Bismuth breast-shield use in chest computed tomography for efficient dose reduction and sufficient image quality

被引:5
|
作者
Ko, Chih-Hsiang [1 ,2 ]
Lee, Shiou-Ping [2 ]
Hsieh, Yi-Chien [1 ,2 ]
Lee, Yuan-Hao [1 ]
Yao, Melissa Min-Szu [1 ,2 ]
Chan, Wing P. [1 ,2 ]
机构
[1] Taipei Med Univ, Wan Fang Hosp, Dept Radiol, 111 Hsing Long Rd,Sec 3, Taipei 116, Taiwan
[2] Taipei Med Univ, Coll Med, Sch Med, Dept Radiol, Taipei, Taiwan
关键词
breast shield; computed tomography scan; image quality; radiation dose; safety; TUBE CURRENT MODULATION; THORACIC CT; FEMALE BREAST; RADIATION-EXPOSURE; MDCT;
D O I
10.1097/MD.0000000000026277
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Radiosensitivity in the breasts increases the risk of carcinogenesis from exposure to the ionizing radiation of computed tomography (CT) administered in the course of medical attention. Bismuth shielding techniques have been used to reduce radiation, but image noise increased, degrading image quality. Purpose: The aim of this study was to investigate how the use of iterative reconstruction (IR) combined with bismuth shielding influences image quality. Materials and Methods: Women aged at least 20 years with body mass indexes <28 were recruited and randomly assigned to 1 of 3 CT scanning protocols without shielding, with a bismuth breast shield before the scout view, or with a bismuth breast shield after the scout view. All obtained images were reconstructed using an IR algorithm. To evaluate radiation dose, 2 Gafchromic films were placed over the clothes, 1 near each nipple. Results: Average dose reduction was significant (27.99%, P < .05) when bismuth shielding was applied after the scout view. Using the contrast-to-noise ratio, the image quality was found to be superior when the IR algorithm was applied. Using quantitative evaluations by 2 radiologists applying a 4-point Likert scale, significant differences in image quality were not found among the 3 protocols. Conclusion: Bismuth breast shields, particularly when used after acquiring scout images, are effective at reducing radiation dose without undermining the diagnostic value of the images when the IR technique is applied.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Trade-off between breast dose and image quality using composite bismuth shields in computed tomography: A phantom study
    Mehnati, Parinaz
    Malekzadeh, Reza
    Hussein, Hussein Ali
    Obaid, Noor H.
    Ebrahimiyan, Saadat
    Sooteh, Mohammad Yousefi
    Refahi, Soheila
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (01) : 145 - 152
  • [22] Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study
    Liao, Ying-Lan
    Lai, Nan-Ku
    Tyan, Yeu-Sheng
    Tsai, Hui-Yu
    BIOMEDICAL JOURNAL, 2019, 42 (05) : 343 - 351
  • [23] Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography
    May, Matthias S.
    Wuest, Wolfgang
    Brand, Michael
    Stahl, Christian
    Allmendinger, Thomas
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 465 - 470
  • [24] Assessment of Commercially Available In-plane Bismuth Breast Shields for Clinical Use in Patients Undergoing Thoracic Computed Tomography
    Karami, V
    Albosof, M.
    Najarian, M.
    Gholami, M.
    HONG KONG JOURNAL OF RADIOLOGY, 2021, 24 (02): : 108 - 115
  • [25] Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography
    van der Bijl, Noortje
    Joemai, Raoul M. S.
    Mertens, Bart J. A.
    de Roos, Albert
    Veldkamp, Wouter J. H.
    Bax, Jeroen J.
    Schuijf, Joanne D.
    Geleijns, Jacob
    Kroft, Lucia J. M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (02): : 453 - 461
  • [26] Multidetector Computed Tomography Chest Examinations With Low-Kilovoltage Protocols in Adults: Effect on Image Quality and Radiation Dose
    Kim, Mi Jung
    Park, Chul Hi
    Choi, Soo Jin
    Hwang, Kyung Hoon
    Kim, Hyung Sik
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 416 - 421
  • [27] Image quality and radiation dose reduction in chest CT in pulmonary infection
    Cristofaro, Massimo
    Rizzi, Elisa Busi
    Piselli, Pierluca
    Pianura, Elisa
    Petrone, Ada
    Fusco, Nicoletta
    Di Stefano, Federica
    Schinina', Vincenzo
    RADIOLOGIA MEDICA, 2020, 125 (05): : 451 - 460
  • [28] Image quality and radiation dose reduction in chest CT in pulmonary infection
    Massimo Cristofaro
    Elisa Busi Rizzi
    Pierluca Piselli
    Elisa Pianura
    Ada Petrone
    Nicoletta Fusco
    Federica Di Stefano
    Vincenzo Schinina’
    La radiologia medica, 2020, 125 : 451 - 460
  • [29] Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality
    Afadzi, Mercy
    Lysvik, Elisabeth Kirkeby
    Andersen, Hilde Kjernlie
    Martinsen, Anne Catrine T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 62 - 68
  • [30] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Cho, Hyun-Hae
    Lee, So Mi
    You, Sun Kyoung
    PEDIATRIC RADIOLOGY, 2020, 50 (02) : 242 - 251