Performance of an A1C and Fasting Capillary Blood Glucose Test for Screening Newly Diagnosed Diabetes and Pre-Diabetes Defined by an Oral Glucose Tolerance Test in Qingdao, China

被引:111
作者
Zhou, Xianghai [3 ,4 ,5 ]
Pang, Zengchang [1 ]
Gao, Weiguo [2 ,3 ]
Wang, Shaojie [1 ]
Zhang, Lei [2 ,3 ]
Ning, Feng [3 ]
Qiao, Qing [2 ,3 ]
机构
[1] Qingdao Ctr Dis Control & Prevent, Qingdao, Peoples R China
[2] Natl Inst Hlth & Welf, Diabet Prevent Unit, Helsinki, Finland
[3] Univ Helsinki, Dept Publ Hlth, Helsinki, Finland
[4] Peking Univ, Peoples Hosp, Dept Endocrinol & Metab, Beijing 100871, Peoples R China
[5] Peking Univ, Ctr Diabet, Beijing 100871, Peoples R China
关键词
PLASMA-GLUCOSE; CARDIOVASCULAR-DISEASE; US POPULATION; FOLLOW-UP; HEMOGLOBIN; RISK; MORTALITY; FRUCTOSAMINE; ASSOCIATION; PREVALENCE;
D O I
10.2337/dc09-1410
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - The study's goal was to evaluate the performance of A] C and lasting capillary blood glucose (FCG) tests as mass screening tools for diabetes and pre-diabetes, as determined by the standard oral glucose tolerance test (OGTT). RESEARCH DESIGN AND METHODS - Data from 2,332 individuals aged 35-74 years who participated in a population-based cross-sectional diabetes survey in Qingdao, China, were analyzed. A 2-h 75-g OGTT was used to diagnose diabetes. The performance of A1C and FCG was evaluated against the results of the OGTTs by using receiver operating characteristic curve (ROC) analysis. RESULTS - The prevalence of newly diagnosed diabetes and pre-diabetes (impaired fasting glucose and/or impaired glucose tolerance) was 11.9 and 29.5%, respectively. For subjects with newly diagnosed diabetes, the area under the ROC curve was 0.67 for A1C and 0.77 for FCG (P < 0.01) in men and 0.67 and 0.75 (P < 0.01) in women, whereas for pre-diabetes, these values were 0.47 and 0.64 (P < 0.001) in men and 0.51 and 0.65 (P < 0.001.) in women. At the optimal A1C cutoff point of >= 5.6% for newly diagnosed diabetes, sensitivities (specificities) were 64.4% (61.6%) for men and 62.3% (63.3%) for women. CONCLUSIONS - As a screening tool for newly diagnosed diabetes and pre-diabetes, the FCG measurement performed better than A I C in this general Chinese population.
引用
收藏
页码:545 / 550
页数:6
相关论文
共 25 条
[1]   Understanding diagnostic tests 3: receiver operating characteristic curves [J].
Akobeng, Anthony K. .
ACTA PAEDIATRICA, 2007, 96 (05) :644-647
[2]  
[Anonymous], DIABETES CARE
[3]  
[Anonymous], 1999, WHO/NCD/ NCS/99.2
[4]  
[Anonymous], DIABETES CARE
[5]   Kinetics of Insulin Secretion from MIN6 Pseudoislets after Encapsulation in a Prototype Device of a Bioartificial Pancreas [J].
Barrientos, R. ;
Baltrusch, S. ;
Sigrist, S. ;
Legeay, G. ;
Belcourt, A. ;
Lenzen, S. .
HORMONE AND METABOLIC RESEARCH, 2009, 41 (01) :5-9
[6]   THE ROC CURVE IN THE EVALUATION OF FASTING CAPILLARY BLOOD-GLUCOSE AS A SCREENING-TEST TOR DIABETES AND IGT [J].
BORTHEIRY, AL ;
MALERBI, DA ;
FRANCO, LJ .
DIABETES CARE, 1994, 17 (11) :1269-1272
[7]   Utility of AIC for diabetes screening in the 1999-2004 NHANES population [J].
Buell, Catherine ;
Kermah, Duclie ;
Davidson, Mayer B. .
DIABETES CARE, 2007, 30 (09) :2233-2235
[8]   Screening for type 2 diabetes and impaired glucose metabolism [J].
Colagiuri, S ;
Hussain, Z ;
Zimmet, P ;
Cameron, A ;
Shaw, J .
DIABETES CARE, 2004, 27 (02) :367-371
[9]   Concordance between fasting and 2-h post-glucose challenge criteria for the diagnosis of diabetes mellitus and glucose intolerance in high risk individuals [J].
Drzewoski, J ;
Czupryniak, L .
DIABETIC MEDICINE, 2001, 18 (01) :29-31
[10]   Reproducibility of the diagnosis of diabetes over a 30-month follow-up -: The Paris Prospective Study [J].
Eschwège, E ;
Charles, MA ;
Simon, D ;
Thibult, N ;
Balkau, B .
DIABETES CARE, 2001, 24 (11) :1941-1944