Three-Point Dixon Method Enables Whole-Body Water and Fat Imaging of Obese Subjects

被引:111
作者
Berglund, Johan [1 ]
Johansson, Lars [1 ,2 ]
Ahlstrom, Hakan [1 ]
Kullberg, Joel [1 ]
机构
[1] Univ Uppsala Hosp, Dept Radiol, SE-75185 Uppsala, Sweden
[2] Univ Uppsala Hosp, Astra Zeneca R&D, SE-75185 Uppsala, Sweden
关键词
three-point Dixon; whole-body MRI; water and fat separation; chemical shift imaging; fat suppression; FIELD MAP ESTIMATION; DECOMPOSITION; SEPARATION; PROTON; IMAGES; IDEAL; MRI;
D O I
10.1002/mrm.22385
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dixon imaging techniques derive chemical shift-separated water and fat images, enabling the quantification of fat content and forming an alternative to fat suppression. Whole-body Dixon imaging is of interest in studies of obesity and the metabolic syndrome, and possibly in oncology. A three-point Dixon method is proposed where two solutions are found analytically in each voxel. The true solution is identified by a multiseed three-dimensional region-growing scheme with a dynamic path, allowing confident regions to be solved before unconfident regions, such as background noise. 2 pi-Phase unwrapping is not required. Whole-body datasets (256 x 184 x 252 voxels) were collected from 39 subjects (body mass index 19.8-45.4 kg/m(2)), in a mean scan time of 5 min 15 sec. Water and fat images were reconstructed offline, using the proposed method and two reference methods. The resulting images were subjectively graded on a four-grade scale by two radiologists, blinded to the method used. The proposed method was found superior to the reference methods. It exclusively received the two highest grades, implying that only mild reconstruction failures were found. The computation time for a whole-body dataset was 1 min 51.5 sec +/- 3.0 sec. It was concluded that whole-body water and fat imaging is feasible even for obese subjects, using the proposed method. Magn Reson Med 63:1659-1668, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1659 / 1668
页数:10
相关论文
共 49 条
  • [1] Analytical Three-Point Dixon Method: With Applications for Spiral Water-Fat Imaging
    Wang, Dinghui
    Zwart, Nicholas R.
    Li, Zhiqiang
    Schar, Michael
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (02) : 627 - 638
  • [2] Three-point Dixon method with a MISSTEC sequence
    F. Lethimonnier
    F. Franconi
    S. Akoka
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1997, 5 : 285 - 288
  • [3] Three-point Dixon method with a MISSTEC sequence
    Lethimonnier, F
    Franconi, F
    Akoka, S
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1997, 5 (04) : 285 - 288
  • [4] An automated iterative algorithm for water and fat decomposition in three-point Dixon magnetic resonance imaging
    Chen, QS
    Schneider, E
    Aghazadeh, B
    Weinhous, MS
    Humm, J
    Ballon, D
    MEDICAL PHYSICS, 1999, 26 (11) : 2341 - 2347
  • [5] Fat quantification using three-point dixon technique: In vitro validation
    Kovanlikaya, A
    Guclu, C
    Desai, C
    Becerra, R
    Gilsanz, V
    ACADEMIC RADIOLOGY, 2005, 12 (05) : 636 - 639
  • [6] Regularized Iterative Reconstruction for Undersampled BLADE and Its Applications in Three-point Dixon Water-fat Separation
    He, Qiang
    Weng, Dehe
    Zhou, Xiaodong
    Ni, Cheng
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1314 - 1325
  • [7] A three-point Dixon method for water and fat separation using 2D and 3D gradient-echo techniques
    Wang, Y
    Li, DB
    Haacke, EM
    Brown, JJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 703 - 710
  • [8] Noise considerations of three-point water-fat separation imaging methods
    Wen, Zhifei
    Reeder, Scott B.
    Pineda, Angel R.
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2008, 35 (08) : 3597 - 3606
  • [9] Direct water and fat determination in two-point Dixon imaging with flexible echo times
    Rambow, Olen
    Hazle, John
    Clark, John
    Ma, Jingfei
    MEDICAL PHYSICS, 2013, 40 (11)
  • [10] Fat suppression for ultrashort echo time imaging using a single-point Dixon method
    Jang, Hyungseok
    Carl, Michael
    Ma, Yajun
    Jerban, Saeed
    Guo, Tan
    Zhao, Wei
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2019, 32 (05)