Comparison of EEG measurement of upper limb movement in motor imagery training system

被引:22
作者
Suwannarat, Arpa [1 ]
Pan-ngum, Setha [1 ]
Israsena, Pasin [2 ]
机构
[1] Chulalongkorn Univ, Dept Comp Engn, Fac Engn, Phayathai Rd, Bangkok 10330, Thailand
[2] Natl Elect & Comp Technol Ctr, 112 Thailand Sci Pk,Phahonyothin Rd, Khlong Luang 12120, Pathumthani, Thailand
关键词
Rehabilitation technology; Brain computer interface (BCI); Common spatial pattern (CSP); Motor imagery (MI); BRAIN-COMPUTER INTERFACES; SINGLE-TRIAL EEG; SPATIAL FILTERS; STROKE PATIENTS; BCI; REHABILITATION; CLASSIFICATION; RECOVERY; DESYNCHRONIZATION; ALGORITHMS;
D O I
10.1186/s12938-018-0534-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: One of the most promising applications for electroencephalogram (EEG)-based brain computer interface is for stroke rehabilitation. Implemented as a standalone motor imagery (MI) training system or as part of a rehabilitation robotic system, many studies have shown benefits of using them to restore motor control in stroke patients. Hand movements have widely been chosen as MI tasks. Although potentially more challenging to analyze, wrist and forearm movement such as wrist flexion/extension and forearm pronation/supination should also be considered for MI tasks, because these movements are part of the main exercises given to patients in conventional stroke rehabilitation. This paper will evaluate the effectiveness of such movements for MI tasks. Methods: Three hand and wrist movement tasks which were hand opening/closing, wrist flexion/extension and forearm pronation/supination were chosen as motor imagery tasks for both hands. Eleven subjects participated in the experiment. All of them completed hand opening/closing task session. Ten subjects completed two MI task sessions which were hand opening/closing and wrist flexion/extension. Five subjects completed all three MI tasks sessions. Each MI task comprised 8 sessions spanning a 4 weeks period. For classification, feature extraction based on common spatial pattern (CSP) algorithm was used. Two types were implemented, one with conventional CSP (termed WB) and one with an increase number of features achieved by filtering EEG data into five bands (termed FB). Classification was done by linear discriminant analysis (LDA) and support vector machine (SVM). Results: Eight-fold cross validation was applied on EEG data. LDA and SVM gave comparable classification accuracy. FB achieved significantly higher classification accuracy compared to WB. The accuracy of classifying wrist flexion/extension task were higher than that of classifying hand opening/closing task in all subjects. Classifying forearm pronation/supination task achieved higher accuracy than classifying hand opening/closing task in most subjects but achieved lower accuracy than classifying wrist flexion/extension task in all subjects. Significant improvements of classification accuracy were found in nine subjects when considering individual sessions of experiments of all MI tasks. The results of classifying hand opening/closing task and wrist flexion/extension task were comparable to the results of classifying hand opening/closing task and forearm pronation/supination task. Classification accuracy of wrist flexion/extension task and forearm pronation/supination task was lower than those of hand movement tasks and wrist movement tasks. Conclusion: High classification accuracy of the three MI tasks support the possibility of using EEG-based stroke rehabilitation system with these movements. Either LDA or SVM can equally be chosen as a classifier since the difference of their accuracies is not statistically significant. Significantly higher classification accuracy made FB more suitable for classifying MI task compared to WB. More training sessions could potentially lead to better accuracy as evident in most subjects in this experiment.
引用
收藏
页数:22
相关论文
共 62 条
  • [1] A Randomized Controlled Trial of EEG-Based Motor Imagery Brain-Computer Interface Robotic Rehabilitation for Stroke
    Ang, Kai Keng
    Chua, Karen Sui Geok
    Phua, Kok Soon
    Wang, Chuanchu
    Chin, Zheng Yang
    Kuah, Christopher Wee Keong
    Low, Wilson
    Guan, Cuntai
    [J]. CLINICAL EEG AND NEUROSCIENCE, 2015, 46 (04) : 310 - 320
  • [2] Ang Kai Keng, 2014, Front Neuroeng, V7, P30, DOI 10.3389/fneng.2014.00030
  • [3] A Large Clinical Study on the Ability of Stroke Patients to Use an EEG-Based Motor Imagery Brain-Computer Interface
    Ang, Kai Keng
    Guan, Cuntai
    Chua, Karen Sui Geok
    Ang, Beng Ti
    Kuah, Christopher Wee Keong
    Wang, Chuanchu
    Phua, Kok Soon
    Chin, Zheng Yang
    Zhang, Haihong
    [J]. CLINICAL EEG AND NEUROSCIENCE, 2011, 42 (04) : 253 - 258
  • [4] Ang KK, 2008, IEEE IJCNN, P2390, DOI 10.1109/IJCNN.2008.4634130
  • [5] A clinical evaluation of non-invasive motor imagery-based brain-computer interface in stroke
    Ang, Kai Keng
    Guan, Cuntai
    Chua, Karen Sui Geok
    Ang, Beng Ti
    Kuah, Christopher Wee Keong
    Wang, Chuanchu
    Phua, Kok Soon
    Chin, Zheng Yang
    Zhang, Haihong
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4178 - +
  • [6] [Anonymous], SIMPLE SOLUTIONS POO
  • [7] [Anonymous], IM OF HANDS
  • [8] [Anonymous], FRONT NEUROSCI SWITZ
  • [9] [Anonymous], 1991, J CLIN NEUROPHYSIOL, DOI DOI 10.1097/00004691-199104000-00007
  • [10] [Anonymous], SPECS AND FEATURES