Energy layer optimization via energy matrix regularization for proton spot-scanning arc therapy

被引:26
|
作者
Zhang, Gezhi [1 ]
Shen, Haozheng [1 ]
Lin, Yuting [2 ]
Chen, Ronald C. [2 ]
Long, Yong [1 ]
Gao, Hao [2 ]
机构
[1] Shanghai Jiao Tong Univ, Univ Michigan Shanghai Jiao Tong Univ Joint Inst, Shanghai, Peoples R China
[2] Univ Kansas, Med Ctr, Dept Radiat Oncol, Kansas City, MO USA
关键词
energy layer optimization; IMPT; SPArc; DELIVERY-EFFICIENT; SPARC THERAPY; ALGORITHM; ROBUST; HEAD;
D O I
10.1002/mp.15836
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Spot-scanning arc therapy (SPArc) is an emerging proton modality that can potentially offer a combination of advantages in plan quality and delivery efficiency, compared with traditional IMPT of a few beam angles. Unlike IMPT, frequent low-to-high energy layer switching (so called switch-up (SU)) can degrade delivery efficiency for SPArc. However, it is a tradeoff between the minimization of SU times and the optimization of plan quality. This work will consider the energy layer optimization (ELO) problem for SPArc and develop a new ELO method via energy matrix (EM) regularization to improve plan quality and delivery efficiency. Methods The major innovation of EM method for ELO is to design an EM that encourages desirable energy-layer map with minimal SU during SPArc, and then incorporate this EM into the SPArc treatment planning to simultaneously minimize the number of SU and optimize plan quality. The EM method is solved by the fast iterative shrinkage-thresholding algorithm and validated in comparison with a state-of-the-art method, so-called energy sequencing (ES). Results EM is validated and compared with ES using representative clinical cases. In terms of delivery efficiency, EM had fewer SU than ES with an average of 35% reduction of SU. In terms of plan quality, compared with ES, EM had smaller optimization objective values and better target dose conformality, and generally lower dose to organs-at-risk and lower integral dose to body. In terms of computational efficiency, EM was substantially more efficient than ES by at least 10-fold. Conclusion We have developed a new ELO method for SPArc using EM regularization and shown that this new method EM can improve both delivery efficiency and plan quality, with substantially reduced computational time, compared with ES.
引用
收藏
页码:5752 / 5762
页数:11
相关论文
共 46 条
  • [41] Reply to Comment on 'Linear energy transfer incorporated intensity modulated proton therapy optimization'
    Cao, Wenhua
    Khabazian, Azin
    Yepes, Pablo
    Lim, Gino
    Poenisch, Falk
    Grosshans, David
    Mohan, Radhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (05)
  • [42] Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors
    Gu, Wenbo
    O'Connor, Daniel
    Dan Nguyen
    Yu, Victoria Y.
    Ruan, Dan
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2018, 45 (04) : 1338 - 1350
  • [43] Linear energy transfer weighted beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2021, 48 (01) : 57 - 70
  • [44] Investigate potential clinical benefits and linear energy transfer sparing utilizing proton arc therapy for hepatocellular carcinoma
    Liu, Peilin
    Cao, Xi
    Dalfsen, Raymond
    Soukup, Martin
    Dolan, James
    Zhao, Lewei
    Wang, Zishen
    Mulhem, Anthony
    Gao, Xian-shu
    Liu, Gang
    Cong, Xiaoda
    Stevens, Craig
    Deroniyagala, Rohan
    Li, Xiaoqiang
    Ding, Xuanfeng
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 126
  • [45] Study of linear energy transfer effect on rib fracture in breast cancer patients receiving pencil-beam-scanning proton therapy
    Yang, Yunze
    Gergelis, Kimberly R.
    Shen, Jiajian
    Afzal, Arslan
    Mullikin, Trey C.
    Gao, Robert W.
    Aziz, Khaled
    Shumway, Dean A.
    Corbin, Kimberly S.
    Liu, Wei
    Mutter, Robert W.
    MEDICAL PHYSICS, 2025,
  • [46] Exploratory study of seed spots analysis to characterize dose and linear-energy-transfer effect in adverse event initialization of pencil-beam-scanning proton therapy
    Yang, Yunze
    Patel, Samir H.
    Bridhikitti, Jidapa
    Wong, William W.
    Halyard, Michele Y.
    McGee, Lisa A.
    Rwigema, Jean-Claude M.
    Schild, Steven E.
    Vora, Sujay A.
    Liu, Tianming
    Bues, Martin
    Fatyga, Mirek
    Foote, Robert L.
    Liu, Wei
    MEDICAL PHYSICS, 2022, 49 (09) : 6237 - 6252