Bismuth breast-shield use in chest computed tomography for efficient dose reduction and sufficient image quality

被引:5
|
作者
Ko, Chih-Hsiang [1 ,2 ]
Lee, Shiou-Ping [2 ]
Hsieh, Yi-Chien [1 ,2 ]
Lee, Yuan-Hao [1 ]
Yao, Melissa Min-Szu [1 ,2 ]
Chan, Wing P. [1 ,2 ]
机构
[1] Taipei Med Univ, Wan Fang Hosp, Dept Radiol, 111 Hsing Long Rd,Sec 3, Taipei 116, Taiwan
[2] Taipei Med Univ, Coll Med, Sch Med, Dept Radiol, Taipei, Taiwan
关键词
breast shield; computed tomography scan; image quality; radiation dose; safety; TUBE CURRENT MODULATION; THORACIC CT; FEMALE BREAST; RADIATION-EXPOSURE; MDCT;
D O I
10.1097/MD.0000000000026277
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Radiosensitivity in the breasts increases the risk of carcinogenesis from exposure to the ionizing radiation of computed tomography (CT) administered in the course of medical attention. Bismuth shielding techniques have been used to reduce radiation, but image noise increased, degrading image quality. Purpose: The aim of this study was to investigate how the use of iterative reconstruction (IR) combined with bismuth shielding influences image quality. Materials and Methods: Women aged at least 20 years with body mass indexes <28 were recruited and randomly assigned to 1 of 3 CT scanning protocols without shielding, with a bismuth breast shield before the scout view, or with a bismuth breast shield after the scout view. All obtained images were reconstructed using an IR algorithm. To evaluate radiation dose, 2 Gafchromic films were placed over the clothes, 1 near each nipple. Results: Average dose reduction was significant (27.99%, P < .05) when bismuth shielding was applied after the scout view. Using the contrast-to-noise ratio, the image quality was found to be superior when the IR algorithm was applied. Using quantitative evaluations by 2 radiologists applying a 4-point Likert scale, significant differences in image quality were not found among the 3 protocols. Conclusion: Bismuth breast shields, particularly when used after acquiring scout images, are effective at reducing radiation dose without undermining the diagnostic value of the images when the IR technique is applied.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Hyun-Hae Cho
    So Mi Lee
    Sun Kyoung You
    Pediatric Radiology, 2020, 50 : 242 - 251
  • [32] Radiation dose reduction in computed skeletal radiography - Effect on image quality
    Jonsson, A
    Herrlin, K
    Jonsson, K
    Lundin, B
    Sanfridsson, J
    Pettersson, H
    ACTA RADIOLOGICA, 1996, 37 (02) : 128 - 133
  • [33] Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality
    Lee, Youkyung
    Jin, Kwang Nam
    Lee, Nyoung Keun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 512 - 517
  • [34] Computed Tomography Radiation Dose Reduction: Effect of Different Iterative Reconstruction Algorithms on Image Quality
    Willemink, Martin J.
    Takx, Richard A. P.
    de Jong, Pim A.
    Budde, Ricardo P. J.
    Bleys, Ronald L. A. W.
    Das, Marco
    Wildberger, Joachim E.
    Prokop, Mathias
    Buls, Nico
    de Mey, Johan
    Leiner, Tim
    Schilham, Arnold M. R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 815 - 823
  • [35] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [36] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [37] Digital chest radiography image quality assessment with dose reduction
    R. K. Grewal
    N. Young
    L. Collins
    N. Karunaratne
    R. Sabharwal
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 71 - 80
  • [38] Digital chest radiography image quality assessment with dose reduction
    Grewal, R. K.
    Young, N.
    Collins, L.
    Karunaratne, N.
    Sabharwal, R.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 71 - 80
  • [39] Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Yu, Lifeng
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (11) : 6084 - 6092
  • [40] A cross-sectional study on the correlation of image quality, effective dose, and body composition with thyroid, chest, and abdominal computed tomography scans
    Lin, Chengxiang
    Shen, Xigang
    Gu, Yajia
    Qiao, Zhongwei
    Peng, Weijun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (06) : 4031 - 4040