Aortic Leaflet Stresses Are Substantially Lower Using Pulmonary Visceral Pleura Than Pericardial Tissue

被引:3
作者
Chen, Ye [1 ]
Lu, Xiao [1 ]
Luo, Haoxiang [2 ]
Kassab, Ghassan S. [1 ]
机构
[1] Calif Med Innovat Inst, San Diego, CA 92121 USA
[2] Vanderbilt Univ, Dept Mech Engn, Nashville, TN USA
关键词
aortic valve; cardiovascular flow; fluid-structure interaction; leaflet stresses; tissue stiffness; FLUID-STRUCTURE INTERACTION; LARGE DEFORMATIONS; MECHANICAL-STRESS; VALVE DYNAMICS; SIMULATIONS; CALCIFICATION; DISEASE; ROOT;
D O I
10.3389/fbioe.2022.869095
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: Porcine heart and bovine pericardium valves, which are collagen-based with relatively little elastin, have been broadly utilized to construct bioprosthetic heart valves (BHVs). With a larger proportion of elastin, the pulmonary visceral pleura (PVP) has greater elasticity and could potentially serve as an advantageous biomaterial for the construction/repair of BHVs. The question of how the aortic valve's performance is affected by its bending rigidity has not been well studied. Methods: Based on the stress-strain relationships of the pericardium and PVP determined by planar uni-axial tests, a three-dimensional (3D) computational fluid-structure interaction (FSI) framework is employed to numerically investigate the aortic valve's performance by considering three different cases with Young's modulus as follows: E = 375 , 750 , and 1500 kPa, respectively. Results: The stroke volumes are 112, 99.6, and 91.4 ml as Young's modulus increases from 375 to 750 and 1500 kPa, respectively. Peak geometric opening area (GOA) values are 2.3, 2.2, and 2.0 cm(2) for E = 375 , 750, and 1500 kPa, respectively. The maximum value of the aortic leaflet stress is about 271 kPa for E = 375 kPa, and it increases to about 383 and 540 kPa for E = 750 and 1500 kPa in the belly region at the peak systole, while it reduces from 550 kPa to 450 and 400 kPa for E = 375 , 750, and 1500 kPa, respectively, at the instant of peak "water-hammer ". Conclusion: A more compliant PVP aortic leaflet valve with a smaller Young's modulus, E , has a higher cardiac output, larger GOA, and lower hemodynamic resistance. Most importantly, the aortic leaflet stresses are substantially lower in the belly region within the higher compliance PVP aortic valve tissue during the systole phase, even though some stress increase is also found during the fast-closing phase due to the "water-hammer " effect similar to that in the pericardial tissue. Future clinical studies will be conducted to test the hypothesis that the PVP-based valve leaflets with higher compliance will have lower fatigue or calcification rates due to the overall lower stress.
引用
收藏
页数:9
相关论文
共 35 条
[1]   Fluid-structure interaction, immersed boundary-finite element method simulations of bio-prosthetic heart valves [J].
Borazjani, Iman .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2013, 257 :103-116
[2]   Pressure distribution over the leaflets and effect of bending stiffness on fluid-structure interaction of the aortic valve [J].
Chen, Ye ;
Luo, Haoxiang .
JOURNAL OF FLUID MECHANICS, 2020, 883
[3]   A computational study of the three-dimensional fluid-structure interaction of aortic valve [J].
Chen, Ye ;
Luo, Haoxiang .
JOURNAL OF FLUIDS AND STRUCTURES, 2018, 80 :332-349
[4]   On the Mechanics of Transcatheter Aortic Valve Replacement [J].
Dasi, Lakshmi P. ;
Hatoum, Hoda ;
Kheradvar, Arash ;
Zareian, Ramin ;
Alavi, S. Hamed ;
Sun, Wei ;
Martin, Caitlin ;
Thuy Pham ;
Wang, Qian ;
Midha, Prem A. ;
Raghav, Vrishank ;
Yoganathan, Ajit P. .
ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (02) :310-331
[5]   STRUCTURAL-CHANGES IN GLUTARALDEHYDE-TREATED PORCINE HETEROGRAFTS USED AS SUBSTITUTE CARDIAC VALVES - TRANSMISSION AND SCANNING ELECTRON-MICROSCOPIC OBSERVATIONS IN 12 PATIENTS [J].
FERRANS, VJ ;
SPRAY, TL ;
BILLINGHAM, ME ;
ROBERTS, WC .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (07) :1159-1184
[6]   A comparative study of bovine and porcine pericardium to highlight their potential advantages to manufacture percutaneous cardiovascular implants [J].
Gauvin, Robert ;
Marinov, Georgi ;
Mehri, Yayhe ;
Klein, Julianne ;
Li, Bin ;
Larouche, Danielle ;
Guzman, Randolph ;
Zhang, Ze ;
Germain, Lucie ;
Guidoin, Robert .
JOURNAL OF BIOMATERIALS APPLICATIONS, 2013, 28 (04) :552-565
[7]   Image-Guided Fluid-Structure Interaction Simulation of Transvalvular Hemodynamics: Quantifying the Effects of Varying Aortic Valve Leaflet Thickness [J].
Gilmanov, Anvar ;
Barker, Alexander ;
Stolarski, Henryk ;
Sotiropoulos, Fotis .
FLUIDS, 2019, 4 (03)
[8]   Comparative hemodynamics in an aorta with bicuspid and trileaflet valves [J].
Gilmanov, Anvar ;
Sotiropoulos, Fotis .
THEORETICAL AND COMPUTATIONAL FLUID DYNAMICS, 2016, 30 (1-2) :67-85
[9]   A numerical approach for simulating fluid structure interaction of flexible thin shells undergoing arbitrarily large deformations in complex domains [J].
Gilmanov, Anvar ;
Le, Trung Bao ;
Sotiropoulos, Fotis .
JOURNAL OF COMPUTATIONAL PHYSICS, 2015, 300 :814-843
[10]   Immersed boundary model of aortic heart valve dynamics with physiological driving and loading conditions [J].
Griffith, Boyce E. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2012, 28 (03) :317-345