Three-Point Dixon Method Enables Whole-Body Water and Fat Imaging of Obese Subjects

被引:112
作者
Berglund, Johan [1 ]
Johansson, Lars [1 ,2 ]
Ahlstrom, Hakan [1 ]
Kullberg, Joel [1 ]
机构
[1] Univ Uppsala Hosp, Dept Radiol, SE-75185 Uppsala, Sweden
[2] Univ Uppsala Hosp, Astra Zeneca R&D, SE-75185 Uppsala, Sweden
关键词
three-point Dixon; whole-body MRI; water and fat separation; chemical shift imaging; fat suppression; FIELD MAP ESTIMATION; DECOMPOSITION; SEPARATION; PROTON; IMAGES; IDEAL; MRI;
D O I
10.1002/mrm.22385
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dixon imaging techniques derive chemical shift-separated water and fat images, enabling the quantification of fat content and forming an alternative to fat suppression. Whole-body Dixon imaging is of interest in studies of obesity and the metabolic syndrome, and possibly in oncology. A three-point Dixon method is proposed where two solutions are found analytically in each voxel. The true solution is identified by a multiseed three-dimensional region-growing scheme with a dynamic path, allowing confident regions to be solved before unconfident regions, such as background noise. 2 pi-Phase unwrapping is not required. Whole-body datasets (256 x 184 x 252 voxels) were collected from 39 subjects (body mass index 19.8-45.4 kg/m(2)), in a mean scan time of 5 min 15 sec. Water and fat images were reconstructed offline, using the proposed method and two reference methods. The resulting images were subjectively graded on a four-grade scale by two radiologists, blinded to the method used. The proposed method was found superior to the reference methods. It exclusively received the two highest grades, implying that only mild reconstruction failures were found. The computation time for a whole-body dataset was 1 min 51.5 sec +/- 3.0 sec. It was concluded that whole-body water and fat imaging is feasible even for obese subjects, using the proposed method. Magn Reson Med 63:1659-1668, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1659 / 1668
页数:10
相关论文
共 28 条
[1]   Chemical shift imaging with spectrum modeling [J].
An, L ;
Xiang, QS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :126-130
[2]  
[Anonymous], P INT SOC MAGN RESON
[3]   Principles of whole-body continuously-moving-table MRI [J].
Boernert, Peter ;
Aldefeld, Bernd .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) :1-12
[4]   Whole-body 3D water/fat resolved continuously moving table imaging [J].
Boernert, Peter ;
Keupp, Jochen ;
Eggers, Holger ;
Aldefeld, Bernd .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) :660-665
[5]   Two-point dixon technique for water-fat signal decomposition with B-o inhomogeneity correction [J].
Coombs, BD ;
Szumowski, J ;
Coshow, W .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :884-889
[6]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[7]   MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :521-530
[8]   3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[9]   Joint estimation of water/fat images and field inhomogeneity map [J].
Hernando, D. ;
Haldar, J. P. ;
Sutton, B. P. ;
Ma, J. ;
Kellman, P. ;
Liang, Z. -P. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :571-580
[10]   Algebraic Decomposition of Fat and Water in MRI [J].
Jacob, Mathews ;
Sutton, Bradley P. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (02) :173-184