Volatile Organic Compounds Trapping from Gaseous Samples on the Basis of Co-Liquefaction with Organic Solvent for Gas Chromatographic Analysis

被引:2
作者
Djozan, Djavanshir [1 ]
Jouyban, Abolghasem [2 ,3 ,4 ]
Mohammadandashti, Parastou [1 ]
机构
[1] Islamic Azad Univ, East Azerbaijan Sci & Res Branch, Coll Sci, Dept Chem, Tabriz, Iran
[2] Tabriz Univ Med Sci, Pharmaceut Anal Res Ctr, Tabriz, Iran
[3] Tabriz Univ Med Sci, Fac Pharm, Tabriz, Iran
[4] Tabriz Univ Med Sci, Kimia Idea Pardaz Azarbayjan KIPA Sci Based Co, Tabriz 51664, Iran
关键词
Co-liquefaction; air sampling; exhaled breath; volatile compounds; benzene series compounds; organic solvent; SOLID-PHASE MICROEXTRACTION; ON-FIBER-DERIVATIZATION; MASS SPECTROMETRY; AQUEOUS SAMPLES; AIR; WATER; ALDEHYDES; BENZENE; XYLENES; TOLUENE;
D O I
10.2174/1573411013666161108151440
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Volatile organic compounds (VOCs) are emitted from a variety of industrial sources and human exhaled breath with endogenous and exogenous origins. For environmental, health, and scientific studies, these compounds must be monitored at trace levels in airborne, gaseous samples and human breath exhales. This article presents the challenges for developing a simple, rapid, non expensive and adsorbent free method for the isolation and enrichment of volatile organic compounds (VOCs) from gaseous samples on the basis of co-liquefaction of analytes and solvent molecules. Methods: A 500 mL spherical glass device was filled with an air sample or human breath exhaled. 0.5 mL of acetone was introduced and exposed to ultra sonification for cold vaporization and then cooled down at -10 degrees C for co-liquefaction of acetone accompanying with VOCs. Parameters affecting performance of the extraction method were investigated using a mixture of benzene, toluene, ethyl-benzene and xylenes (BTEX) as the model VOCs. For quantitative investigation, 2 mu L of the extract was subject to GC-FID analysis. Results: Under optimal conditions, the method displayed good linearity for BTEX within a range of 0.3-800 ng mL(-1), with correlation coefficients > 0.996. The limits of detection (LODs) and the limits of quantitation (LOQs) ranged from 0.13 to 0.25 ng mL(-1) and 0.3 to 0.85 ng mL(-1), respectively. The relative standard deviations (n= 3) were less than 4.53%. Moreover, enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 1075 to 1296-fold and 86-103%, respectively. The overall time for sampling and extraction is 20 min. Conclusion: A novel enrichment method was provided for extraction of volatile analytes from gaseous samples prior to their gas chromatographic analysis. The method is applicable to analyze samples of environmental and/or toxicological interests.
引用
收藏
页码:393 / 401
页数:9
相关论文
共 31 条
[1]   Development of a gas chromatography-mass spectrometry method for the determination of pesticides in gaseous and particulate phases in the atmosphere [J].
Borras, E. ;
Sanchez, P. ;
Munoz, A. ;
Tortajada-Genaro, L. A. .
ANALYTICA CHIMICA ACTA, 2011, 699 (01) :57-65
[2]   Development of second-generation sample enrichment probe for improved sorptive analysis of volatile organic compounds [J].
Burger, B. V. ;
le Roux, M. ;
Marx, B. ;
Herbert, S. A. ;
Amakali, K. T. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (12) :1567-1575
[3]   Sample preparation for the analysis of volatile organic compounds in air and water matrices [J].
Demeestere, Kristof ;
Dewulf, Jo ;
De Witte, Bavo ;
Van Langenhove, Herman .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1153 (1-2) :130-144
[4]   Development of headspace solid-phase microextraction with on-fiber derivatization for determination of hexanal and heptanal in human blood [J].
Deng, CH ;
Li, N ;
Zhang, XM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :47-52
[5]   Investigation of solid-phase microextraction efficiency using pencil lead fiber for in vitro and in vivo sampling of defensive volatiles from insect's scent gland [J].
Djozan, D ;
Baheri, T ;
Farshbaf, R ;
Azhari, S .
ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) :197-201
[6]   Sorbentless cryogenic needle trap device for the extraction of organic volatile compounds [J].
Djozan, Djavanshir ;
Sorouraddin, Mohammad Hossein ;
Norouzi, Jamal ;
Farajzadeh, Mir Ali .
MICROCHIMICA ACTA, 2012, 177 (1-2) :81-88
[7]   Development and application of needle trap devices [J].
Eom, In-Yong ;
Tugulea, Anca-Maria ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1196 :3-9
[8]   Development of a versatile, easy and rapid atmospheric monitor for benzene, toluene, ethylbenzene and xylenes determination in air [J].
Esteve-Turrillas, Francesc A. ;
Ly-Verdu, Saray ;
Pastor, Agustin ;
de la Guardia, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (48) :8549-8556
[9]  
Fazeli-Bakhtiyari R, 2015, IRAN J BASIC MED SCI, V18, P979
[10]   Sorbent trapping of volatile organic compounds from air [J].
Harper, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :129-151