Effect of microwave heating damage on the electrical, thermal and mechanical properties of fibre-reinforced cement mortars

被引:20
作者
Borinaga-Trevino, R. [1 ]
Orbe, A. [1 ]
Norambuena-Contreras, J. [2 ]
Canales, J. [1 ]
机构
[1] Univ Basque Country UPV EHU, Dept Mech Engn, Plaza Ingeniero Torres Quevedo 1, Bilbao 48013, Spain
[2] Univ Bio Bio, Dept Civil & Environm Engn, LabMAT, Concepcion, Chile
基金
欧盟地平线“2020”;
关键词
Cement-based mortars; Microwave heating; Thermal conductivity; Electrical resistivity; Mechanical damage; Fibre influence; HIGH EARLY STRENGTH; CONCRETE; CONDUCTIVITY; DIFFUSIVITY;
D O I
10.1016/j.conbuildmat.2018.07.108
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nowadays, refurbishing of existing structures has gained interest in order to reduce both the construction materials used and the construction and demolition waste production. For that purpose, there are several methods for demolishing the damaged parts, but most of the alternatives involve high noise and dust production, which are in contraposition when structures are in urban areas. Among all the existing methods, this paper studies the possibility of using microwave heating as a demolition method, either by damaging the bulk material or the mortar to concrete interface. With that in mind, the effect of microwave heating time (range 120-600 s) on the physical, thermal, electrical, mechanical and bonding properties of steel fibre-reinforced and non-reinforced cement mortars was analysed. The aim of the paper is to establish possible correlations between the mentioned properties and the damage level caused by microwave heating. Although the results prove that pore pressure increment due to microwave heating can cause the reduction of flexural strength up to the rupture of the specimens, this fact cannot be extended to all the properties or mortar types. The fibre reinforcement plays a key role to restrain the damage. Thermal conductivity and electrical resistivity are obviously different in reinforced and non-reinforced mortars due to the inclusions of the metallic fibres. However, after undergoing microwave heating those properties were not noticeably altered nor follow a trend linked to the heating time. It is assumed that the water migration and evaporation processes are the main cause. Although the flexural strength reduction was gradual for non-reinforced mortars until total failure, the reinforced specimens only showed a 13% of reduction for the first 120 s, remaining almost constant afterwards. Although it was proved that the fibres increase the temperature on the specimen surface and its adhesion to the matrix is altered, their crack bridging effect overcomes further damage. (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:31 / 41
页数:11
相关论文
共 35 条
[1]   Microwave-assisted beneficiation of recycled concrete aggregates [J].
Akbarnezhad, A. ;
Ong, K. C. G. ;
Zhang, M. H. ;
Tam, C. T. ;
Foo, T. W. J. .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (08) :3469-3479
[2]   Measurements of thermal properties of insulation materials by using transient plane source technique [J].
Al-Ajlan, Saleh A. .
APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) :2184-2191
[3]  
[Anonymous], 2007, 15046 EN
[4]  
[Anonymous], 2006, 15043 EN
[5]  
[Anonymous], 2007, 101511 UNEEN
[6]  
[Anonymous], 2007, 101510 UNEEN
[7]  
Bentur A, 2006, FIBRE REINFORCED CEM, DOI DOI 10.1201/9781482267747
[8]   Transient plane source measurements of the thermal properties of hydrating cement pastes [J].
Bentz, D. P. .
MATERIALS AND STRUCTURES, 2007, 40 (10) :1073-1080
[9]   Measurement of thermal conductivity, thermal diffusivity and heat capacity of highly porous building materials using transient plane source technique [J].
Bouguerra, A ;
Aït-Mokhtar, A ;
Amiri, O ;
Diop, MB .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2001, 28 (08) :1065-1078
[10]   Use of microwaves for damage detection of fiber reinforced polymer-wrapped concrete structures [J].
Feng, MQ ;
De Flaviis, F ;
Kim, YJ .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 2002, 128 (02) :172-183