A comparative study between PCR and PLS in simultaneous spectrophotometric determination of diphenylamine, aniline, and phenol: Effect of wavelength selection

被引:112
作者
Hemmateenejad, Bahram [1 ]
Akhond, Morteza [1 ]
Samari, Fayezeh [1 ]
机构
[1] Shiraz Univ, Dept Chem, Shiraz 71454, Iran
关键词
PLS; PCR; comparison; wavelength selection; diphenylamine; degradation;
D O I
10.1016/j.saa.2006.09.014
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Partial least squares (PLS) and principal component regression (PCR) have received considerable attention in the chemometrics for multicomponent analysis where superiority of one over another is a challenging problem yet. Considering the effect of wavelength selection, a comparison was made between PCR and PLS methods by application those to simultaneous spectrophotometric determination of diphenylamine (DPA), a compound from the third European Union list of priority pollutants, and its environmentally related products aniline and phenol. The UV absorbance spectra of the methanolic solutions of the analytes were measured in the concentration ranges of 1.0-10.0 mu g mL(-1) and then subjected to PCR and PLS. The models refinement procedure and validation was performed by cross-validation. A modified changeable size moving windows strategy, where optimized the intervals between the sensors in a selected windows, was also proposed to select the more informative spectral regions for each of the analytes. It was found that wavelength selection improved the quality of predictions for both regression methods whereas more reliable results were obtained by removing of the highly collinear neighboring wavelengths. The resultant data explained that PLS produced more or less better results when whole spectral data were used but in the case of selected wavelength regions both methods produced similar results and no comments could be given about the superiority of one against another. The major difference was obtaining the higher number of factors for PCR, which is not a significant problem. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:958 / 965
页数:8
相关论文
共 35 条
[11]   Reduced PCR/PLSR models by subspace projections [J].
Ergon, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 81 (01) :68-73
[12]   Constrained numerical optimization of PCR/PLSR predictors [J].
Ergon, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 65 (02) :293-303
[13]  
Gallego JML, 2002, ANAL CHIM ACTA, V460, P85
[14]   Rapid determination of diphenylamine residues in apples and pears with a single multicommuted fluorometric optosensor [J].
García-Reyes, JF ;
Ortega-Barrales, P ;
Molina-Díaz, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (26) :9874-9878
[15]   PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL [J].
GELADI, P ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1986, 185 :1-17
[16]   Simultaneous determination of cobalt and nickel. Comparison of prediction ability of PCR and PLS using original, first and second derivative spectra [J].
Ghasemi, J ;
Niazi, A .
MICROCHEMICAL JOURNAL, 2001, 68 (01) :1-11
[17]   Wavelength selection for multivariate calibration using a genetic algorithm: A novel initialization strategy [J].
Goicoechea, HC ;
Olivieri, AC .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2002, 42 (05) :1146-1153
[18]   The problem of overfitting [J].
Hawkins, DM .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2004, 44 (01) :1-12
[19]   Net analyte signal-based simultaneous determination of antazoline and naphazoline using wavelength region selection by experimental design-neural networks [J].
Hemmateenejad, A ;
Ghavami, R ;
Miri, R ;
Shamsipur, M .
TALANTA, 2006, 68 (04) :1222-1229
[20]   Correlation ranking procedure for factor selection in PC-ANN modeling and application to ADMETox evaluation [J].
Hemmateenejad, B .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2005, 75 (02) :231-245