Three-Point Dixon Method Enables Whole-Body Water and Fat Imaging of Obese Subjects

被引:112
作者
Berglund, Johan [1 ]
Johansson, Lars [1 ,2 ]
Ahlstrom, Hakan [1 ]
Kullberg, Joel [1 ]
机构
[1] Univ Uppsala Hosp, Dept Radiol, SE-75185 Uppsala, Sweden
[2] Univ Uppsala Hosp, Astra Zeneca R&D, SE-75185 Uppsala, Sweden
关键词
three-point Dixon; whole-body MRI; water and fat separation; chemical shift imaging; fat suppression; FIELD MAP ESTIMATION; DECOMPOSITION; SEPARATION; PROTON; IMAGES; IDEAL; MRI;
D O I
10.1002/mrm.22385
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dixon imaging techniques derive chemical shift-separated water and fat images, enabling the quantification of fat content and forming an alternative to fat suppression. Whole-body Dixon imaging is of interest in studies of obesity and the metabolic syndrome, and possibly in oncology. A three-point Dixon method is proposed where two solutions are found analytically in each voxel. The true solution is identified by a multiseed three-dimensional region-growing scheme with a dynamic path, allowing confident regions to be solved before unconfident regions, such as background noise. 2 pi-Phase unwrapping is not required. Whole-body datasets (256 x 184 x 252 voxels) were collected from 39 subjects (body mass index 19.8-45.4 kg/m(2)), in a mean scan time of 5 min 15 sec. Water and fat images were reconstructed offline, using the proposed method and two reference methods. The resulting images were subjectively graded on a four-grade scale by two radiologists, blinded to the method used. The proposed method was found superior to the reference methods. It exclusively received the two highest grades, implying that only mild reconstruction failures were found. The computation time for a whole-body dataset was 1 min 51.5 sec +/- 3.0 sec. It was concluded that whole-body water and fat imaging is feasible even for obese subjects, using the proposed method. Magn Reson Med 63:1659-1668, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1659 / 1668
页数:10
相关论文
共 49 条
[41]   Fat suppression strategies in MR imaging of breast cancer at 3.0 T: comparison of the two-point Dixon technique and the frequency selective inversion method [J].
Wakako Kaneko Mikami ;
Toshiki Kazama ;
Hirotaka Sato ;
Hajime Yokota ;
Takashi Higashide ;
Takuro Horikoshi ;
Ken Motoori ;
Yukimasa Miyazawa ;
Takeshi Nagashima ;
Takashi Uno .
Japanese Journal of Radiology, 2013, 31 :615-622
[42]   Fat suppression strategies in MR imaging of breast cancer at 3.0 T: comparison of the two-point Dixon technique and the frequency selective inversion method [J].
Mikami, Wakako Kaneko ;
Kazama, Toshiki ;
Sato, Hirotaka ;
Yokota, Hajime ;
Higashide, Takashi ;
Horikoshi, Takuro ;
Motoori, Ken ;
Miyazawa, Yukimasa ;
Nagashima, Takeshi ;
Uno, Takashi .
JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (09) :615-622
[43]   Comparison of Gross Body Fat-Water Magnetic Resonance Imaging at 3 Tesla to Dual-Energy X-Ray Absorptiometry in Obese Women [J].
Silver, Heidi J. ;
Niswender, Kevin D. ;
Kullberg, Joel ;
Berglund, Johan ;
Johansson, Lars ;
Bruvold, Morten ;
Avison, Malcolm J. ;
Welch, E. Brian .
OBESITY, 2013, 21 (04) :765-774
[44]   Whole-body MRI in children and adolescents: Can T2-weighted Dixon fat-only images replace standard T1-weighted images in the assessment of bone marrow? [J].
de Horatio, Laura Tanturri ;
Zadig, Pia K. ;
von Brandis, Elisabeth ;
Rosendahl, Karen ;
Avenarius, Derk F. M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
[45]   Non-Contrast-Enhanced Whole-Body Magnetic Resonance Imaging in the General Population: The Incidence of Abnormal Findings in Patients 50 Years Old and Younger Compared to Older Subjects [J].
Cieszanowski, Andrzej ;
Maj, Edyta ;
Kulisiewicz, Piotr ;
Grudzinski, Ireneusz P. ;
Jakoniuk-Glodala, Karolina ;
Chlipala-Nitek, Irena ;
Kaczynski, Bartosz ;
Rowinski, Olgierd .
PLOS ONE, 2014, 9 (09)
[46]   A study on multiple array method of birdcage coils to improve the signal intensity and homogeneity in small-animal whole-body magnetic resonance imaging at 7 T [J].
Heo, Phil ;
Kim, Han-Joong ;
Han, Sang-Doc ;
Kim, Donghyuk ;
Im, Geun Ho ;
Kim, Soobum ;
Kim, Kyoung-Nam .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2020, 30 (01) :31-44
[47]   Comparing T1-weighted and T2-weighted three-point Dixon technique with conventional T1-weighted fat-saturation and short-tau inversion recovery (STIR) techniques for the study of the lumbar spine in a short-bore MRI machine [J].
Brandao, S. ;
Seixas, D. ;
Ayres-Basto, M. ;
Castro, S. ;
Neto, J. ;
Martins, C. ;
Ferreira, J. C. ;
Parada, F. .
CLINICAL RADIOLOGY, 2013, 68 (11) :E617-E623
[48]   Very early indicators of response to systemic therapy in lymphoma patients based on alterations in water diffusivity-A preliminary experience in 20 patients undergoing whole-body diffusion-weighted imaging [J].
Horger, M. ;
Claussen, C. ;
Kramer, U. ;
Fenchel, M. ;
Lichy, M. ;
Kaufmann, S. .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) :1655-1664
[49]   Combined application of isotropic three-dimensional fast spin echo (3D-FSE-Cube) with 2-point Dixon fat/water separation (FLEX) and 3D-FSE-cube in MR dacryocystography [J].
Liu, Ping ;
Wang, Qiuxia ;
Peng, Chengdong ;
Luo, Ban ;
Zhang, Jing .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1094)