Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device

被引:78
|
作者
Kurian, Mathew [1 ]
Negalur, Nikhil [1 ]
Das, Sudeep [1 ]
Puttaiah, Narendra K. [1 ]
Haria, Dhawal [1 ]
Tejal, S. J. [1 ]
Thakkar, Maithil M. [1 ]
机构
[1] Narayana Nethralaya, Bangalore, Karnataka, India
关键词
INTRAOCULAR-LENS POWER; INTERFEROMETRY; ACCURACY;
D O I
10.1016/j.jcrs.2016.01.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the repeatability of a new swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and evaluate the agreement with an optical low-coherence reflectometry (OLCR) biometer (Lenstar 900) in cataractous eyes. SETTING: Tertiary eyecare facility. DESIGN: Prospective evaluation of a diagnostic test. METHODS: Eyes of patients had 3 consecutive scans acquired by the same operator. The repeatability of measurements was assessed using the within-subject standard deviation and coefficient of variation (CoV). Agreement between the mean measurements of each machine was evaluated. RESULTS: The study comprised 100 eyes of 100 patients. The median lens thickness and axial length (AL) measurements were significantly greater (P < .001) with SS-OCT (4.29 mm and 23.5 mm, respectively, versus 4.25 mm and 23.4 mm, respectively); anterior chamber depth (ACD) was greater with OLCR (2.72 mm versus 2.70 mm, respectively) (P < .001). The within-subject standard deviation and CoV of the AL (0.01 and 0.05, respectively) and the ACD (0.04 and 1.22, respectively) measurements showed lower variability with SS-OCT (0.05 and 0.21, respectively, for AL; 0.06 and 1.99, respectively, for ACD) than with OLCR. Good agreement was seen for anterior segment measurements between the 2 devices. The 95% limits of agreement of most parameters fell within the test retest variability of the parameters. The SS-OCT biometer also showed better penetration in dense posterior subcapsular cataracts, measuring AL successfully in 96% of cases. CONCLUSIONS: The new SS-OCT biometer showed good repeatability and agreement with the OLCR biometer. The SS-OCT biometer measured the AL with fewer dropouts compared with the OLCR even in dense cataracts. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:577 / 581
页数:5
相关论文
共 50 条
  • [31] Repeatability and Agreement of a Swept-Source Optical Coherence Tomography-Based Biometer IOLMaster 700 Versus a Scheimpflug Imaging-Based Biometer AL-Scan in Cataract Patients
    Chan, Tommy C. Y.
    Wan, Kelvin H.
    Tang, Fang Yao
    Wang, Yu Meng
    Yu, Marco
    Cheung, Carol
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (01): : 35 - 45
  • [32] Success Rate of Swept-Source Optical Coherence Tomography Biometry of Eyes of Elementary School Students
    Tomita, Masatoshi
    Yamashita, Takehiro
    Terasaki, Hiroto
    Yoshihara, Naoya
    Kakiuchi, Naoko
    Sakamoto, Taiji
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 3607 - 3612
  • [33] Accuracy and Repeatability of an Anterior Segment Swept-Source Optical Coherence Tomographer
    Peguda, Rajini
    Kang, Pauline
    Maseedupally, Vinod
    Swarbrick, Helen
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S300 - S306
  • [34] Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry
    Tana-Sanz, Pedro
    Rodriguez-Carrillo, Maria Dolores
    Ruiz-Santos, Maria
    Montes-Mico, Robert
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (12) : 1219 - 1234
  • [35] Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometer
    Huang, Jinhai
    Savini, Giacomo
    Wu, Fan
    Yu, Xinxin
    Yang, Jing
    Yu, Ayong
    Yu, Ye
    Wang, Qinmei
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10) : 2233 - 2241
  • [36] A new optical low coherence reflectometry device for ocular biometry in cataract patients
    Buckhurst, P. J.
    Wolffsohn, J. S.
    Shah, S.
    Naroo, S. A.
    Davies, L. N.
    Berrow, E. J.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (07) : 949 - 953
  • [37] Comparison of composite and segmental methods for acquiring optical axial length with swept-source optical coherence tomography
    Goto, So
    Maeda, Naoyuki
    Noda, Toru
    Ohnuma, Kazuhiko
    Koh, Shizuka
    Iehisa, Ikko
    Nishida, Kohji
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [38] Ocular biometry in dense cataracts: Comparison of partial-coherence interferometry, swept-source optical coherence tomography and immersion ultrasound
    Gonzalez-Godinez, Sara
    Saucedo-Urdapilleta, Roxana
    Mayorquin-Ruiz, Mariana
    Velasco-Barona, Cecilio
    Moragrega-Adame, Eduardo
    Dominguez-Varela, Irving A.
    Gonzalez-Salinas, Roberto
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (01) : 107 - +
  • [39] Evaluation of a new dynamic real-time visualization 25 kHz swept-source optical coherence tomography based biometer
    Yu, Jinjin
    Lin, Xuanqiao
    Huang, Xiaomin
    Xu, Zhenyu
    Ning, Rui
    Li, Kexin
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    EYE AND VISION, 2024, 11 (01)
  • [40] Comparative analysis of 2 swept-source optical coherence tomography biometers
    Sabatino, Francesco
    Matarazzo, Francesco
    Findl, Oliver
    Maurino, Vincenzo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (08) : 1124 - 1129