheter ablation of atrial fibrillation in patients with mild renal dysfunction
    Hideki Koike
    Toshisuke Morita
    Junko Tatebe
    Ippei Watanabe
    Makiko Koike
    Shintaro Yao
    Masaya Shinohara
    Hitomi Yuzawa
    Takeya Suzuki
    Tadashi Fujino
    Takanori Ikeda
    Heart and Vessels, 2019, 34 : 641 - 649
  • [24] Association between the preprocedural serum potassium level and atrial fibrillation recurrence after catheter ablation
    Yang, Zejun
    Wang, Jue
    Jiang, Chao
    Guo, Hang
    Li, Mingxiao
    Zhao, Zixu
    Zhao, Manlin
    Li, Sitong
    Lai, Yiwei
    He, Liu
    Guo, Xueyuan
    Li, Songnan
    Liu, Nian
    Jiang, Chenxi
    Tang, Ribo
    Long, Deyong
    Du, Xin
    Sang, Caihua
    Dong, Jianzeng
    Ma, Changsheng
    HEART RHYTHM, 2024, 21 (12) : 2429 - 2436
  • [25] Relationship Between Sex and the Effects of Left Atrial Volume Index on Risk of Atrial Fibrillation Recurrence After Ablation
    Lee, Kevin
    Minga, Iva
    Varley, Allyson
    Thorne, Christopher
    Osorio, Jose
    Singleton, Matthew J.
    Silverstein, Joshua
    Metzl, Mark
    CIRCULATION, 2023, 148
  • [26] Relationship Between Early and Late Recurrences After Catheter Ablation for Atrial Tachycardia in Patients With a History of Atrial Fibrillation
    Kahle, Ann-Kathrin
    Jungen, Christiane
    Scherschel, Katharina
    Alken, Fares-Alexander
    Meyer, Christian
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (06) : E010727
  • [27] Association between left atrial low-voltage area, serum apoptosis, and fibrosis biomarkers and incidence of silent cerebral events after catheter ablation of atrial fibrillation
    Mueller, Patrick
    Maier, Johannes
    Dietrich, Johannes-Wolfgang
    Barth, Sebastian
    Griese, Daniel P.
    Schiedat, Fabian
    Szoelloesi, Attila
    Halbfass, Philipp
    Nentwich, Karin
    Roos, Markus
    Krug, Joachim
    Schade, Anja
    Schmitt, Rainer
    Muegge, Andreas
    Deneke, Thomas
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 44 (01) : 55 - 62
  • [28] Total atrial conduction time as a possible predictor of atrial fibrillation recurrence after catheter ablation for paroxysmal atrial fibrillation: relationship between electrical atrial remodeling and structural atrial remodeling time courses
    Maenosono, Ryuichi
    Mizukami, Naoko
    Ichiki, Hitoshi
    Oketani, Naoya
    Namino, Fuminori
    Masamoto, Izumi
    Yuasa, Toshinori
    Yamakuchi, Munekazu
    Ohishi, Mitsuru
    Hashiguchi, Teruto
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (03) : 295 - 306
  • [29] Relationship between Holter findings immediately after ablation of typical atrial flutter and subsequent risk of atrial fibrillation
    Moubarak, Ghassan
    Pavin, Dominique
    Behar, Nathalie
    Martins, Raphael Pedro
    Bouleti, Claire
    Leclercq, Christophe
    Daubert, Jean-Claude
    Mabo, Philippe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (02) : 271 - 272
  • [30] Quantitative Magnetic Resonance Imaging Analysis of the Relationship Between Contact Force and Left Atrial Scar Formation After Catheter Ablation of Atrial Fibrillation
    Sohns, Christian
    Karim, Rashed
    Harrison, James
    Arujuna, Aruna
    Linton, Nick
    Sennett, Richard
    Lambert, Hendrik
    Leo, Giovanni
    Williams, Steven
    Razavi, Reza
    Wright, Matt
    Schaeffter, Tobias
    O'Neill, Mark
    Rhode, Kawal
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (02) : 138 - 145