Radiosensitivity of children: potential for overexposure in CR and DR and magnitude of doses in ordinary radiographic examinations

被引:63
作者
Don, S [1 ]
机构
[1] Washington Univ, St Louis Childrens Hosp, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63112 USA
关键词
radiation dose; computed radiography; digital radiography; ALARA; pediatrics;
D O I
10.1007/s00247-004-1266-9
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The linear, no-threshold model is currently the best estimate of risk from radiation exposure with no level below which radiation is safe. Plain-film radiography has a much lower patient dose than CT or fluoroscopy. With the advent of computed radiography (CR) the dose to patients is higher than screen-film radiography and overexposure is quite common. Task-oriented adjustment of technique, commonly used in CT, is rarely used in CR. Exposure reduction is important in CR as research indicates an increased risk of childhood acute lymphocytic leukemia from plain-film studies and an increased risk of fatal breast cancer from scoliosis series. Future needs include better documentation of the dose the patient receives, dose-based research on the radiation risk, and accreditation in CR and digital radiography for public assurance.
引用
收藏
页码:S167 / S172
页数:6
相关论文
共 29 条
[1]  
Beir V., 1990, HLTH EFFECTS EXPOSUR, DOI DOI 10.17226/1224
[2]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[3]   Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging [J].
Brown, PH ;
Thomas, RD ;
Silberberg, PJ ;
Johnson, LM .
PEDIATRIC RADIOLOGY, 2000, 30 (04) :229-235
[4]   A multihospital survey of radiation exposure and image quality in pediatric fluoroscopy [J].
Brown, PH ;
Silberberg, PJ ;
Thomas, RD ;
Strife, JL ;
Towbin, RB .
PEDIATRIC RADIOLOGY, 2000, 30 (04) :236-242
[5]   Review - Cancer risk from low-level radiation [J].
Cohen, BL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1137-1143
[6]   SOFT-COPY COMPUTED RADIOGRAPHY IN NEONATAL AND PEDIATRIC INTENSIVE-CARE UNITS - COST-SAVINGS ANALYSIS [J].
DON, S ;
ALBERTINA, MJ ;
AMMANN, DL ;
EVENS, RG ;
SIEGEL, MJ .
RADIOLOGY, 1995, 197 (02) :501-505
[7]   Computed radiography versus screen-film radiography: Detection of pulmonary edema in a rabbit model that simulates neonatal pulmonary infiltrates [J].
Don, S ;
Hildebolt, CF ;
Sharp, TL ;
Shackelford, GD ;
Lau, DM ;
Herman, TE ;
McAlister, WH .
RADIOLOGY, 1999, 213 (02) :455-460
[8]  
DON S, 2002, OVEREXPOSURE CHILDRE
[9]  
DON S, 2000, STUDY EXPOSURE REDUC
[10]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306