Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device

被引:78
|
作者
Kurian, Mathew [1 ]
Negalur, Nikhil [1 ]
Das, Sudeep [1 ]
Puttaiah, Narendra K. [1 ]
Haria, Dhawal [1 ]
Tejal, S. J. [1 ]
Thakkar, Maithil M. [1 ]
机构
[1] Narayana Nethralaya, Bangalore, Karnataka, India
关键词
INTRAOCULAR-LENS POWER; INTERFEROMETRY; ACCURACY;
D O I
10.1016/j.jcrs.2016.01.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the repeatability of a new swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and evaluate the agreement with an optical low-coherence reflectometry (OLCR) biometer (Lenstar 900) in cataractous eyes. SETTING: Tertiary eyecare facility. DESIGN: Prospective evaluation of a diagnostic test. METHODS: Eyes of patients had 3 consecutive scans acquired by the same operator. The repeatability of measurements was assessed using the within-subject standard deviation and coefficient of variation (CoV). Agreement between the mean measurements of each machine was evaluated. RESULTS: The study comprised 100 eyes of 100 patients. The median lens thickness and axial length (AL) measurements were significantly greater (P < .001) with SS-OCT (4.29 mm and 23.5 mm, respectively, versus 4.25 mm and 23.4 mm, respectively); anterior chamber depth (ACD) was greater with OLCR (2.72 mm versus 2.70 mm, respectively) (P < .001). The within-subject standard deviation and CoV of the AL (0.01 and 0.05, respectively) and the ACD (0.04 and 1.22, respectively) measurements showed lower variability with SS-OCT (0.05 and 0.21, respectively, for AL; 0.06 and 1.99, respectively, for ACD) than with OLCR. Good agreement was seen for anterior segment measurements between the 2 devices. The 95% limits of agreement of most parameters fell within the test retest variability of the parameters. The SS-OCT biometer also showed better penetration in dense posterior subcapsular cataracts, measuring AL successfully in 96% of cases. CONCLUSIONS: The new SS-OCT biometer showed good repeatability and agreement with the OLCR biometer. The SS-OCT biometer measured the AL with fewer dropouts compared with the OLCR even in dense cataracts. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:577 / 581
页数:5
相关论文
共 50 条
  • [41] Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation
    Roncevic, Mirjana Bjelos
    Busic, Mladen
    Cima, Ivan
    Elabjer, Biljana Kuzmanovic
    Bosnar, Damir
    Miletic, Daliborka
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (01) : 69 - 75
  • [42] Repeatability and Reproducibility of Biometry and Keratometry Measurements Using a Noncontact Optical Low-Coherence Reflectometer and Keratometer
    Shammas, H. John
    Hoffer, Kenneth J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (01) : 55 - 61
  • [43] Analysis of cracks and damages in optical elements by a swept-source optical coherence tomography technique
    Munoz Moreno, Gilberto
    Alcala Ochoa, Noe
    22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD, 2011, 8011
  • [44] Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients
    Chirapapaisan, Chareenun
    Srivannaboon, Sabong
    Chonpimai, Pratuangsri
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (03) : 186 - 191
  • [45] Evaluation of Axial Length Measurement Using Enhanced Retina Visualization Mode of the Swept-Source Optical Coherence Tomography Biometer in Dense Cataract
    Tamaoki, Akeno
    Kojima, Takashi
    Hasegawa, Asato
    Yamamoto, Mana
    Kaga, Tatsushi
    Tanaka, Kiyoshi
    Ichikawa, Kazuo
    OPHTHALMIC RESEARCH, 2021, 64 (04) : 595 - 603
  • [46] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Lei, Chak Seng
    Lin, Xuanqiao
    Ning, Rui
    Yu, Jinjin
    Huang, Xiaomin
    Li, Kexin
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3263 - 3279
  • [47] Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices
    Schiano-Lomoriello, Domenico
    Hoffer, Kenneth J.
    Abicca, Irene
    Savini, Giacomo
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] Comparison of preoperative and postoperative measurements of optical low-coherence reflectometry biometry and assessment of its refractive predictability
    Akalin, Irfan
    Tufek, Melek
    Turkyilmaz, Mustafa
    Ozturk, Faruk
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (06) : 1337 - 1343
  • [49] Laser Lens Size Measurement Using Swept-Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Qin, Yuwei
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [50] Akinetic Swept-Source Master-Slave-Enhanced Optical Coherence Tomography
    Marques, Manuel J.
    Cernat, Ramona
    Ensher, Jason
    Bradu, Adrian
    Podoleanu, Adrian
    PHOTONICS, 2021, 8 (05)