Periprosthetic Bone Mineral Density Around Uncemented Titanium Stems in the Second and Third Decade After Total Hip Arthroplasty: A DXA Study After 12, 17 and 21 Years

被引:24
作者
Peitgen, David S. [1 ]
Innmann, Moritz M. [1 ]
Merle, Christian [1 ]
Gotterbarm, Tobias [1 ]
Moradi, Babak [1 ]
Streit, Marcus R. [1 ]
机构
[1] Heidelberg Univ, Ctr Orthopaed Trauma Surg & Spinal Cord Injury, Clin Orthopaed & Trauma Surg, Schlierbacher Landstr 200a, D-69118 Heidelberg, Germany
关键词
DXA; Cementless total hip replacement; Long-term follow-up; BMD; Periprosthetic fracture; Bone remodelling; X-RAY ABSORPTIOMETRY; FOLLOW-UP; PROXIMAL FEMUR; BMD; IMPLANTATION; FRACTURE; 10-YEAR; DESIGN; DEXA;
D O I
10.1007/s00223-018-0438-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implant failure and periprosthetic fractures because of periprosthetic bone loss are a major concern in total hip arthroplasty (THA). Hardly any clinical data exist on the long-term evolution of bone mineral density (BMD) around uncemented femoral implants. The question to address is whether relevant bone loss continues into third decade around well-fixed uncemented femoral implants. BMD around stable uncemented straight titanium femoral implants was assessed in a longitudinal cohort study. We included 142 hips of 128 patients and measured the development of the periprosthetic BMD using dual-energy X-ray absorptiometry. The baseline measurement was 12years (t(1)) after the implantation of an uncemented femoral stem. Follow-up-measurements were performed at 17 (t(2)) and at 21years (t(3)) after primary THA. The regions of interest (ROI) were selected conforming to Gruen et al. We acquired complete data including three consecutive measurements (t(1), t(2), t(3)) for 42 patients (49 hips). Performing radiographic evaluation at t(1), t(2) and t(3), we found a regular bone-implant interface present in all cases. Significant decrease in BMD could be shown in ROI 1 (p=0.0001; -7.8%), 4 (p=0.024; -2.4%), 6 (p=0.001; -5.5%) and 7 (p<0.0001; -11.7%) between t(1) and t(3) and in ROI 1 (p=0.002; -3.7%), 2 (p=0.046; -3.6%), 4 (p=0.002; -2.7%) and 7 (p<0.0001; -8.0%) between t(2) and t(3). There were significant differences in overall bone density (netavg) between t(1) and t(3) (p=0.001; -3.6%) and between t(2) and t(3) (p=0.020; -2.1%). The data indicate clinically relevant changes of BMD especially in the proximal Gruen zones in the long-term after uncemented THA. Loss of periprosthetic BMD might be a risk factor for periprosthetic fractures.
引用
收藏
页码:372 / 379
页数:8
相关论文
共 50 条
  • [41] Changes in Bone Mineral Density and Femoral Neck Narrowing in the Proximal Femur Three to Five Years After Hip Resurfacing Versus Conventional Total Hip Arthroplasty
    Gerhardt, Davey M. J. M.
    Smolders, Jose M. H.
    Rijnders, Ton A. J. M.
    Hol, Annemiek
    van Susante, Job L. C.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (02) : 308 - 314
  • [42] Larger Femoral Periprosthetic Bone Mineral Density Decrease Following Total Hip Arthroplasty for Femoral Neck Fracture Than for Osteoarthritis: A Prospective, Observational Cohort Study
    Mann, Tobias
    Eisler, Thomas
    Boden, Henrik
    Muren, Olle
    Stark, Andre
    Salemyr, Mats
    Skoldenberg, Olof
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (04) : 504 - 512
  • [43] Increased bone mineral density in the non-resurfaced patella after total knee arthroplasty: A clinical and densitometric study
    Di Martino, Alberto
    Franceschi, Francesco
    Papalia, Rocco
    Marini, Mario
    Prossomariti, Giancarlo
    Maffulli, Nicola
    Denaro, Vincenzo
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2012, 10 (01): : 20 - 24
  • [44] Proximal Femur Bone Density Decreases up to 5 Years After Total Hip Arthroplasty in Young, Active Patients
    Nam, Denis
    Barrack, Robert L.
    Clohisy, John C.
    Nunley, Ryan M.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12) : 2825 - 2830
  • [45] Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study
    Conrad Anderl
    Georg Mattiassich
    Reinhold Ortmaier
    Martin Steinmair
    Josef Hochreiter
    BMC Musculoskeletal Disorders, 21
  • [46] Denosumab Prevents Early Periprosthetic Bone Loss After Uncemented Total Hip Arthroplasty: Results from a Randomized Placebo-Controlled Clinical Trial
    Nystrom, Andreas
    Kiritopoulos, Demostenis
    Ullmark, Gosta
    Sorensen, Jens
    Petren-Mallmin, Marianne
    Milbrink, Jan
    Hailer, Nils P.
    Mallmin, Hans
    JOURNAL OF BONE AND MINERAL RESEARCH, 2020, 35 (02) : 239 - 247
  • [47] Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femur
    Ohashi, Yoshihisa
    Fukushima, Kensuke
    Tsuchiya, Maho
    Saito, Hiroki
    Uchida, Kentaro
    Uchiyama, Katsufumi
    Takahira, Naonobu
    Takaso, Masashi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (08) : 3739 - 3748
  • [48] Bone Mineral Density Changes in the Hip and Spine of Men and Women 1-Year After Primary Cemented Total Knee Arthroplasty: Prospective Cohort Study
    Beaupre, Lauren A.
    Rezansoff, Alexander
    Clark, Marcia
    Jen, Ho
    Lambert, Robert G.
    Majumdar, Sumit
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12) : 2185 - 2189
  • [49] Bisphosphonates for the preservation of periprosthetic bone mineral density after total joint arthroplasty: a meta-analysis of 25 randomized controlled trials
    Shi, M.
    Chen, L.
    Xin, Z.
    Wang, Y.
    Wang, W.
    Yan, S.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 (07) : 1525 - 1537
  • [50] Efficiency of Zoledronic Acid in Inhibiting Accelerated Periprosthetic Bone Loss After Cementless Total Hip Arthroplasty in Osteoporotic Patients: A Prospective, Cohort Study
    Fu, Guang-tao
    Lin, Li-jun
    Sheng, Pu-yi
    Li, Chang-chuan
    Zhang, Jin-xin
    Shen, Jun
    Liu, Sheng
    Xue, Yun-lian
    Lin, Si-peng
    Wang, Kun
    Zheng, Qiu-jian
    Ding, Yue
    ORTHOPAEDIC SURGERY, 2019, 11 (04) : 653 - 663