3D fitting accuracy evaluation of CAD/CAM copings - comparison with spacer design settings

被引:0
作者
Boitelle, P. [1 ,4 ]
Tapie, L. [2 ,4 ]
Mawussi, B. [2 ,4 ]
Fromentin, O. [3 ,4 ]
机构
[1] Lille Nord France Univ, Fac Dent Surg, Dept Prosthodont, Cayenne, French Guiana
[2] Univ Paris 13, Sorbonne Paris Cite Univ Consortium, Fac Mech Engn, F-93430 Villetaneuse, France
[3] Paris Diderot Univ, Sorbonne Paris Cite, Hosp Rothschild, AP HP,Prosthodont Dept,Fac Dent Surg, Paris, France
[4] Paris Diderot Univ, Fac Dent Surg, Dent Mat URB2i, Paris, France
关键词
3D accuracy of evaluation; accuracy of fit; CAD/CAM; dental prostheses; design parameters; FIXED PARTIAL DENTURES; ZIRCONIA CROWN COPINGS; ALL-CERAMIC CROWNS; SINGLE-TOOTH RESTORATIONS; MARGINAL FIT; INTERNAL FIT; DENTAL PROSTHESES; IN-VITRO; LUTING AGENTS; MANUFACTURING PROCESSES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The accuracy of computer-aided design/computer-aided manufacturing (CAD/CAM) systems is linked to their technical characteristics and reliability for manufacturing the restoration designed. The aim of this study was to compare the accuracy of fit of zirconia copings manufactured with different CAD/CAM systems and their capacity to conform to pre-established spacer design settings. Methods: Sixty zirconia copings were manufactured by three CAD/CAM systems, with their spacers set as recommended by their manufacturer on occlusal, axial, and marginal surfaces. The 3D triple-scan optical technique was used to obtain a fit mapping and to analyze the marginal and axial accuracy of fit. The reliability of the 3D measurement method was estimated using intraclass correlation and repeatability coefficients. The preparation coping interface width results were statistically analyzed using non-parametric analysis (Kruskal-Wallis, one-way ANOVA, and Wilcoxon signed rank tests) (P < 0.05). Results: The repeatability coefficient was 6, 8, and 15 mu m for axial, marginal, and occlusal interface width measurements, respectively. For the three systems tested, no differences were found in the marginal area of the copings studied, with a mean fitting accuracy ranging from 54.3 to 66.6 mu m interface width. Statistically significant differences between groups were observed for the fitting accuracy measured in axial and occlusal areas. With the spacers set in the different areas, mean fit measurements of the zirconia copings were significantly larger, with an increased fit width ranging from 30 to 73 mu m. Significance: The three CAD/CAM systems evaluated allowed similar marginal accuracy but failed to reproduce the pre-established spacer parameters, with larger spacing showing throughout.
引用
收藏
页码:27 / 43
页数:17
相关论文
共 75 条
  • [1] Internal adaptation, marginal accuracy and microleakage of a pressable versus a machinable ceramic laminate veneers
    Aboushelib, Moustafa Nabil
    Elmahy, Waleed AbdelMeguid
    Ghazy, Mohammed Hamed
    [J]. JOURNAL OF DENTISTRY, 2012, 40 (08) : 670 - 677
  • [2] Machining variability impacts on the strength of a 'chair-side' CAD-CAM ceramic
    Addison, Owen
    Cao, Xu
    Sunnar, Parminder
    Fleming, Garry J. P.
    [J]. DENTAL MATERIALS, 2012, 28 (08) : 880 - 887
  • [3] AL-Rabab'ah MA, 2008, EUR J PROSTHODONT RE, V16, P109
  • [4] The Effect of Different Fabrication Steps on the Marginal Adaptation of Two Types of Glass-Infiltrated Ceramic Crown Copings Fabricated by CAD/CAM Technology
    Alghazzawi, Tariq F.
    Liu, Perng-Ru
    Essig, Milton E.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (03): : 167 - 172
  • [5] [Anonymous], 1977, 81977 ANSADA
  • [6] [Anonymous], 74891986 ISO
  • [7] Marginal and Internal Discrepancies Related to Margin Design of Ceramic Crowns Fabricated by a CAD/CAM System
    Assuncao Souza, Rodrigo Othavio
    Ozcan, Mutlu
    Pavanelli, Carlos Augusto
    Buso, Leonardo
    Leao Lombardo, Geraldo Henrique
    Araujo Michida, Silvia Masae
    Melo Mesquita, Alfredo Mikail
    Bottino, Marco Antonio
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (02): : 94 - 100
  • [8] Marginal Adaptation of All-Ceramic Crowns on Implant Abutments
    Att, Wael
    Hoischen, Tomas
    Gerds, Thomas
    Strub, Joerg Rudolf
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (04) : 218 - 225
  • [9] Azar MS, 2011, INT J PROSTHODONT, V24, P264
  • [10] FIT OF 3 PORCELAIN-FUSED-TO-METAL MARGINAL DESIGNS INVIVO - A SCANNING ELECTRON-MICROSCOPE STUDY
    BELSER, UC
    MACENTEE, MI
    RICHTER, WA
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (01) : 24 - 29