Exergy Analysis of Liquid Desiccant Dehumidification System

被引:14
作者
Xiong, Z. Q. [1 ]
Dai, Y. J. [1 ]
Wang, R. Z. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Solar Energy Res Ctr, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
Exergy analysis; Liquid desiccant; Dehumidification; Adjustable concentration; MASS-TRANSFER; AIR;
D O I
10.1080/15435071003795881
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid desiccant dehumidification system has been recognized as an efficient independent humidity control HVAC system. To provide a thorough understanding of the liquid-desiccant-based system and improve its performance, analysis using the second thermodynamic law is carried out. Exergy performances of the dehumidifier and the regenerator are first studied to find out the proper ranges for the important operating parameters such as the desiccant concentration, air humidity ratio, flow rate ratio of desiccant to air, and regeneration temperature. Exergy analysis of the basic liquid desiccant dehumidification system is carried out with appropriate parameters. Exergy efficiency of the basic system is only 6.3%. It is found that desiccant-desiccant heat exchanger (HE), hot-water-desiccant HE, and cooling-water-desiccant HE contributes to 75.9% of the entire exergy loss because of the high temperature difference between the hot regenerated liquid desiccant and the warm diluted liquid desiccant, and the incomplete heat recovery. Furthermore, to improve the system performance, adjustable liquid desiccant concentration method and calcium chloride (CaCl2) predehumidification method are proposed. The system exergy efficiency can be improved by using these two methods to 19.1% and 21.9% respectively. Useful energy storage capacity is increased by adjustable liquid desiccant concentration method, besides the less exergy losses in heat recovery between hot regenerated desiccant solution and warm dilute desiccant solution. The CaCl2 predehumidification method significantly reduces the irreversibility in the dehumidifier by using a pre-dehumidification process by CaCl2 solution before the dehumidification process by lithium chloride solution.
引用
收藏
页码:241 / 262
页数:22
相关论文
共 15 条
[1]   Exergy analysis of a liquid-desiccant-based, hybrid air-conditioning system [J].
Ahmed, CSK ;
Gandhidasan, P ;
Zubair, SM ;
Al-Farayedhi, AA .
ENERGY, 1998, 23 (01) :51-59
[2]   Comparative study between parallel and counter flow configurations between air and falling film desiccant in the presence of nanoparticle suspensions [J].
Ali, A ;
Vafai, K ;
Khaled, ARA .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (08) :725-745
[3]  
*AM SOC HEAT REFR, 2003, ASHRAEHANDBOOK HVAC
[4]  
Assouad YT, 1985, THESIS ILLINOIS I TE
[5]  
BEJAN A, 1997, THERMODYNAMIC ENG TH
[6]   Numerical simulation and theoretical analysis of heat and mass transfer in a cross flow liquid desiccant air dehumidifier packed with honeycomb paper [J].
Dai, YJ ;
Zhang, HF .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) :1343-1356
[7]   Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning [J].
Dai, YJ ;
Wang, RZ ;
Zhang, HF ;
Yu, JD .
APPLIED THERMAL ENGINEERING, 2001, 21 (12) :1185-1202
[8]   Study of an aqueous lithium chloride desiccant system: Air dehumidification and desiccant regeneration [J].
Fumo, N ;
Goswami, DY .
SOLAR ENERGY, 2002, 72 (04) :351-361
[9]   Performance analysis of liquid desiccant dehumidification systems [J].
Jain, Sanjeev ;
Bansal, P. K. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (05) :861-872
[10]   New type of fresh air processor with liquid desiccant total heat recovery [J].
Li, Z ;
Liu, XH ;
Jiang, Y ;
Chen, XY .
ENERGY AND BUILDINGS, 2005, 37 (06) :587-593