In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants

被引:58
作者
Rack, A. [1 ]
Rack, T. [2 ]
Stiller, M. [3 ]
Riesemeier, H. [4 ]
Zabler, S. [5 ]
Nelson, K. [2 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] Charite, Dept Oral & Maxillofacial Surg Clin Nav & Robot, Berlin, Germany
[3] Charite, Dept Maxillofacial & Facial Plast Surg, Div Oral Med Radiol & Surg, Berlin, Germany
[4] Bundesanstalt Mat Forsch & Prufung, Div Struct Anal, Berlin, Germany
[5] Tech Univ Berlin, Inst Mat Engn, D-1000 Berlin, Germany
关键词
X-ray imaging; dental implants; digital radiography; implant-abutment interface; X-RAY MICROTOMOGRAPHY; MARGINAL FIT; BESSY-II; TOMOGRAPHY; RESOLUTION; CT; CONFIGURATION; SYSTEMS; BAMLINE; LEAKAGE;
D O I
10.1107/S0909049510001834
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Micro-gap formation at the implant-abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 41 条
[21]   Toward high-contrast breast CT at low radiation dose [J].
Keyrilainen, Jani ;
Fernandez, Manuel ;
Karjalainen-Lindsberg, Marja-Liisa ;
Virkkunen, Pekka ;
Leidenius, Marjut ;
von Smitten, Karl ;
Sipila, Petri ;
Fiedler, Stefan ;
Suhonen, Heikki ;
Suortti, Pekka ;
Bravin, Alberto .
RADIOLOGY, 2008, 249 (01) :321-327
[22]   X-ray imaging with submicrometer resolution employing transparent luminescent screens [J].
Koch, A ;
Raven, C ;
Spanne, P ;
Snigirev, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (07) :1940-1951
[23]   In situ investigation of the discharge of alkaline Zn-MnO2 batteries with synchrotron x-ray and neutron tomographies [J].
Manke, I. ;
Banhart, J. ;
Haibel, A. ;
Rack, A. ;
Zabler, S. ;
Kardjilov, N. ;
Hilger, A. ;
Melzer, A. ;
Riesemeier, H. .
APPLIED PHYSICS LETTERS, 2007, 90 (21)
[24]  
MERICSKE-STERN R, 1992, International Journal of Oral and Maxillofacial Implants, V7, P185
[25]  
Morneburg TR, 2002, INT J PROSTHODONT, V15, P20
[26]   Production of the high-quality CdWO4 single crystals for application in CT and radiometric monitoring [J].
Nagornaya, L ;
Onyshchenko, G ;
Pirogov, E ;
Starzhinskiy, N ;
Tupitsyna, I ;
Ryzhikov, V ;
Galich, Y ;
Vostretsov, Y ;
Galkin, S ;
Voronkin, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2) :163-167
[27]   High resolution synchrotron-based radiography and tomography using hard X-rays at the BAMline (BESSY II) [J].
Rack, A. ;
Zabler, S. ;
Mueller, B. R. ;
Riesemeier, H. ;
Weldemann, G. ;
Lange, A. ;
Goebbels, J. ;
Hentschel, M. ;
Goerner, W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02) :327-344
[28]   Early pore formation in aluminium foams studied by synchrotron-based microtomography and 3-D image analysis [J].
Rack, A. ;
Helwig, H. -M. ;
Buetow, A. ;
Rueda, A. ;
Matijasevic-Lux, B. ;
Helfen, L. ;
Goebbels, J. ;
Banhart, J. .
ACTA MATERIALIA, 2009, 57 (16) :4809-4821
[29]   Synchrotron-based radioscopy employing spatio-temporal micro-resolution for studying fast phenomena in liquid metal foams [J].
Rack, A. ;
Garcia-Moreno, F. ;
Baumbach, T. ;
Banhart, J. .
JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 :432-434
[30]   Theoretical Considerations: Implant Positional Index Design [J].
Semper, W. ;
Kraft, S. ;
Krueger, T. ;
Nelson, K. .
JOURNAL OF DENTAL RESEARCH, 2009, 88 (08) :725-730