Biomechanical Comparison of Titanium Locking Fragment-Specific and Volar Locking Plates for AO B1 and B2 Fractures of the Distal Radius

被引:1
|
作者
Martin, Dennis P. [1 ]
Park, Andrew G. [1 ]
Jamison, David [2 ]
Jones, Christopher M. [1 ]
Ilyas, Asif M. [1 ]
机构
[1] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Dept Orthoped Surg, Rothman Inst, 125 S 9th St,Suite 1000, Philadelphia, PA 19107 USA
[2] Villanova Univ, Dept Mech Engn, Villanova, PA 19085 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2019年 / 44卷 / 12期
关键词
Distal radius; dorsal shear; fragment-specific; radial styloid; volar locking; LOW-PROFILE DORSAL; DISPLACED FRACTURES; SURGICAL-TREATMENT; FIXATION; PART; COMPLICATIONS; STABILITY; FORCES; SYSTEM; SCREW;
D O I
10.1016/j.jhsa.2019.02.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose This biomechanical study compared the stability of volar locking plates (VLPs) and locking fragment-specific (LFS) dorsal and radial styloid plates for the fixation of dorsal (AO 23-B2) and radial styloid (AO 23-B1) shear fractures of the distal radius, respectively. Methods Two groups of 6 composite radii were fixed with a VLP or an LFS dorsal plate over a simulated dorsal shear fracture. Two additional groups of 6 radii received the same VLP or an LFS radial plate to fix a radial styloid fracture. Each plated radius was tested under cyclic axial compression by a servohydraulic testing machine that recorded axial displacement per cycle. Construct stiffness was calculated from the slope of the force-displacement curve. Results In the dorsal shear fracture model, the dorsal LFS plate exhibited less displacement than the VLP (0.32 +/- 0.04 vs 0.43 +/- 0.07 mm, respectively) and showed greater average stiffness (645 +/- 64 vs 433 +/- 88 N/mm, respectively). Plate type was responsible for 53.1% of the variation in displacement and 68.6% of the variation in stiffness. In the radial styloid fracture model, variations due to number of cycles elapsed and plate type were similar for displacement and stiffness in both groups. The average stiffness during cyclical nondestructive testing was 566 +/- 45 and 573 +/- 60 N/mm for VLP and LFS radial plating groups, respectively. Conclusions For AO 23-B2 (dorsal rim) fractures, the dorsal LFS plates exhibited significantly less displacement and greater stiffness in axial loading than VLPs. ForAO23-B1 (radial styloid) fractures, the VLP displayed similar displacement and stiffness to the radial LFS plates. Copyright (C) 2019 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:1093.e1 / 1093.e8
页数:8
相关论文
共 31 条
  • [21] Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation - a biomechanical study
    Gordon, Katharina
    Winkler, Martin
    Hofstaedter, Thomas
    Dorn, Ulrich
    Augat, Peter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S51 - S57
  • [22] Biomechanical Study on the Cyclic Stability of Distal Radius C2 Type Osteoporotic Fractures Using Locking Plates in a Cadaver Model
    Chih-Kun Hsiao
    Yuan-Kun Tu
    Cheng-Hung Lee
    Cheng-Yo Yen
    Feng-Chen Kao
    Yi-Jung Tsai
    Journal of Medical and Biological Engineering, 2018, 38 : 707 - 714
  • [23] Comparison of open reduction volar locking plate fixation and closed reduction percutaneous K-wire fixation in the treatment of AO type C1 distal radius fractures
    Yetkin, Huseyin
    Altay, Taskin
    Ozan, Firat
    Kayali, Cemil
    Koyuncu, Semmi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (01): : 1139 - 1144
  • [24] A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures
    Switaj, Paul J.
    Fuchs, Daniel
    Alshouli, Mohammed
    Patwardhan, Avinash G.
    Voronov, Leonard I.
    Muriuki, Muturi
    Havey, Robert M.
    Kadakia, Anish R.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
  • [25] Stabilisation of vertical unstable distal clavicular fractures (Neer 2b) using locking T-plates and suture anchors
    Herrmann, S.
    Schmidmaier, G.
    Greiner, S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (03): : 236 - 239
  • [26] Radiographic Parameters to Predict Union After Volar Percutaneous Fixation of Herbert Type B1 and B2 Scaphoid Fractures
    Mahmoud, Mostafa
    Hegazy, Mohamed
    Khaled, Sherif Ahmed
    Abdelatif, Nasef Mohamed Nasef
    Osman, Walid
    Elfar, John C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (02): : 203 - 207
  • [27] Periprosthetic Femoral Fracture - A Biomechanical Comparison Between Vancouver Type B1 and B2 Fixation Methods
    Moazen, Mehran
    Mak, Jonathan H.
    Etchels, Lee W.
    Jin, Zhongmin
    Wilcox, Ruth K.
    Jones, Alison C.
    Tsiridis, Eleftherios
    JOURNAL OF ARTHROPLASTY, 2014, 29 (03) : 495 - 500
  • [28] Comparison of Locking Plate Fixation and Coracoclavicular Ligament Reconstruction for Neer Type 2B Distal Clavicle Fractures
    Kim, Dong Jin
    Lee, Yoon Min
    Yoon, Eun Ji
    Sur, Yoo Joon
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (03)
  • [29] Anterior versus posterior approach in the management of AO Type B1 & B2 traumatic thoracolumbar fractures: A level 1 trauma centre study
    Tan, Terence
    Huang, Milly S.
    Mathew, Joseph
    Fitzgerald, Mark
    Chan, Patrick
    Hunn, Martin K.
    Tee, Jin
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 72 : 219 - 223
  • [30] Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems
    Seuthe, Raphael
    Seekamp, Andreas
    Kurz, Bodo
    Pfarr, Julian
    Schaefer, Jost Philipp
    Peh, Simon
    Lippross, Sebastian
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)