Monitoring of amoxicilline and ceftazidime in the microdialysate of diabetic foot and serum by capillary electrophoresis with contactless conductivity detection

被引:16
|
作者
Tuma, Petr [1 ]
Jacek, Martin [1 ]
Sommerova, Blanka [1 ]
Dlouhy, Pavel [1 ]
Jarosikova, Radka [2 ]
Husakova, Jitka [2 ]
Woskova, Veronika [2 ]
Fejfarova, Vladimira [2 ]
机构
[1] Charles Univ Prague, Fac Med 3, Dept Hyg, Ruska 87, Prague 10000 10, Czech Republic
[2] Inst Clin & Expt Med, Diabet Ctr, Prague 4, Czech Republic
关键词
antibiotic; CE; contactless conductivity detection; diabetic foot; microdialysis; BETA-LACTAM ANTIBIOTICS; HUMAN PLASMA; SENSITIVE DETERMINATION; CEREBROSPINAL-FLUID; RAPID-DETERMINATION; CLAVULANIC ACID; HUMAN BLOOD; HPLC-DAD; CHROMATOGRAPHY; TOBRAMYCIN;
D O I
10.1002/elps.202100366
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Determination of the broad-spectrum antibiotics amoxicilline (AMX) and ceftazidime (CTZ) in blood serum and microdialysates of the subcutaneous tissue of the lower limbs is performed using CE with contactless conductivity detection ((CD)-D-4). Baseline separation of AMX is achieved in 0.5 M acetic acid as the background electrolyte and separation of CTZ in 3.2 M acetic acid with addition of 13% v/v methanol. The CE-(CD)-D-4 determination is performed in a 25 mu m capillary with suppression of the EOF using INST-coating on an effective length of 18 cm and the attained migration time is 4.2 min for AMX and 4.4 min for CTZ. The analysis was performed using 20 mu l of serum and 15 mu l of microdialysate, treated by the addition of acetonitrile in a ratio of 1/3 v/v and the sample is injected into the capillary using the large volume sample stacking technique. The LOQ attained in the microdialysate is 148 ng/ml for AMX and 339 ng/ml for CTZ, and in serum 143 ng/ml for AMX and 318 ng/ml for CTZ. The CE-(CD)-D-4 method is employed for monitoring the passage of AMX and CTZ from the blood circulatory system into the subcutaneous tissue at the sites of diabetic ulceration in patients suffering from diabetic foot syndrome and also for measuring the pharmacokinetics following intravenous application of bolus antibiotic doses.
引用
收藏
页码:1129 / 1139
页数:11
相关论文
共 50 条
  • [41] Enantioseparation of tartaric acid by ligand-exchange capillary electrophoresis using contactless conductivity detection
    Knob, Radim
    Petr, Jan
    Sevcik, Juraj
    Maier, Vitezslav
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (20) : 3426 - 3431
  • [42] Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection
    Gregus, Michal
    Foret, Frantisek
    Kindlova, Dagmar
    Pokojova, Eva
    Plutinsky, Marek
    Doubkova, Martina
    Merta, Zdenek
    Binkova, Ilona
    Skrickova, Jana
    Kuban, Petr
    JOURNAL OF BREATH RESEARCH, 2015, 9 (02)
  • [43] Determination of free and total valproic acid in human plasma by capillary electrophoresis with contactless conductivity detection
    Thi Thanh Thuy Pham
    See, Hong Heng
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 907 : 74 - 78
  • [44] Capillary electrophoresis with contactless conductivity detection for the determination of carnitine and acylcarnitines in clinical samples
    Pormsila, Worapan
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 921 - 926
  • [45] Contactless Conductivity Detection in Capillary Electrophoresis in Combination with Capillaries with Thin Inner Diameter
    Tuma, Petr
    Samcova, Eva
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 168 - 172
  • [46] Analysis of electroplating baths by capillary electrophoresis with high voltage contactless conductivity detection
    Zhang, Ling
    Khaloo, Shokooh S.
    Kuban, Pavel
    Hauser, Peter C.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (12) : 3317 - 3322
  • [47] Determination of carnitine in food and food supplements by capillary electrophoresis with contactless conductivity detection
    Pormsila, Worapan
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    ELECTROPHORESIS, 2010, 31 (13) : 2186 - 2191
  • [48] Capillary electrophoresis with contactless conductivity detection coupled to a sequential injection analysis manifold for extended automated monitoring applications
    Thanh Duc Mai
    Schmid, Stefan
    Mueller, Beat
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2010, 665 (01) : 1 - 6
  • [49] Capillary electrophoresis with contactless conductivity detection for uric acid determination in biological fluids
    Pormsila, Worapan
    Krahenbuehl, Stephan
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2009, 636 (02) : 224 - 228
  • [50] Rapid monitoring of mono- and disaccharides in drinks, foodstuffs and foodstuff additives by capillary electrophoresis with contactless conductivity detection
    Tuma, Petr
    Malkova, Klara
    Samcova, Eva
    Stulik, Karel
    ANALYTICA CHIMICA ACTA, 2011, 698 (1-2) : 1 - 5