MR thermometry for monitoring tumor ablation

被引:121
作者
de Senneville, Baudouin Denis
Mougenot, Charles
Quesson, Bruno
Dragonu, Iulius
Grenier, Nicolas
Moonen, Chrit T. W.
机构
[1] Univ Bordeaux 2, Lab Mol & Funct Imaging, CNRS, F-33076 Bordeaux, France
[2] Phillips Systemes Med, F-92156 Suresnes, France
[3] CHU Pellegrin, Serv Radiol, Bordeaux, France
关键词
MRI; thermometry; therapy;
D O I
10.1007/s00330-007-0646-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Local thermal therapies are increasingly used in the clinic for tissue ablation. During energy deposition, the actual tissue temperature is difficult to estimate since physiological processes may modify local heat conduction and energy absorption. Blood flow may increase during temperature increase and thus change heat conduction. In order to improve the therapeutic efficiency and the safety of the intervention, mapping of temperature and thermal dose appear to offer the best strategy to optimize such interventions and to provide therapy endpoints. MRI can be used to monitor local temperature changes during thermal therapies. On-line availability of dynamic temperature mapping allows prediction of tissue death during the intervention based on semi-empirical thermal dose calculations. Much progress has been made recently in MR thermometry research, and some applications are appearing in the clinic. In this paper, the principles of MRI temperature mapping are described with special emphasis on methods employing the temperature dependency of the water proton resonance frequency. Then, the prospects and requirements for widespread applications of MR thermometry in the clinic are evaluated.
引用
收藏
页码:2401 / 2410
页数:10
相关论文
共 76 条
[1]  
Atsumi Hideki, 2005, Nihon Rinsho, V63 Suppl 9, P495
[2]   Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study [J].
Aubé, C ;
Schmidt, D ;
Brieger, J ;
Schenk, M ;
Helmberger, T ;
Koenig, CW ;
Schick, F ;
Claussen, CD ;
Pereira, PL .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (04) :385-392
[3]  
BENNETT WR, 1962, ELECT NOISE
[4]   Large liver tumors: Protocol for radiofrequency ablation and its clinical application in 110 patients - Mathematic model, overlapping mode, and electrode placement process [J].
Chen, MH ;
Yang, W ;
Yan, K ;
Zou, MW ;
Solbiati, L ;
Liu, LB ;
Dai, Y .
RADIOLOGY, 2004, 232 (01) :260-271
[5]   MR-GUIDED FOCUSED ULTRASOUND SURGERY [J].
CLINE, HE ;
SCHENCK, JF ;
HYNYNEN, K ;
WATKINS, RD ;
SOUZA, SP ;
JOLESZ, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :956-965
[6]   MR TEMPERATURE MAPPING OF FOCUSED ULTRASOUND SURGERY [J].
CLINE, HE ;
HYNYNEN, K ;
HARDY, CJ ;
WATKINS, RD ;
SCHENCK, JF ;
JOLESZ, FA .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :628-636
[7]   Palliative endoscopic treatments for esophageal cancers [J].
Dahan, L ;
Ries, P ;
Laugier, R ;
Seitz, JF .
GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2006, 30 (02) :253-261
[8]   Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound [J].
de Senneville, Baudouin Denis ;
Mougenot, Charles ;
Moonen, Chrit T. W. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) :319-330
[9]   Magnetic resonance temperature imaging [J].
De Senneville, BD ;
Quesson, B ;
Moonen, CTW .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2005, 21 (06) :515-531
[10]  
de Zwart JA, 1999, MAGNET RESON MED, V42, P53, DOI 10.1002/(SICI)1522-2594(199907)42:1<53::AID-MRM9>3.0.CO