Bismuth breast-shield use in chest computed tomography for efficient dose reduction and sufficient image quality

被引:5
|
作者
Ko, Chih-Hsiang [1 ,2 ]
Lee, Shiou-Ping [2 ]
Hsieh, Yi-Chien [1 ,2 ]
Lee, Yuan-Hao [1 ]
Yao, Melissa Min-Szu [1 ,2 ]
Chan, Wing P. [1 ,2 ]
机构
[1] Taipei Med Univ, Wan Fang Hosp, Dept Radiol, 111 Hsing Long Rd,Sec 3, Taipei 116, Taiwan
[2] Taipei Med Univ, Coll Med, Sch Med, Dept Radiol, Taipei, Taiwan
关键词
breast shield; computed tomography scan; image quality; radiation dose; safety; TUBE CURRENT MODULATION; THORACIC CT; FEMALE BREAST; RADIATION-EXPOSURE; MDCT;
D O I
10.1097/MD.0000000000026277
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Radiosensitivity in the breasts increases the risk of carcinogenesis from exposure to the ionizing radiation of computed tomography (CT) administered in the course of medical attention. Bismuth shielding techniques have been used to reduce radiation, but image noise increased, degrading image quality. Purpose: The aim of this study was to investigate how the use of iterative reconstruction (IR) combined with bismuth shielding influences image quality. Materials and Methods: Women aged at least 20 years with body mass indexes <28 were recruited and randomly assigned to 1 of 3 CT scanning protocols without shielding, with a bismuth breast shield before the scout view, or with a bismuth breast shield after the scout view. All obtained images were reconstructed using an IR algorithm. To evaluate radiation dose, 2 Gafchromic films were placed over the clothes, 1 near each nipple. Results: Average dose reduction was significant (27.99%, P < .05) when bismuth shielding was applied after the scout view. Using the contrast-to-noise ratio, the image quality was found to be superior when the IR algorithm was applied. Using quantitative evaluations by 2 radiologists applying a 4-point Likert scale, significant differences in image quality were not found among the 3 protocols. Conclusion: Bismuth breast shields, particularly when used after acquiring scout images, are effective at reducing radiation dose without undermining the diagnostic value of the images when the IR technique is applied.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
    Leipsic, Jonathon
    Nguyen, Giang
    Brown, Jaqueline
    Sin, Don
    Mayo, John R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1095 - 1099
  • [42] Low dose computed tomography pulmonary angiography protocol for imaging pregnant patients: Can dose reduction be achieved without reducing image quality?
    Halpenny, Darragh
    Park, Brian
    Alpert, Jeffrey
    Latson, Larry, Jr.
    Kim, Nancy
    Babb, James
    Shiau, Maria
    Ko, Jane
    CLINICAL IMAGING, 2017, 44 : 101 - 105
  • [43] Introducing SRF in Bismuth-Silicon and Polyurethane shields for breast dose reduction during chest CT
    Mehnati, Parinaz
    Sargazi, Vida
    Sotoodeh, Zainab Yazdi
    Nejadjahantigh, Afshin
    Farsizaban, Masoome
    JOURNAL OF COMPLEMENTARY MEDICINE RESEARCH, 2020, 11 (05): : 195 - 203
  • [44] Dual-Energy Computed Tomography: Is There a Penalty in Image Quality and Radiation Dose Compared With Single-Energy Computed Tomography?
    Thomas, Christoph
    Ketelsen, Dominik
    Tsiflikas, Ilias
    Reimann, Anja
    Brodoefel, Harald
    Claussen, Claus D.
    Heuschmid, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 309 - 315
  • [45] Image quality vs radiation dose of four cone beam computed tomography scanners
    Loubele, M.
    Jacobs, R.
    Maes, F.
    Denis, K.
    White, S.
    Coudyzer, W.
    Lambrichts, I.
    van Steenberghe, D.
    Suetens, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (06) : 309 - 318
  • [46] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Nicolò Schicchi
    Marco Fogante
    Matteo Oliva
    Paolo Esposto Pirani
    Giacomo Agliata
    Gian Marco Giuseppetti
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 184 - 190
  • [47] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Schicchi, Nicolo
    Fogante, Marco
    Oliva, Matteo
    Pirani, Paolo Esposto
    Agliata, Giacomo
    Giuseppetti, Gian Marco
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (03): : 184 - 190
  • [48] Assessment of dose reduction and image quality by barium composite shielding in head and chest CT
    Lee, Jong-Woong
    Kweon, Dae Cheol
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2020, 175 (9-10): : 809 - 826
  • [49] Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Hanaoka, Shinsuke
    Matsubara, Kosuke
    Takata, Tadanori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 246 - 251
  • [50] Impact of a 4th Generation Iterative Reconstruction Technique on Image Quality in Low-Dose Computed Tomography of the Chest in Immunocompromised Patients
    Laqmani, A.
    Buhk, J. H.
    Henes, F. O.
    Klink, T.
    Sehner, S.
    von Schultzendorff, H. C.
    Hammerle, D.
    Nagel, H. D.
    Adam, G.
    Regier, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (08): : 749 - 757