Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk

被引:75
|
作者
Chivukula, Venkat Keshav [2 ]
Beckman, Jennifer A. [1 ]
Prisco, Anthony R. [4 ]
Dardas, Todd [1 ]
Lin, Shin [1 ]
Smith, Jason W. [3 ]
Mokadam, Nahush A. [3 ]
Aliseda, Alberto [2 ]
Mahr, Claudius [1 ]
机构
[1] Univ Washington, Div Cardiol, 1959 NE Pacific St, Seattle, WA 98195 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] Univ Washington, Div Cardiothorac Surg, Seattle, WA 98195 USA
[4] Univ Minnesota, Dept Med, Box 736 UMHC, Minneapolis, MN 55455 USA
关键词
cannula; heart assist devices; heart ventricles; stroke; thrombosis; CONTINUOUS-FLOW; PUMP; MANAGEMENT; TRANSPLANT; THERAPY; SYSTEM; BRIDGE;
D O I
10.1161/CIRCHEARTFAILURE.117.004325
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: As heart failure prevalence continues to increase in the setting of a static donor supply, left ventricular assist device (LVAD) therapy for end-stage heart failure continues to grow. Anecdotal evidence suggests that malalignment of the LVAD inflow cannula may increase thrombosis risk, but this effect has not been explored mechanistically or quantified statistically. Our objective is to elucidate the impact of surgical angulation of the inflow cannula on thrombogenicity. METHODS AND RESULTS: Unsteady computational fluid dynamics is used in conjunction with computational modeling and virtual surgery to model flow through the left ventricle for 5 different inflow cannula angulations. We use a holistic approach to evaluate thrombogenicity: platelet-based (Lagrangian) metrics to evaluate the platelet mechanical environment, combined with flow-based (Eulerian) metrics to investigate intraventricular hemodynamics. The thrombogenic potential of each LVAD inflow cannula angulation is quantitatively evaluated based on platelet shear stress history and residence time. Intraventricular hemodynamics are strongly influenced by LVAD inflow cannula angulation. Platelet behavior indicates elevated thrombogenic potential for certain inflow cannula angles, potentially leading to platelet activation. Our analysis demonstrates that the optimal range of inflow angulation is within 0 +/- 7 degrees of the left ventricular apical axis. CONCLUSIONS: Angulation of the inflow cannula >7 degrees from the apical axis (axis connecting mitral valve and ventricular apex) leads to markedly unfavorable hemodynamics as determined by computational fluid dynamics. Computational hemodynamic simulations incorporating Lagrangian and Eulerian metrics are a powerful tool for studying optimization of LVAD implantation strategies, with the long-term potential of improving outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Presentation and management of left ventricular assist device inflow cannula malposition
    Milano, Carmelo A.
    Simeone, Alan A.
    Blue, Laura J.
    Rogers, Joseph G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (07): : 838 - 840
  • [12] Technique for insertion of the inflow cannula of the INCOR left ventricular assist device
    Komoda, Takeshi
    Weng, Yuguo
    Hetzer, Roland
    ANNALS OF THORACIC SURGERY, 2008, 85 (04): : 1466 - 1467
  • [13] An Atypical Thrombus in the Inflow Cannula of the HeartWare Left Ventricular Assist Device
    Aissaoui, Nadia
    Paluszkiewicz, Lech
    Schulte-Eistrup, Sebastian
    Morshuis, Michiel
    Gummert, Jan
    ANNALS OF THORACIC SURGERY, 2011, 92 (03): : E57 - E57
  • [14] Computational analysis of thrombosis risk with variations in left ventricular assist device inflow cannula design in a multi-patient model
    Khamooshi, Mehrdad
    Azimi, Marjan
    Gregory, Shaun D.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 240
  • [15] Technique for Insertion of HeartMate II Left Ventricular Assist Device Inflow Cannula
    Soleimani, Behzad
    Stephenson, Edward R.
    Pae, Walter E.
    ANNALS OF THORACIC SURGERY, 2011, 91 (06): : 2001 - 2002
  • [16] Evaluation of Left Ventricular Assist Device Inflow Cannula Contact with Ventricular Wall on Cardiac CT
    Abramov, D.
    Weigold, G.
    Weissman, G.
    Ruiz, G.
    Mark, H.
    Cooper, L.
    Griffin, A.
    Boyce, S.
    Najjar, S. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S281 - S281
  • [17] Conventional and alternative sites for left ventricular assist device inflow and outflow cannula placement
    Loforte, Antonio
    Bottio, Tomaso
    Attisani, Matteo
    Suarez, Sofia Martin
    Tarzia, Vincenzo
    Pocar, Marco
    Botta, Luca
    Gerosa, Gino
    Rinaldi, Mauro
    Pacini, Davide
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (02) : 281 - 288
  • [18] Infective Endocarditis at the Inflow Cannula of Left Ventricular Assist Device After Barefoot Walking
    Kim, I.
    Lee, H.
    Lee, S.
    Kim, J.
    Kim, H.
    Hwang, I.
    Park, S.
    Sub, S. Kyung
    Kim, Y.
    Chang, W.
    Kim, J.
    Kim, H.
    Park, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S550 - S550
  • [19] In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery
    Hanke, Jasmin S.
    Krabatsch, Thomas
    Rojas, Sebastian V.
    Deniz, Ezin
    Ismail, Issam
    Martens, Andreas
    Shrestha, Malakh
    Haverich, Axel
    Netuka, Ivan
    Schmitto, Jan D.
    ARTIFICIAL ORGANS, 2017, 41 (03) : 272 - 275
  • [20] Neointima-inducing inflow cannula with titanium mesh for left ventricular assist device
    Yamada, Yukiko
    Nishinaka, Tomohiro
    Mizuno, Toshihide
    Taenaka, Yoshiyuki
    Tatsumi, Eisuke
    Yamazaki, Kenji
    JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (04) : 269 - 275