Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk

被引:75
作者
Chivukula, Venkat Keshav [2 ]
Beckman, Jennifer A. [1 ]
Prisco, Anthony R. [4 ]
Dardas, Todd [1 ]
Lin, Shin [1 ]
Smith, Jason W. [3 ]
Mokadam, Nahush A. [3 ]
Aliseda, Alberto [2 ]
Mahr, Claudius [1 ]
机构
[1] Univ Washington, Div Cardiol, 1959 NE Pacific St, Seattle, WA 98195 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] Univ Washington, Div Cardiothorac Surg, Seattle, WA 98195 USA
[4] Univ Minnesota, Dept Med, Box 736 UMHC, Minneapolis, MN 55455 USA
关键词
cannula; heart assist devices; heart ventricles; stroke; thrombosis; CONTINUOUS-FLOW; PUMP; MANAGEMENT; TRANSPLANT; THERAPY; SYSTEM; BRIDGE;
D O I
10.1161/CIRCHEARTFAILURE.117.004325
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: As heart failure prevalence continues to increase in the setting of a static donor supply, left ventricular assist device (LVAD) therapy for end-stage heart failure continues to grow. Anecdotal evidence suggests that malalignment of the LVAD inflow cannula may increase thrombosis risk, but this effect has not been explored mechanistically or quantified statistically. Our objective is to elucidate the impact of surgical angulation of the inflow cannula on thrombogenicity. METHODS AND RESULTS: Unsteady computational fluid dynamics is used in conjunction with computational modeling and virtual surgery to model flow through the left ventricle for 5 different inflow cannula angulations. We use a holistic approach to evaluate thrombogenicity: platelet-based (Lagrangian) metrics to evaluate the platelet mechanical environment, combined with flow-based (Eulerian) metrics to investigate intraventricular hemodynamics. The thrombogenic potential of each LVAD inflow cannula angulation is quantitatively evaluated based on platelet shear stress history and residence time. Intraventricular hemodynamics are strongly influenced by LVAD inflow cannula angulation. Platelet behavior indicates elevated thrombogenic potential for certain inflow cannula angles, potentially leading to platelet activation. Our analysis demonstrates that the optimal range of inflow angulation is within 0 +/- 7 degrees of the left ventricular apical axis. CONCLUSIONS: Angulation of the inflow cannula >7 degrees from the apical axis (axis connecting mitral valve and ventricular apex) leads to markedly unfavorable hemodynamics as determined by computational fluid dynamics. Computational hemodynamic simulations incorporating Lagrangian and Eulerian metrics are a powerful tool for studying optimization of LVAD implantation strategies, with the long-term potential of improving outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Use of Sealed Grafts in the HeartMate II Left Ventricular Assist Device Inflow and Outflow Conduits
    Gregoric, Igor D.
    Radovancevic, Rajko
    Patel, Manish
    Fenik, Yelena
    Cohn, William E.
    Frazier, O. H.
    ASAIO JOURNAL, 2014, 60 (03) : 300 - 303
  • [42] Evaluation of aspirin platelet inhibition in left ventricular assist device population
    Morgan, Eva P.
    Hawn, Jaclyn M.
    Meadows, Holly
    Houston, Brian
    Tedford, Ryan J.
    Fajardo, Johana
    Perez, Caroline
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (12) : 4503 - 4508
  • [43] Medical Management of Patients With a Left Ventricular Assist Device for the Non-Left Ventricular Assist Device Specialist
    DeVore, Adam D.
    Patel, Priyesh A.
    Patel, Chetan B.
    JACC-HEART FAILURE, 2017, 5 (09) : 621 - 631
  • [44] Initial Experience of Conversion of Toyobo Paracorporeal Left Ventricular Assist Device to DuraHeart Left Ventricular Assist Device
    Yoshioka, Daisuke
    Sakaguchi, Taichi
    Saito, Shunsuke
    Miyagawa, Shigeru
    Nishi, Hiroyuki
    Yoshikawa, Yasushi
    Fukushima, Satsuki
    Ueno, Takayoshi
    Kuratani, Toru
    Sawa, Yoshiki
    CIRCULATION JOURNAL, 2012, 76 (02) : 372 - 376
  • [45] Endovascular repair of ventricular assist device outflow cannula stenosis
    Ahmad, Faraz S.
    Sauer, Andrew J.
    Ricciardi, Mark J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (07) : E81 - E85
  • [46] Management of Pump Thrombosis in Patients with Left Ventricular Assist Devices
    Stulak, John M.
    Sharma, Shashank
    Maltais, Simon
    AMERICAN JOURNAL OF CARDIOVASCULAR DRUGS, 2015, 15 (02) : 89 - 94
  • [47] HeartWare Left Ventricular Assist Device Pump Thrombosis A Shift Away From Ramp
    Rame, J. Eduardo
    Birati, Edo Y.
    JACC-HEART FAILURE, 2015, 3 (11) : 857 - 859
  • [48] Eptifibatide for the Treatment of HeartMate II Left Ventricular Assist Device Thrombosis
    Al-Quthami, Adeeb H.
    Jumean, Marwan
    Kociol, Robb
    Duc Thinh Pham
    Kiernan, Michael
    DeNofrio, David
    Kapur, Navin K.
    CIRCULATION-HEART FAILURE, 2012, 5 (04) : E68 - E70
  • [49] Ascending aorta thrombosis in a HeartWare® left ventricular assist device recipient
    Saplacan, Vladimir
    Caprio, Sabino
    Belin, Annette
    Buklas, Dimitrios
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (01) : E27 - E27
  • [50] Role of thromboelastography in predicting and defining pump thrombosis in left ventricular assist device patients
    Xia, Ranran
    Varnado, Sara
    Graviss, Edward A.
    Nguyen, Duc T.
    Cruz-Solbes, Ana
    Guha, Ashrith
    Krisl, Jill C.
    THROMBOSIS RESEARCH, 2020, 192 : 29 - 35