Xenon Ventilation Imaging Using Dual-Energy Computed Tomography in Asthmatics Initial Experience

被引:72
|
作者
Chae, Eun Jin [1 ,2 ]
Seo, Joon Beom [1 ,2 ]
Lee, Jeongjin [3 ]
Kim, Namkug [1 ,2 ]
Goo, Hyun Woo [1 ,2 ]
Lee, Hyun Joo [1 ,2 ]
Lee, Choong Wook [1 ,2 ]
Ra, Seung Won [4 ]
Oh, Yeon-Mok [4 ]
Cho, You Sook [5 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Catholic Univ Korea, Dept Digital Media, Bucheon Si, South Korea
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Pulm & Crit Care Med, Seoul 138736, South Korea
[5] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Allergy & Clin Immunol,Clin Res Ctr Chron Ob, Seoul 138736, South Korea
关键词
xenon; asthma; ventilation; dual-energy CT; HE-3; MAGNETIC-RESONANCE; LOCAL PULMONARY VENTILATION; AIRWAY WALL THICKNESS; HALF-MAXIMUM METHOD; SEMIAUTOMATIC MEASUREMENT; MEASUREMENT ACCURACY; FLOW OBSTRUCTION; CT; LUNG; METHACHOLINE;
D O I
10.1097/RLI.0b013e3181dfdae0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of xenon ventilation computed tomography (CT) for evaluating ventilation abnormality in asthmatics. Materials and Methods: Twenty-two, stable asthmatics (M: F = 10: 12; mean age, 57.6) were included. Single-phase, whole-thorax, dual-energy CT was performed using dual-source CT (Somatom Definition, Siemens) after subjects had inhaled 30% xenon for 90 seconds. Parameters include 512 x 512 matrix; 14 x 1.2 mm collimation; 40/140 eff. mAs at 140/80 kV; 0.45 pitch; and 0.33 seconds rotation time. On the color-coded xenon map, the extent of the ventilation defect was visually assessed using a 5-point scale in each lobe (0, absent defect; 1, 0%-25%; 2, 25%-50%; 3, 50%-75%; and 4, 75%-100%), which was defined as defect score. On the weighted average image, airway wall dimensions were measured at 4 segmental bronchi in both upper and lower lobes. Patients were classified into a defect group and a defect-free group based on the presence of defects shown on the xenon map. Pulmonary function test parameters and airway wall dimensions were compared in those 2 groups. Correlation analyses between the defect score, pulmonary function test, and airway wall dimensions were performed. Results: Sixteen asthmatics showed peripheral ventilation defects on the xenon map (defect score, 6.6 +/- 4.2). The defect group had a significantly lower forced expiratory volume in 1 second (FEV1) and thicker airway wall than that of the defect-free group (P = 0.04 and 0.02, respectively). The defect score correlated negatively with a ratio of FEV1 and forced vital capacity (FEV1/FVC) (r =-0.44, P = 0.04) and corrected diffusing capacity (r =-0.76, P = 0.04) and correlated positively with total lung capacity, functional residual volume, and residual volume (r = 0.90, P < 0.005; r = 0.99, P < 0.001; r = 0.88, P = 0.008, respectively). Conclusions: The ventilation defects appeared on xenon ventilation CT in asthmatics with more severe airflow limitation and airway wall thickening. The extent of the ventilation defects showed correlations with parameters of pulmonary function test.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [1] Initial experience with visualizing hand and foot tendons by dual-energy computed tomography
    Deng, Kai
    Sun, Cong
    Liu, Cheng
    Ma, Rui
    CLINICAL IMAGING, 2009, 33 (05) : 384 - 389
  • [2] Dual-Energy Computed Tomography in Genitourinary Imaging
    Mileto, Achille
    Marin, Daniele
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2017, 55 (02) : 373 - +
  • [3] Xenon-Enhanced Dual-Energy CT Lung Ventilation Imaging: Techniques and Clinical Applications
    Kong, Xiang
    Sheng, Hui Xue
    Lu, Guang Ming
    Meinel, Felix G.
    Dyer, Kevin T.
    Schoepf, U. Joseph
    Zhang, Long Jiang
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (02) : 309 - 317
  • [4] Imaging of nanoparticles with dual-energy computed tomography
    Ducote, J. L.
    Alivov, Y.
    Molloi, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07): : 2031 - 2044
  • [5] Assessment of regional emphysema, air-trapping and Xenon-ventilation using dual-energy computed tomography in chronic obstructive pulmonary disease patients
    Lee, Sang Min
    Seo, Joon Beom
    Hwang, Hye Jeon
    Kim, Namkug
    Oh, Sang Young
    Lee, Jae Seung
    Lee, Sei Won
    Oh, Yeon-Mok
    Kim, Tae Hoon
    EUROPEAN RADIOLOGY, 2017, 27 (07) : 2818 - 2827
  • [6] Assessment of regional emphysema, air-trapping and Xenon-ventilation using dual-energy computed tomography in chronic obstructive pulmonary disease patients
    Sang Min Lee
    Joon Beom Seo
    Hye Jeon Hwang
    Namkug Kim
    Sang Young Oh
    Jae Seung Lee
    Sei Won Lee
    Yeon-Mok Oh
    Tae Hoon Kim
    European Radiology, 2017, 27 : 2818 - 2827
  • [7] Dual-Energy Computed Tomography in Cardiothoracic Vascular Imaging
    De Santis, Domenico
    Eid, Marwen
    De Cecco, Carlo N.
    Jacobs, Brian E.
    Albrecht, Moritz H.
    Varga-Szemes, Akos
    Tesche, Christian
    Caruso, Damiano
    Laghi, Andrea
    Schoepf, Uwe Joseph
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 521 - +
  • [8] Application of Dual-Energy Spectral Computed Tomography to Thoracic Oncology Imaging
    Kim, Cherry
    Kim, Wooil
    Park, Sung-Joon
    Lee, Young Hen
    Hwang, Sung Ho
    Yong, Hwan Seok
    Oh, Yu-Whan
    Kang, Eun-Young
    Lee, Ki Yeol
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (07) : 838 - 850
  • [9] Assessment of Regional Xenon Ventilation, Perfusion, and Ventilation-Perfusion Mismatch Using Dual-Energy Computed Tomography in Chronic Obstructive Pulmonary Disease Patients
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Sang Min
    Kim, Namkug
    Oh, Sang Young
    Lee, Jae Seung
    Lee, Sei Won
    Oh, Yeon-Mok
    INVESTIGATIVE RADIOLOGY, 2016, 51 (05) : 306 - 315
  • [10] Pulmonary ventilation and perfusion imaging with dual-energy CT
    Thieme, Sven F.
    Hoegl, Sandra
    Nikolaou, Konstantin
    Fisahn, Juergen
    Irlbeck, Michael
    Maxien, Daniel
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2010, 20 (12) : 2882 - 2889