Twenty-four-hour efficacy of preservative-free tafluprost for open-angle glaucoma patients, assessed by home intraocular pressure (Icare-ONE) and blood-pressure monitoring

被引:7
作者
Cho, Soon Young [1 ]
Kim, Yong Yeon [2 ]
Yoo, Chungkwon [2 ]
Lee, Tae-Eun [2 ]
机构
[1] Dongguk Univ, Coll Med, Dept Ophthalmol, Gyeongju, South Korea
[2] Korea Univ, Coll Med, Dept Ophthalmol, Seoul 136705, South Korea
关键词
Intraocular pressure; Ocular perfusion pressure; Rebound tonometer; Tafluprost; GOLDMANN APPLANATION TONOMETER; LATERAL DECUBITUS POSITION; OCULAR PERFUSION-PRESSURE; REBOUND TONOMETER; VISUAL-FIELD; TOLERABILITY; HYPERTENSION; 0.0015-PERCENT; 0.005-PERCENT; LATANOPROST;
D O I
10.1007/s10384-015-0413-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the effect of preservative-free (PF) tafluprost on diurnal variation of intraocular pressure (IOP) and ocular perfusion pressure (OPP), measured by use of home IOP and blood-pressure (BP) monitoring devices, for primary open angle glaucoma (POAG) patients. Methods Twenty-two eyes from 22 patients with POAG were studied. Initially, IOP was measured at the hospital by Goldmann applanation tonometry (GAT) and Icare-ONE rebound tonometry. Each patient was then instructed how to use the Icare-ONE and BP home monitoring devices. IOP and BP were measured at home by the patients, every 4 h, before and 2 weeks after once daily treatment with PF tafluprost (0.0015 %) ophthalmic solution. Results Intraclass correlations between different IOP measurements were greater than 0.8. PF tafluprost reduced mean diurnal IOP significantly for patients with POAG, from 15.7 +/- 1.2 mmHg at baseline to 12.5 +/- 0.6 mmHg 2 weeks after treatment (p < 0.001). It increased mean diurnal OPP from 48.5 +/- 7.3 mmHg at baseline to 51.3 +/- 7.0 mmHg post-treatment (p < 0.017). Conclusions Icare-ONE enables glaucoma patients to measure their own diurnal IOP fluctuations. Patient-measured Icare-ONE IOP readings showed that PF tafluprost effectively reduced diurnal IOP in eyes with POAG.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 42 条
[1]   Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists [J].
Abraham, L. M. ;
Epasinghe, N. C. R. ;
Selva, D. ;
Casson, R. .
EYE, 2008, 22 (04) :503-506
[2]  
Anderson D.R., 1999, Automated static perimetry, V2nd
[3]  
Asrani S, 2000, J GLAUCOMA, V9, P134
[4]   Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device [J].
Asrani, Sanjay ;
Chatterjee, Ashmita ;
Wallace, David K. ;
Santiago-Turla, Cecilia ;
Stinnett, Sandra .
JOURNAL OF GLAUCOMA, 2011, 20 (02) :74-79
[5]   Randomized Clinical Trial of the Efficacy and Safety of Preservative-free Tafluprost and Timolol in Patients With Open-Angle Glaucoma or Ocular Hypertension [J].
Chabi, Almira ;
Varma, Rohit ;
Tsai, James C. ;
Lupinacci, Robert ;
Pigeon, Joseph ;
Baranak, Christine ;
Noble, Liliane ;
Lines, Christopher ;
Ho, Tony W. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (06) :1187-1196
[6]   Comparison of the effect of latanoprost 0.005% and timolol 0.5% on the calculated ocular perfusion pressure in patients with normal-tension glaucoma [J].
Drance, SM ;
Crichton, A ;
Mills, RP .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (05) :585-592
[7]   Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population [J].
Fernandes, P ;
Díaz-Rey, JA ;
Queirós, A ;
Gonzalez-Meijome, JM ;
Jorge, J .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (05) :436-440
[8]   Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjects [J].
Halkiadakis, Ioannis ;
Stratos, Aimilianos ;
Stergiopoulos, George ;
Patsea, Eleni ;
Skouriotis, Sotiris ;
Mitropoulos, Panagiotis ;
Papaconstantinou, Dimitrios ;
Georgopoulos, Gerasimos .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (08) :1207-1211
[9]   Reduction of intraocular pressure and glaucoma progression - Results from the early manifest glaucoma trial [J].
Heijl, A ;
Leske, MC ;
Bengtsson, B ;
Hyman, L ;
Bengtsson, B ;
Hussein, M .
ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (10) :1268-1279
[10]   IOP-lowering efficacy and tolerability of preservative-free tafluprost 0.0015% among patients with ocular hypertension or glaucoma [J].
Hommer, Anton ;
Ramez, Osman Mohammed ;
Burchert, Maria ;
Kimmich, Friedemann .
CURRENT MEDICAL RESEARCH AND OPINION, 2010, 26 (08) :1905-1913